Laserfiche WebLink
LOT I7 <br />VICINITY MAP <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />EMPLOYEE - <br />BREAK AREA <br />EXISTING <br />TRASH REG. <br />11 (STING PARKING SPADES <br />POLE MOUNTED <br />LIGHT FIXTURE <br />INNOMM <br />gaff ..~AWOMPig: <br />DOCK <br />1A <br />N.T.S. <br />LOT 2 <br />BUILDING SUMMARY <br />PROPOSED USE <br />NUMBER OF STORIES <br />MAXIMUM HEIGHT OF BUILDING <br />ARCHITECTURAL MATERIALS <br />TRIM <br />ROOF <br />DOORS AND WINDOWS <br />NOTE: THIS ADDITION SHALL COMPLY WITH <br />OFFICE/MANUFACTURING/WAREHOUSE <br />ONE (TWO @ EXISTING BLDG) <br />28'-0" <br />CONCRETE TILT WALL, PAINTED <br />METAL, PAINTED <br />SINGLE PLY MEMBRANE - BALLASTED <br />STEEL, ALUMINUM STOREFRONT <br />ALL IDDSG REQUIREMENTS PERTAINING <br />TO ROOFTOP MECHANICAL UNIT SCREENING <br />PARKING SPACES <br />Existing - required <br />Proposed -required <br />Total required <br />Existing Provided <br />Proposed Provided <br />Total Provided <br />PARKING SUMMARY <br />office manf. <br />4,884 s.f. 5,445 s.f. <br />6,860 s.f. <br />4,884 s.f. 12,305 s.f. <br />Available future parking spaces (in <br />addition to <br />warehouse <br />5,445 s.f. 32 spaces <br />6,860 s.f. 28 spaces <br />12,305 s.f. 60 spaces <br />24 spaces <br />(2 H.C. + 37) 39 spaces <br />63 spaces <br />63 provided) 17 spaces <br />* Parking calculations based on: 1:250sf office, 1:500sf manf, 1:1,000sf warehouse <br />or a minimum of 1:500sf for the entire building. <br />* Future parking to be developed as required by subsequent interior tenant finish. <br />S09°59'15_'E 210:4_2' <br />DRAINAGE EASEMENT <br />— — cn <br />LOT I6 <br />.Q8 ACRES <br />EXISTING BUILDING <br />1ST FL 2ND FL <br />OFFICE 2,432 2,452 <br />MANUFACTURING 5,445 <br />WAREHOUSE 5,445 <br />TOTAL <br />13$22 2,432 <br />'1 EXISTING PARKIN& SPACES <br />/. <br />/ <br />// <br />//REPLACE,,/, <br />EXISTING ;"'XISTING, ; <br />ASPHALT ;" ASPI ' LT `r HALT <br />POLE MOUNTED /" <br />//(SEE'G VfGk <br />LIGHT FIXTURE � <br />cri <br />t; <br />3 SPCS 01'-0" <br />SITE SUMMARY <br />LEGAL DESCRIPTION <br />Know all men by these presents, that the undersigned being the owner of a tract <br />of land SW 1/4 of Section 16, T1 S, R69W, 6th principal meridian, City of Louisville, <br />State of Colorado, and being more particularly described as follows: <br />LOTS 15 & 16, 1st FILING, COLORADO TECHNOLOGICAL CENTER, LOUISVILLE, COLORADO <br />TOTAL LOT AREA 45,366 S.F. + 42,575 S.F. = 87,941 S.F. 100.00% <br />TOTAL BUILDING COVERAGE <br />Existing <br />Proposed <br />Combined Total <br />DRIVEWAY & OTHER HARD SURFACE AREA <br />Existing <br />Proposed <br />Combined Total <br />LANDSCAPED AREA <br />Existing <br />Proposed <br />Combined Total <br />ZONING CLASSIFICATION <br />CURRENT USE <br />210.42' <br />14,262 S.F. <br />13.720 S.F. <br />27,982 S.F. <br />12,995 S.F. <br />23.337 S.F. <br />36,332 S.F. <br />31.6% <br />FINAL P.U.D. SU3 <br />CERTIFICATES <br />v <br />PLANNING COMMISSION CERTIFICATE <br />APPROVED THIS 1 DAY OF Di..eem.v', <br />COMMISSION OF THE CITY OF LOUISVILLE, COLORADO <br />RESOLUTION 4t ,SERIES <br />BY <br />CIR <br />BY <br />SECRETARY <br />ITTAL <br />2001, BY THE PLANNING <br />CITY COUNCIL CERTIFICATE <br />41.4% <br />APPROVED THIS I b DAY OF OAL✓ , 20i,YTHE CITY COUNCIL <br />,Z <br />OF THE CITY F LOUISVILLE, COLORADO. RESOLUTION , SERIES <br />°zoD . <br />12,343 S.F. <br />11.438 S.F. <br />23,761 S.F. 27.0% <br />I - INDUSTRIAL <br />OFFICE/WAREHOUSE/MANUFACTURING <br />POLE MOUNTED <br />LIGHT FIXTURE <br />10 FUitURE f��RKIN& <br />POLE MOUNTED <br />LIGHT FIXTURE <br />11111,I11111(11111.11.1.1 ii(iiiiiiuiisn <br />//' /. <br />j: / <br />POLE MOUNTED <br />LIGHT FIXTURE <br />1'1'-6" 10 <br />12 3PCS ®4'-O" <br />1 <br />1 <br />1 <br />1 <br />-0" <br />1 <br />POLE MOUNTED <br />LIGHT FIXTURE <br />5333 <br />FIRE <br />HYDRANT <br />9 <br />5337 <br />5331 <br />0 <br />EXISTING 8" W/ <br />N06°21'50"W <br />Id 0b"21'50" W <br />O <br />EXIST. 