LAND USE SUMMARY
<br />ZONING
<br />TOTAL NO. OF UNITS
<br />BUILDING COVERAGE
<br />PAVEMENT COVERAGE
<br />LANDSCAPE COVERAGE
<br />TOTAL LOT AREA
<br />F.A.R.
<br />BUILDING HEIGHT
<br />1
<br />22.8%
<br />40.9%
<br />36.3%
<br />52,344 S.F.
<br />1 : 0.325
<br />43 FEET (TO ROOF PEAK)
<br />32 FEET (TO TYPICAL PARAPET)
<br />BUILDING AREA:
<br />LOWER LEVEL (FOOTPRINT) 11,968 S.F.
<br />UPPER LEVEL 5,032 S.F.
<br />TOTAL 17,000 S.F.
<br />PARKING
<br />OVERALL BUILDING = 17,000 S.F.
<br />35% OFFICE = 5,950 S.F. @ 1 SPACE/250 S.F. = 23.8 SPACES
<br />65% R&D/MANUF. =11,050 S.F. @ 1 SPACE/500 S.F. = 22.1 SPACES
<br />100%
<br />TOTAL PROVIDED PARKING INCLUDING 2 HANDICAP = 49 SPACES
<br />(14% OF TOTAL PROVIDED PARKING ARE COMPACT, 86% ARE FULL SIZE AND HANDICAP)
<br />AVERAGE PARKING RATIO = 49/17000 = 2.88 SPACES/1000 S.F.
<br />NOTES
<br />LOT 8, BLOCK 2
<br />COLORADO TECHNOLOGICAL CENTER, FIRST FILING
<br />PLANNED UNIT DEVELOPMENT
<br />LOCATED IN SECTION 16, TOWNSHIP 1 SOUTH, RANGE 69 WEST, OF THE 6TH P.M.
<br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO
<br />1. DEVELOPMENTS IN THE COLORADO TECHNOLOGICAL CENTER (CTC) ARE ON A SOLE SOURCE
<br />SUPPLY LINE FOR WATER. THOSE LOCATING IN THE PARK ARE SUBJECT TO INTERRUPTIONS OF
<br />SERVICE IN CASE OF EMERGENCY OR UNAVOIDABLE MAINTENANCE ACTIVITIES THAT AFFECT THE
<br />SOLE SOURCE FEED TO THE CTC.
<br />2. DEVELOPMENTS IN THE CTC ARE ON A SOLE SOURCE SUPPLY LINE FOR WATER WHICH MAY, IN
<br />THE NEAR FUTURE, BE INADEQUATE TO MEET DEMAND DURING TIMES OF PEAK USAGE WITHIN THE
<br />CTC.
<br />3. NO DECIDUOUS TREES SHALL BE PLANTED WITHIN FIVE (5) FEET OR CONIFEROUS TREES WITHIN
<br />TEN {10) FEET OF A PUBLIC UTILITY OR SIDEWALK.
<br />4. THE PROPERTY OWNER SHALL REPLACE ALL EXISTING CURB AND GUTTER THAT HAS SETTLED
<br />OR IS OTHERWISE DAMAGED ADJACENT TO THE SITE.
<br />5. TRENCHES WITHIN CHERRY STREET AND ARTHUR AVENUE WILL NEED TO BE FILLED WITH
<br />FLOWABLE FILL MATERIAL.
<br />6. ALL CONNECTIONS TO THE EXISTING UTILITIES SHALL BE DONE IN A MANNER TO MINIMIZE
<br />DISRUPTIONS TO EXISTING USERS.
<br />7. ROOFTOP MECHANICAL UNIT CRITERIA:
<br />a. ROOFTOP MECHANICAL UNITS SHALL BE EFFECTIVELY SCREENED, SETBACK A MINIMUM OF 20
<br />FEET FROM THE ADJACENT BUILDING WALL OR FULLY SCREENED WITH OTHER DESIGN OPTIONS
<br />SUCH AS ROOFTOP PARAPETS.
<br />b. ALL RTUs THAT ARE NOT FULLY SCREENED BY THE BUILDING PARAPET OR
<br />OTHER APPROVED BUILDING ELEMENT SHALL BE PAINTED TO MATCH THE
<br />ADJACENT EXTERIOR BUILDING WALL.
<br />c. RTUs THAT EXTEND ABOVE THE PARAPET AND ARE NOT ENTIRELY SELF-
<br />CONTAINED, 'CLEAN' BOX UNITS (AS DETERMINED BY STAFF), SHALL BE
<br />SCREENED TO THEIR FULL HEIGHT BY AN ARCHITECTURALLY INTEGRATED
<br />SCREENING MATERIAL TO BE SPECIFIED AND APPROVED ON THE PUD.
<br />d. RTUs THAT EXTEND MORE THAN TWO FEET ABOVE THE PARAPET, REGARDLESS
<br />OF RTU DESIGN OR COLOR, MAY BE REQUIRED TO BE SCREENED, SUBJECT TO STAFF
<br />DETERMINATION BASED ON THE DESIGN OF THE UNIT AND THE POTENTIAL VISUAL EXPOSURE
<br />FROM ADJACENT STREETS AND PRIVATE PROPERTY.
<br />8. NO INDIVIDUAL TENANT FINISH PERMITS NOR CERTIFICATES OF OCCUPANCY WILL BE ISSUED
<br />THAT WOULD HAVE A PARKING DEMAND GREATER THAN THE AVERAGE PARKING RATIO PROVIDED
<br />ON THE SITE, EXCEPT AS PROVIDED FOR IN NOTE #9.
