Laserfiche WebLink
Boulder County, CO <br />04076151 Pate 6 of 7 <br />CITY OF LOUSIVILLE WASTEWATER TREATMENT PLANT <br />PLANNED UNIT DEVELOPMENT 1ST AMENDMENT <br />LOT 1 LOUISVILLE WASTEWATER TREATEMENT PLANT <br />CASE# PUD-00051 6-2024 <br />WAS Storage Operations Building Elevations Page 6 of 7 <br />EAST ELEVATION <br />1/4" =1'-0" <br />WEST ELEVATION <br />SMOKE ALARM HORN & <br />STROBE WITH SMOKE <br />DETECTORS IN BUILDING <br />WAS STORAGE BLDG TOW <br />5308' - 0" <br />WAS STORAGE BLDG FFE S 5297'-0" <br />WAS STORAGE BLDG FFE <br />5297' - 0" <br />2"/ 92H <br />C5 <br />SIGN <br />"No Storage Allowed" <br />(V <br />SOUTH ELEVATION <br />1/4" =1'-0" <br />S <br />ED <br />U <br />oI <br />i <br />• <br />CV <br />C8) <br />PANIC HARDWARE ON <br />BUILDING EXIT DOORS <br />NORTH ELEVATION <br />0 <br />1 INSULATED METAL ROOF PANELS, TYP. <br />2 INSULATED METAL WALL PANEL 'A' ON PEMB STRUCTURE, TYP. <br />3 HOLLOW METAL DOOR AND FRAME, PAINT, TYP. <br />4 OVERHEAD COILING DOOR, TYP. <br />5 ALUMINUM WINDOW, TYP. <br />6 CONCRETE WALL WITH WATER REPELLENT, RE: STRUCT, TYP. <br />7 SNOW GUARDS <br />8 PREFINISHED GALV METAL GUTTERS, 3" X 5" MIN, AND <br />DOWNSPOUTS, 4" X 4" MIN, WITH CONCRETE SPLASH BLOCKS, <br />TYP. <br />9 PREFINISHED METAL NON -VENTED SOFFIT AND FASCIA <br />PANELS, MATCH ROOFING, TYP. <br />10 CONCRETE SPLASHBLOCK, TYP. <br />11 SHEET METAL CANOPY OVER HM DOOR, RE:7/A4.1 <br />12 PREFINISHED METAL LOUVER, TYP. RE: MECH <br />13 HOLLOW METAL DOOR AND FRAME, PAINT, TYP. <br />14 BOLLARD AT OVERHEAD COILING DOOR JAMBS, RE: CIVIL, TYP. <br />KEYNOTES: <br />NA, Inc. 1319 Spruce Street <br />Boulder, CO 80302 303.444.1951 <br />www.jvajva.com <br />Boulder • Fort Coins • Winter Park <br />Glenwood Springs • Denver <br />Short and Brennan Architects <br />One Broadway, Suite A201 <br />Denver, CO 80203 <br />WAS STORAGE BLDG TOW <br />5308'-0" <br />WAS STORAGE BLDG FFE <br />5297'-0" <br />WAS STORAGE BLDG TOW <br />5308' - 0" <br />WAS STORAGE BLDG Ffth <br />5297' - 0" VIF <br />PANIC HARDWARE ON <br />BUILDING EXIT DOORS <br />ORIGINAL SUBMITTAL - JULY 2. 2024 <br />REV 1 - SEPTEMBER 18, 2024 <br />REV 2 - DECEMBER 4 2024 <br />REVISION DESCRIPTION <br />z <br />W <br />0 <br />0 <br />z <br />DESIGNED BY: CC <br />DRAWN BY: CC <br />CHECKED BY: GS <br />JOB #: 1069.4e <br />DATE: DEC 2024 <br />eOJVA, INC. <br />1- <br />z <br />W <br />MO <br />a >Q <br />I- Ott <br />r1O <br />W MO <br />OU <br />> JJ <br />o<S2 <br />J <br />ID <br />(00 <br />0 <br />J <br />0 <br />U) <br />z <br />0 u) <br />z <br />o <br />wQ <br />OJ <br />WR] W <br />V ! w <br />a Z <br />0 <br />U) m <br />1/4" = 11-0" <br />114" = <br />SHEET NO. <br />A1.2 <br />