My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Building Code Board of Appeals Agenda and Packet 2017 03 16
PORTAL
>
BOARDS COMMISSIONS COMMITTEES RECORDS (20.000)
>
BUILDING CODE BOARD OF APPEALS
>
2000-2019 Building Code Board of Appeals Agendas and Packets
>
2017 Building Code Board of Appeals Agendas and Packets
>
Building Code Board of Appeals Agenda and Packet 2017 03 16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 2:00:21 PM
Creation date
3/17/2017 2:13:59 PM
Metadata
Fields
Template:
City Council Records
Doc Type
Boards Commissions Committees Records
Supplemental fields
Test
BCBOAPKT 2017 03 16
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
181115 trig ioN Sections info -3305 <br />shall have walls eiid Bonita- of one-hour fire -resistive con- Stairs <br />etruct1ari. Where there is enclosed usable apace under stair- (Clont'd.) <br />ways of wood or unprotected metal, the Softs of the stairs <br />shall be protected as required for one-hour fire -resistive <br />construction. <br />(J) Stairway C onshr tioit—ExterIer. Exterior d&ire shall <br />be of incamhuatible material except that on buildings not <br />exceeding two stories in height they may be or wood not <br />less than two inches (2") in nominal thlckneee, <br />(k) Stairway to Roof. In every building more than two <br />atorlea in height, one stairway shall extend to the roof Sur- <br />face unless the roof hus e. slop greater than four in delve. <br />(1) fesalroom. Every required stairway ,Shah have head- <br />room clearance of not less than six feet bix inches [6'8"l <br />measured vertically from the nearest nosing to the nearest <br />soffit. <br />See. 9.°108, (a) General. A ramp conforming to the require- Ramps <br />menta of this Section may be used as an exit. <br />(b) Width. The width of ramps shall be an required for <br />corridors. <br />(c) Slope. The elope of e. ramp shall nut exceed one in <br />eight. <br />(d) Handrails. A ramp with elope exceeding one in ten <br />shall have handrails as required for stairways. <br />(e7 Construction. Ramps shall be constructed as required <br />for stairways. <br />(1) Surface. The surface of ramps shall be roughened or <br />Shall be of non -slip material. <br />See, 8307. {a) Reinoltion. A "horizontal exit" ie e. horn- Horizontal <br />zontal passageway or ramp into another building or into Exits <br />another eectian of the same building through a "One -Hour <br />Fire -Resistive Occupancy Separation." <br />(b) Used as n Required Exit. If conforming to the pro- <br />visions of this Chapter. a horizontal exit may be considered <br />as a required exit. <br />(c) Illecharge AreaK9. A horizontal exit shall lead into a <br />fling area raving capacity for an oceliparit load not less <br />than the occupant load nerved by such exit. The capacity <br />shall be determined by allowing three square feet to aq. ft.) <br />of net clear floor area per occupant. The area into which the <br />horizontal exit leads shall be provided with exits e.e required <br />by Section 3302, at least one of which ellen lead directly to <br />a public way. <br />Sec. 9308. (a) General.: Every interior atairway. ramp, or ,Exit <br />escalator shall be enclosed as specified in this Section. Enclosures <br />EXCEPTIONS; 1. In occupancies other than Group D, <br />an enclosure will not be required for v. atslrws.y, ramp, or <br />22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.