Laserfiche WebLink
Boulder County, CO <br />04104510 <br />Page 2 of 13 <br />GRADE PLANE CALCULATION <br />_6A: 5343.15 <br />B: 5342.00' <br />C: 5343.07' <br />CORNER ELEVATION A (HIGHEST): 5343.15' <br />CORNER ELEVATION B (LOWEST): 5342.00' <br />AVERAGE GRADE PLANE: 5342.58' <br />LEVEL 1: 5343.15' <br />THERE IS A DIFFERENCE OF 0001.15' BETWEEN <br />GRADE PLANE CALCULATION AND LEVEL 1 <br />n <br />BURLINGTON NORTHERN SANTA FE RAILROAD <br />0 <br />m <br />r <br />O <br />9 <br />N <br />CO <br />0 <br />L. GRADE ELEV <br />6343.16' <br />n <br />GRADE ELEV <br />6343.16' <br />L"D <br />13'-6"I <br />RED GOLD BOTTLING CORPORATION PLANNED <br />UNIT DEVELOPMENT, 1ST AMENDMENT <br />A\ <br />n <br />15'-0" REAR <br />SETBACK <br />1,-0„ <br />LOT 9, BLOCK 1, COLORADO TECHNOLOGICAL CENTER, FIRST FILING, <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO. <br />CASE # PUD-000519-2024 <br />b <br />M <br />N <br />I ARCHITECTURAL SITE PLAN <br />2 SCALE: 1" = 20'-0" <br />1 <br />ADJACENT PROPERTY <br />481 S. ARTHUR AVE <br />(INDUSTRIAL ZONING DISTRICT) <br />LOT 10 BLK 1 COLORADO TECHNOLOGICAL CENTER <br />146'-10" BUILDING LENGTH <br />ZONE LOT LINE: N 75° 29' 16" E, 198.38' <br />SINGLE STORY BUILDING <br />INDUSTRIAL ZONING DISTRICT <br />0 <br />WATER ENTRY <br />LOT 9 BLK 1 COLORADO TECHNOLOGICAL CENTER <br />WAREHOUSE SPACE; 14,735 SF <br />TOTAL BUILDING GFA: 16,294 SF <br />32'-0" <br />i <br />C <br />ROOFTOP EQUIPMENT <br />ABOVE, IS SCREENED <br />BY PARAPET <br />WAREHOUSE <br />e RESTROOM <br />• TENANT <br />•RESTROOM <br />• <br />TENANT <br />SPACE; <br />1,559 SF <br />/777- <br />FIRE APPARATUS ACCESS <br />HAMMERHEAD PER IFC <br />NO PARKING ALLOWED <br />_ZZZ <br />15 .. <br />ZONE LOT LINE: S 75° 29' 16" W, 191.62' <br />EXISTING SINGLE <br />STORY BUILDING <br />L_ = J <br />I20'-6 .E 114" <br />9 <br />H <br />• <br />GRADE ELEV <br />6347.10 <br />r. 1- L <br />'GRADE ELEV <br />>' 6343.3i' . <br />J. <br />EVC EVC EVR <br />14 TOTALPARRNG SPACES <br />EVI <br />S�4 <br />• <br />• <br />• <br />• <br />• <br />• <br />I <br />• <br />I <br />• <br />• <br />I <br />• <br />• <br />I <br />• <br />• <br />33'-4" <br />L <br />' DETENTION POND RAILING <br />DETENTION POND, <br />REF: GRADING PLAN <br />�. �• FRONT SETBACK <br />I I <br />20�_p�l - PARKING SETBACK <br />��. & TELECOMM. EASTMENT <br />14'-0" UTILITY EASEMENT <br />p 11 • -(4) BIKE SPACES <br />d <br />30'-0" <br />-- <br />• <br />10 <br />I <br />I <br />• <br />• <br />I <br />• <br />• <br />I <br />ADJACENT PROPERTY <br />573 S. ARTHUR AVE <br />(INDUSTRIAL ZONING DISTRICT) <br />LOT 8 BLK 1 COLORADO TECHNOLOGICAL CENTER <br />ZONE LOT LINE: S 14* 29' 48" E, 184.88' <br />j <br />W <br />RZ <br />raft a <br />Q <br />III CID <br />0 <br />Cl) <br />WALL MOUNTED <br />ELECTRICAL METERS <br />- ACCESSBILE ROUTE <br />- PUBLIC ZONE <br />-5'-0" SIDEWALK <br />PAD MOUNTED <br />TRANSFORMER <br />- BOLLARDS <br />SITE ACCESS/\ <br />42'-0" DRIVEWAY CENTERLINES <br />118'-9" BUILDING LENGTH <br />0) <br />24'-0" DRIVE LANE <br />NORTH <br />CURRENT SUBMISSION: PUD AMENDMENT RESUB. #2 <br /># DATE SUBMISSION <br />C 10/20/24 PUD AMENDMENT RESUB. #1 <br />D 03/03/25 PUD AMENDMENT RESUB. #2 <br />BECK ARCHITECTURE, LLC <br />1001 17TH STREET <br />SUITE PL100 <br />DENVER, CO 80202 <br />PH: (303) 466-9665 <br />WWW.BECKGROUP.COM <br />SITE PLAN <br />2 <br />SHEET 2 OF 12 <br />