27" ST/ @ 0.43% 0 2T'550"W <br />210.00' <br />EXISTING 8" S/L <br />PIERCE STREET <br />1824.20' <br />Ul <br />0 <br />(60' R.O.W.) <br />23'-0" <br />STORM SEWER <br />INLET <br />SITE PLAN <br />N %ALE In = 20'-0" <br />(0 <br />03 <br />co <br />LOT 14 <br />1 <br />0 <br />03 <br />1 in <br />Do <br />1 <br />1 <br />1 <br />1 <br />ELECTRIC <br />SERVICE BOX <br />T <br />BY �AYOR-4L�M <br />BY <br />CITY CLERK <br />CLERK & RECORDER CERTIFICATE <br />COUNTY OF BOULDER) <br />STATE OF COLORADO) <br />I HEREBY CERTIFY THAT THIS INSTRUM <br />O'CLOCK, _ M., THIS <br />AND IS DULY RECORDED IN PLAN FILE <br />035133�� . FILM NO. <br />EUT WAS FILED I MY OFFICE AT <br />DAY OF , 20(n,' <br />,FEE , PAID <br />, RECEPTION NO. <br />RECORDER <br />DEPUTY <br />-this Pot Was i vlatiVer4t cIt ✓poi- rteoitekI. When, i' waS a p,fwV-teC '�► 2a°1 <br />BY SIGNING THIS PUD, THE OWNER ACKNOWLEDGES AND ACCEPTS ALL THE <br />REQUIREMENTS AND INTENT SET FORTH IN THIS PUD. <br />Witness our hands and seals this % day of <br />rk-/7 <br />OWNER <br />ITARY <br />C(9-72:6‘ jci,÷41474 71PC;;;; <br />PROJECT DIRECTORY <br />OWNER <br />200 <br />OWNER: PF INVESTMENTS, LLC - RICK PEASE, DAVID FRIEDLANDER <br />637 S. PIERCE ST., LOUISVILLE, CO 80027 <br />303 665-1305 <br />CIVIL <br />ENGINEER: <br />ELECTRICAL <br />ENGINEER: <br />LANDSCAPE <br />ARCHITECT <br />PARK ENGINEERING CONSULTANTS - DONALD PARK, P.E. <br />420 21ST AVE. STE 101, LONGMONT, CO 80501 <br />303 651-6626 <br />RG ENGINEERING CONSULTANTS - WALTER RABINOVICH <br />75 SO. MADISON ST., STE 100, DENVER, CO 80209 <br />303 355-5534 <br />SCHOLZ LANDSCAPE DESIGN - TRINA SCHOLZ_ <br />42 ARROWLEAF CT., BOULDER, CO 80304 <br />303 447-3489 <br />SHEET INDEX <br />site <br />elevs <br />Iscpg <br />e-1 <br />Utility Plan <br />Grading and drainage plan <br />Site plan <br />Building elevations <br />Landscaping plan <br />Site lighting plan and photometric study <br />Utility plan <br />Grading and drainage plan <br />gYf <br />NOTICE: DUTY OF COOPERATION <br />Release of these plans contemplates <br />further cooperation among the owner, his <br />contractor and the architect. Design and <br />construction are complex. Although the <br />architect and his consultants have <br />performed their services with due care and <br />diligence, they cannot guarantee perfection. <br />Communication is imperfect, and every <br />contingency cannot be anticipated. Any <br />ambiguity or discrepancy discovered by the <br />use of these plans shall be reported <br />immediately to the architect. Failure to <br />notify the architect compounds <br />misunderstanding and increases <br />construction costs. A failure to cooperate <br />by a simple notice to the architect shall <br />relieve the architect from responsibility for <br />all consequences. Changes made from the <br />plans without consent of the architect are <br />unauthorized, and shall relieve the architect <br />of responsibility for all consequences <br />arriving out of such changes. <br />0 <br />z <br />0 <br />z <br />Q <br />0 <br />'*"i. <br />V <br />CZ's► cji <br />WO • <br />O <br />hcui <br />N <br />0 <br />ROBERT <br />ROSENTHAL <br />ARCHITECT <br />1722 14th Street, Ste 200 <br />Boulder, CO 80302 <br />(p) 303 545-5500 <br />(fx) 303 545-0141 <br />JOB NO: 0105 <br />DRAWN: br,mp <br />CHECKED: br <br />DATE: 10-16-01 <br />REVISED: 12-03-01 <br />12-12-01 <br />