My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Christopher Plaza II Phase I PUD Mylar
PORTAL
>
RECORDED PLATS (Mylars) and CITY MAPS
>
PUD (Planned Unit Developments)
>
C
>
Christopher Plaza II
>
Christopher Plaza II Phase I PUD Mylar
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2019 10:26:56 AM
Creation date
1/13/2017 12:43:41 PM
Metadata
Fields
Template:
CITYWIDE
Also Known As (aka)
Christopher Plaza 2 pka Garden Path
Doc Type
Mylar
Ord/Res - Year
2000
Ord/Res - Number
19
Recordation Number
2119214
Subdivision Name
Christopher Plaza II
Parcel Identification Number
157505428001
Cross-Reference
PC Res 2000-4
PKA Garden Path
Record Series Code
40.180
Record Series Name
Maps Drawings Plats Plans
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SHEET INDEX <br /> P.U.D. SUBMITTAL: <br /> 1 VINITY PLAN, RENDERING, PUD DEVELOPMENT GUIDELINES, SIGNA !I <br /> 2 PUD PLAN, LA SCAPE PLAN, LANDSCAPE LEGEND . <br /> 3 C ELEVATIONS <br /> 4 UTLITY, DRAINAGE & GRADING PLAN <br /> 5 MASTER DRAINAGE PLAN <br /> SUPPLEMENTAL INFORMATION <br /> (a - PHOTOMETRICS <br /> NOTES <br /> I. improvement plans shall be approved by the Public Works Department prior to <br /> construction of public improvements. . <br /> 2. The property owners shall maintain the landscape located within the right-of-way <br /> adjacent to their lot. <br /> 5. Deciduous trees shall not be planted within 5 feet and coniferous trees shall <br /> not be planted within 10 feet of a public sidewalk or utility. <br /> 4. Site lighting shall be provided by means of pole-mounted fixtures and building9 <br /> mounted fi)dures. Building and pole-mounted lighting shall not exceed 24' in Height. <br /> i fixture design, spacing and shielding shall be provided to cut-off effect of <br /> lighting at a6uttin properties,exclusive of shared access easements. Locations <br /> o pore-mounted Fixtures shall be as shown on sheet 2. <br /> 5. All trash enclosures shall be constructed of materials to match the building <br /> architecture, per details on sheet 2. <br /> 6. Ground mounted building identification signage shall be a maximum of 8' long x l8" <br /> high mounted on a base which is 18" above average grade and shall be located <br /> as Indicated on shoot 2. (2) directional signs totaling 5 5F each face shall <br /> be located per details, sheet 2. <br /> 1. See the "Christopher Plaza Ii Subdivision", Lot i, Block I for all property line and <br /> easement information. <br /> S. All landscaping 4 paving, etc., beyond the "Christopher Plaza II Subdivision" area of work <br /> are existing. Locations are approximate. <br /> 41. All existing public and private sidewalk, curb, gutter, and asphalt adjacent to the <br /> perimeter of the site that is cracked , settled,or otherwise damaged shall be <br /> removed and replaced by the contractor,as determined necessary by the City <br /> as part of the project, and at the developer's expense. <br /> <br />PUD DEVELOPMENT GUIDELINES <br /> CHRISTOPIIER PLAZA I SUBDIVISION <br /> ZONING DISTRICT: C-B COMMERCIAL BUSINESS <br /> MAX LOT COVERAGE 40% <br /> MIN SETBACK 30 FEET I5UILDtNG SETBACK <br /> FROM ARTERIAL STREET 25 FEET PARKING SETBACK <br /> MIN SETBACK 10 FEET BUILDING 4 PARKING SETBACK <br /> FROM INTERIOR LOT LINE <br /> OR PRIVATE DRIVE <br /> MAXIMUM ALLOWABLE HEIGHT 35 FEET (PER GDDSG.) <br /> 42 FEET TO TOP OF ROOFED MECHANICAL SCREENS <br /> PROPOSED BUILDING HEIGHT: 30 FEET ABOVE GRADE (TO PEAK OF SLOPED ROOF) <br /> MIN. LOT AREA READ. 1,000 50 FT <br /> ORIGINAL SITE AREA 42,612 50 FT(2.14 ACRES t) <br /> OPEN SPACE DEDICATION (12%) 11,344 50 FT (.26 ACRES) - PER PLAT <br /> BUILDABLE SITE 81,218 50 FT (1.61 ACRES t) <br /> PROPOSED OFFICE PARCEL (PHASE I) SUMMARY: <br /> SITE SUMMARY: <br /> SITE AREA 44,322 50 FT (1.02 ACRES) <br /> OPEN SPACE 35% (15,348 50 FT) <br /> BLDG, PKG 4 DRIVEWAY 65% (26,424 50 FT) <br /> PARKING SUMMARY: <br /> PARKING PROVIDED: 56 PARKING SPACES (INC 2 HANDICAP SPACES) <br /> PARKING REQUIRED: 51 TOTAL PARKING SPACES REQUIRED BASED <br /> ON 4,0 PARKING/1,000 5Q FT OF OFFICE SPACE <br /> AND 6.0 PARK IG/I p00 SQ FT OF MED/DENTAL <br /> BUILDING SUMMARY: <br /> LOWER LEVEL 6,500 50 FT t <br /> SECOND LEVEL 6,500 50 FT t <br /> TOTAL: IQ;5O0 SQ FT OFFICE <br /> 2,500 50 FT MED/DENTAL <br /> PROPOSED BUILDING USE: PROFESSIONAL OFFIC..1„,4 MED/DENTAL OFFICE <br /> PROPOSED RETAL PARCEL (PHASE N) SUMMARY:' ,.: • <br /> 5I TE SUMMARY: <br /> SITE AREA 36,846 50 FT (.$5 ACRES) <br /> OPEN SPACE MIN: 30% (TOTAL 5I TE) = 1,438 50 FT (.17 ACRES) <br /> BLDG/PKG/DRIVEWAY MAX. 10% (TOTAL SITE) = 24,458 50 FT (.b8 ACRES) <br /> PROPOSED BUILDING USE: RETAIL/RESTAURANT(POSSIBLE 4FFI
The URL can be used to link to this page
Your browser does not support the video tag.