Laserfiche WebLink
The building has little or no exterior character and suggests a lack of quality for the golf <br />course as a whole, not just the clubhouse. <br /> The current building design encourages people to use the smaller parking lot, and <br />effectively makes the majority of the onsite parking inconvenient at best. <br /> The front entry is virtually unused (most customers enter the building from one of the <br />two end doors). <br /> The back deck has no shade and in unusable on hot afternoons. <br /> There is no ADA access to the main floor of the building. <br /> The existing bathrooms have no facilities for changing clothes outside of the toilet <br />stalls. <br /> Both the Bar and open cooking area are unattractive and do not encourage people to <br />spend time in the dining room before or after golfing. <br /> There is no place for customers to hold private meetings. <br /> The kitchen is undersized and doesn't have enough storage area. <br />R: <br />ECOMMENDATIONS <br />By working with building stakeholders, we have developed the following general <br />recommendations for renovating this facility: <br /> Relocate the Pro-Shop to the west end of the building and the Dining Room to the east <br />end. <br /> Expand the kitchen into the current Bar area and enclose the existing cooking area. <br /> Expand the existing bathrooms to meet ADA requirements and provide a bench for <br />changing clothes outside of the toilet stalls. <br /> Create a portion of the dining area that can be physically separated from the <br />remainder of the space for private meetings and events. <br /> Create a private deck area directly associated with the new private meeting area. <br /> Create a new Bar area that is more central to the dining area and that provides a <br />functional and decorative centerpiece for that area. <br />Replace the existing canvas front porch covering with a more permanent roof <br />structure. <br /> Add a covered porch to the west end of the building as an entrance to the Pro-Shop. <br /> Create an ADA compliant ramp to both entrances on the main floor of the building. <br /> Expand the existing back deck to include a larger covered deck area. <br /> Expand the lower level cart storage and work areas to include the area currently <br />covered by the rear deck. <br /> Limit significant structural impacts to the existing facility by working with the existing <br />exterior bearing walls and roof forms. <br />To address these issues we have developed the attached schematic plans and exterior <br />renderings. These plans and renderings are schematic in nature and do not represent final <br />design ideas and plan layouts. Care must yet be taken to coordinate with the facility operator <br />to ensure the kitchen, dining, and retail facilities meet their specific needs. Further, field <br />verification of existing plumbing locations, exterior grades, and floor elevations should be <br />evaluated to ensure ADA compliance can be met as illustrated. <br />In these proposed schematic designs, the pro-shop and dining room have switched places <br />and a dedicated entrance for each amenity is now clearly defined in the mass and form of the <br />CCGCCIS <br />September 6th, 2011 <br />OAL REEK OLF OURSE LUBHOUSE MPROVEMENTS UMMARY <br />Lodestone Design Group 3 of 4 <br />Page <br /> <br />