My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ordinance 1979-660
PORTAL
>
CITY COUNCIL RECORDS
>
ORDINANCES (45.120)
>
1948-1989 Ordinances
>
1979 Ordinances
>
Ordinance 1979-660
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/12/2021 10:15:32 AM
Creation date
4/6/2007 12:18:07 PM
Metadata
Fields
Template:
City Council Records
Doc Type
Ordinance
Signed Date
8/21/1979
Ord/Res - Year
1979
Ord/Res - Number
660
Original Hardcopy Storage
7E2
Supplemental fields
Test
ORD 1979-660
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> - ." <br /> (b) In buildings where more than <br /> one standpipe is provided, they need <br /> not be interconnected. <br /> (c) Piping may be hydraulically <br /> sized. <br /> C. The purpose of smoke control is to restrict movement <br /> of smoke to the general area of fire origin and to maintain means <br /> of egress in a usable condition. <br /> 1. The smoke-control system shall be activated <br /> by operation of either the sprinkler system, smoke <br /> detectors, or may be manually operated, subject to <br /> approval of the building official. Smoke detectors <br /> shall be provided within the return-air portion of <br /> the air condition system as required by the Uniform <br /> Mechanical Code. Smoke detectors which will sound <br /> a local alarm also shall be provided on the tenant <br /> side at openings where open-type security grilles <br /> are used. Actuation of either the duct detector <br /> or the sprinkler system shall cause the air supply <br /> to the air conditioning zone in which the fire occurs <br /> to shut down. During those hours when the air <br /> conditioning system is not operating, smoke detector <br /> or sprinkler actuation will transmit an alarm only <br /> as required in 15.44.040 (A)(l) herein. <br /> 2. The mall shall have smoke-removal capability <br /> installed in or near the roof. Such facility may <br /> be either natural or mechanical. <br /> 3. Before the smoke-control system is accepted <br /> by the building official, it shall be tested in his <br /> presence to confirm that the system is operating in <br /> compliance with the requirements of this subsection. <br /> D. Rooms or areas containing controls for air conditioning <br /> systems, automatic fire extinguishing systems or other detection, <br /> suppression or control elements shall be identified for the use by <br /> the fire department. <br /> E. Each tenant space shall be separate from other tenant <br /> spaces by a wall having a fire-resistive ratio of not less than one <br /> hour. The separation wall shall extend from the floor to the under- <br /> side of the floor or roof above. Except as required by other provisions <br /> of this code, the ceiling need not be a fire-resistive assembly. A <br /> Separation is not required between any tenant space and a mall, except <br /> for occupancy separations required by Section 15.44.060. <br /> F. When a public address system is provided, the system <br /> shall be made accessible to the fire department. <br /> G. Within every story or level and from sidewall to side- <br /> wall of each tenant space or mall, approved plastic panels and signs <br /> shall be limited as follows: <br /> 1. They shall not exceed 20 percent of the wall <br /> area facing the mall; <br /> 2. They shall not exceed a height of 36 inches <br /> except that if the sign is vertical then the height <br /> shall not exceed 96 inches and the width shall not <br /> exceed 36 inches; <br /> 3. They shall be located a minimum distance of <br /> 18 inches from adjacent tenants <br /> 4. All edges and the back shall be fully encased <br /> in metal. <br /> -3- <br />
The URL can be used to link to this page
Your browser does not support the video tag.