Laserfiche WebLink
EXTG ASPHALT ROOF <br />EXTG VINYL SIDING <br />NO MODIFICATIONS <br />THIS AREA <br />GAS FP VENT <br />-------------- <br />l <br />12x12 <br />EXISTING STRUCTURE <br />PXF,TINE E)TRUC-TU P <br />12x12 <br />12x12 <br />EXISTING STRUCTURE <br />EXTS EXTS <br />30x60 30x60 <br />• <br />3 <br />0 <br />.22 )0c' <br />JOU( : <br />12x12 <br />12x12 <br />12x12 <br />1 <br />+I <br />NEW SOFFIT, FASCIA, SIDING 4 TRIM <br />ON 3 5IDE5 OF EXTG GABLE. <br />NEW SOFFIT 4 FASCIA ON <br />EXTG STRUCTURE <br />THIS ELEVATION ONLY <br />SIGNAGE <br />EIFS <br />ASPHALT ROOF, MATCH EXTG <br />TYP <br />REMOVE EXTG VINYL SIDING / TRIM, TYP. <br />3/4" PINE SHIP LAP SIDING, <br />PRIMED BOTH SIDES AND PAINT <br />MATCH EXPOSURE TO EXTG VINYL <br />TYP <br />2x4 ROUGH CEDAR CORNER BOARDS <br />TYP <br />COPPER FLASH ABV <br />ROUGH 2x10 CEDAR <br />BAND BOARD TYP <br />SIERRA -PACIFIC BRAND WINDOWS; <br />AWNING OPERATION WHERE INDICATED <br />ALU EXT, FIR INT <br />TYP. <br />ALIGN WIN HEAD <br />w/ 1' DOOR HEAD <br />L <br />Qs <br />EXISTING STRUCTURE <br />PROPOSED ENCLOSED ADDITION <br />PROPOSED COVERED PORCH <br />"IMO -O <br />MAIN LEVEL SUS FL <br />6'-8. <br />TOP FND WALL VIF <br />�I• <br />STAIR AND RAIL; SEE DETAIL 6/A500 <br />PROPOSED ENCLOSED ADDITION <br />EXISTING STRUCTURE <br />EXISTING STRUCTURE <br />NORTH ELEVATION <br />SGALE; 1/4"=1"0" <br />COPPER FLASH ABV <br />2" BUFF SANDSTONE VENEER <br />TYP <br />100'-O" <br />MAIN LEVEL SU <br />/'36x36 \ <br />PROPOSED COVERED PORCH <br />PROPOSED ENCLOSED ADDITION <br />WEST ELEVATION <br />SGALE; I/4"= I "O" 1300 <br />TOP FND WALL VIF <br />EXTG VINYL SID INS <br />NO MODIFICATIONS <br />THIS AREA <br />NOTICE : DIM OF COOPERATION <br />Release of these plans contemplates further <br />cooperatlon among the owner, his contractor <br />and the architect. Design and construction are <br />complex. Although the architect and his <br />consultants have performed their services with <br />due care and diligence, they cannot guarantee <br />perfection. Communication TS Imperfect and <br />every contingency cannot be anticipated. Any <br />amblqul or discrepancy discovered by the <br />use of ese pians shaltbe reported <br />Immediately to the architect. Failure to notify <br />the architect compounds misunderstanding and <br />Increases construction costs. A fallure to <br />cooperate by.a simple notice to the architect <br />shall relieve Ito architect from responsibility <br />for all consequences. Changes made from the <br />plans without consent of the architect are <br />unauthorized and shall relieve the architect of <br />responsibility for all consequences arriving out <br />of such changes. <br />All design, documents and data prepared by <br />Verbeck Design Studios INC as instruments of <br />service shall remain the property of Verbeck <br />Design Studios INC and shall notbe copied, <br />changed or disclosed In any form whatsoever <br />without first obtainingthe express written <br />consent of Verbeck-Design Studios INC <br />© Verbeck Design Studios INC <br />N <br />Z <br />0 <br />N <br />uj9 <br />W <br />C <br />O <br />z <br />DESCRIPTION <br />ti <br />o <br />Cns (t) <br />c0 <br />coC7 <br />W <br />G <br />C°111 <br />JOB NOS 12003 <br />DATE. SEPT 24 2012 <br />DRAWN. LV <br />CHECKED. LV <br />DRAWING PHASE <br />PUD <br />SHEET TITLE <br />NORTH 4 WEST ELEVATION; <br />SHEET NUMBER <br />A300 <br />