<br />9. ON AN INDIVIDUAL TENANT FINISH BASIS, WHEN OVERHEAD LOADING DOORS ARE REMOVED
<br />AND DEFERRED PARKING SPACES ARE MADE AVAILABLE, THOSE PARKING SPACES MAY BE
<br />APPLIED TOWARD THE REQUIRED PARKING OF THAT TENANT ONLY TO INCREASE THE AVERAGE
<br />PARKING RATIO FOR THAT SPACE.
<br />10. GROUND SIGN LIGHTING IS LIMITED TO GROUND -MOUNTED, 100 -WATT METAL HALIDE LIGHTING.
<br />sr.my_ 4?
<br />11.
<br />II
<br />VICINITY MAP
<br />INDEX OF SHEETS
<br />PUD -1
<br />PUD -2
<br />PUD -3
<br />PUD -4
<br />PUD -5
<br />PUD -6
<br />PUD -7
<br />TITLE SHEET
<br />PUD PLAN
<br />GRADING & DRAINAGE PLAN
<br />LANDSCAPE PLAN
<br />LANDSCAPE DETAILS
<br />BUILDING ELEVATIONS
<br />PHOTOMETRIC STUDY
<br />I
<br />LEGAL DESCRIPTION
<br />A PART OF SECTION 16, TOWNSHIP 1 SOUTH, RANGE 69 WEST, 6TH PRINCIPAL MERIDIAN, CITY OF
<br />LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO, DESCRIBED AS FOLLOWS:
<br />LOT 8, BLOCK 2
<br />COLORADO TECHNOLOGICAL CENTER, FIRST FILING
<br />CONTAINING 52,344 SQUARE FEET, MORE OR LESS.
<br />PLANNING COMMISSION CERTIFICATE
<br />APPROVED THIS ' 4/1
<br />LOUISVILLE, COLORADO.
<br />RESOLUTION NO 6 Co
<br />CHAIRMAN
<br />DATE OF NO Very)/S612 , '2080' BY THE PLANNING COMMISSION OF THE CITY OF
<br />SERIES
<br />CITY COUNCIL CERTIFICATE
<br />APPROVED THIS 'i 41)
<br />COLORADO.
<br />RESOLUTION NO
<br />la)" .-....49/ehal
<br />MAYOR
<br />DATE OF Jf!.i4 tL 9i /
<br />, 2000 BY THE CITY COUNCIL OF THE CITY OF LOUISVILLE,
<br />CLERK AND RECORDER CERTIFICATE
<br />COUNTY OF BOULDER)
<br />STATE OF COLORADO)
<br />I HEREBY CERLIFY THAT THIS INSTRUIKENT WAS FILED IN MY OFFICE AT ; OS O'CLOCK M.,
<br />THIS s 5 DAY OF rI / , 2000, AND IS RECORDED IN PLAN FILE
<br />FEES:1200CD PAID 70.00 ASO 4!-ti•e95,,A4z2jTcp.et so, 3/
<br />FILM NO. RECEPTION NO. ow 3c1' 7.26
<br />Liar fad g®usZon
<br />RECORDER
<br />OWNERSHIP SIGNATURE BLOCK
<br />BY SIGNING THIS PUD, THE OWNER ACKNOWLEDGES AND ACCEPTS ALL THE REQUIREMENTS AND INTENT SET FORTH
<br />IN THIS PUD.
<br />WITNESS OUR HANDS AND SEALS THIS
<br />OWNER
<br />/ ..
<br />d'
<br />NOTARY U
<br />3
<br />JO ANNE YANCEY
<br />-NOTARY PUB,LIO
<br />STATE OF COLORADO
<br />My Commission Expires Feb. 24, 2004
<br />DAY OF ,,/'�� , 2000.
<br />IFutura Engineering Inc.
<br />Engineering Consultants and Surveyors
<br />12741 E. Coley Ave., Suite 126
<br />Englewood, Colorado 80111 — (303) 649-9292
<br />FAX (303) 649-9499
<br />8 8 8 8 8
<br />8 s ¢ 8 a
<br />0
<br />z
<br />0
<br />F
<br />U
<br />PG
<br />F
<br />z
<br />0
<br />a
<br />oemaad
<br />Drawn
<br />Checked
<br />Reviewed
<br />Date
<br />DMP
<br />06/17/99
<br />Preheat No.
<br />99-061.01
<br />Draft, No.
<br />PUD -1
<br />1 of 7
<br />AI I
<br />r
<br />w
<br />cox
<br />NO 1NIdd 10 3OG11 NOIIISOd
<br />dV9L0 tl38WflN A8 8308038
<br />POSITION EDGE OF PRINT ON THIS LINE
<br />a
<br />•
<br />ElV9LO 83816111N AG 830803E1
<br />8VGL0 H38Wf1N A8 E00E1038
<br />NOIIVdId1100 OIOH NVId
<br />VINH0311V0 '3NIAdl
<br />NOIIVUOdd00 010H NVId
<br />VINH0311V0 '3NIA111
<br />NOIlVUOdU00 O10H NV -1
<br />•
<br />m:
<br />r
<br />O
<br />z
<br />LB8VI(1N JNIMVUO
<br />O
<br />V
<br />UR8LN(lN ONIM 10
<br />
|