Laserfiche WebLink
SEED MIX <br />COLORADO NATIVE MIX <br />30% Western lAlheatgrass <br />25% Slender Wheatgrass <br />15% Blue Grama <br />10% Buffalograss <br />IO% Arizona Fescue <br />5% Canada iAlildrye <br />5% Sherman Big Bluegrass <br />ROOKY MOUNTAIN INILDFLOI^ER MIX <br />II% Cornflower <br />II% Blackeyed Susan <br />II% Bobo breath <br />IO% African Daisy <br />5% Blue Flax <br />5% Sweet Alyssum <br />5% California Poppy <br />5% Hall Flower <br />5% Prairie Con f o <br />5% Plains Coreopsis <br />4% Garland Chrys humum <br />4% Perennial Gs lardia <br />3% Annual Go' ardia <br />3% Sweet Willaim <br />3% Shasta Daisy <br />2% Corn poppy <br />2% Catchfly <br />2% Rocky Mtn. Penstemon <br />2% Spurred Snapdragon <br />2% Purple Coneflower <br />Annual <br />Biennial <br />Annual <br />Annual <br />Perennial <br />Perennial <br />Tender Perennial <br />Biennial <br />Perennial <br />Annual <br />Annual <br />Perennial <br />Annual <br />Perennial <br />Perennial <br />Annual <br />Annual <br />Annual <br />Annual <br />Perennial <br />Blue <br />Yellow <br />White <br />Orange/salmon/white <br />Blue <br />Orange <br />Ye low <br />Ye low <br />Ye low/maroon <br />Ye Io/white <br />Ye low/red <br />Ye low/red <br />Pink/red/white <br />white <br />White/pink/red <br />Pink <br />Blue <br />Pink/yellow <br />Purple <br />NOTES: <br />Seed mix to be o 50/50 ratio of the above native and wildflower MiXeS. <br />Seeding rate - 15 lbs. per acre <br />PG <br />5 <br />16 <br />EPP <br />2 <br />EPP <br />PLANT LIST <br />Symbol A 2z1 <br />DECIDUOUS TREES <br />E0 2 2.5" cal. <br />EM 4 <br />EVERGREEN TREES <br />EPP 16 Existing <br />U.J3 4' B.SB <br />Botanical Name <br />Quercus macrocarpa <br />Pinus ponderosa, Existing <br />Juniperus scopulorum <br />ORNAMENTAL TREES <br />CP 1 4' NB Pyrus <br />DECIDUOUS SHRUBS <br />513 1 5 gal. <br />Amelanchier stolonigera <br />EVERGREEN SHRUBS <br />JU 11 5 gal. Juniperus horizontalis 'Prince PT <br />MR 15 2-1/4" Mahonia repens <br />PERENNIALS, GROUND COVERS, AND ORNAMENTAL GRASSES <br />PG 21 5 gal. Erianthus ravennae <br />51_ 15 1 gal. Hemerocallis 'Stella D'Oro' <br />5R 41 5 gal. Rosa x 'White Meidiland' <br />NOTES <br />Common Name <br />English Oak <br />Existing Maple tree <br />Existing Ponderosa Pine <br />Upright Juniper <br />Chanticleer Pear <br />Running Serviceberry <br />Prince of Hales Juniper <br />Creeping Oregon Grape Holly <br />Harday Pampas Grass <br />Stella D'Oro' Daylily <br />Double White Shrub Rose <br />I. The area to be revegetated with a seed mix shall o be a combination of annual and perennial <br />wildflowers as well as native grasses which include both cool and warm Season species. <br />2. All trees shall be staked for a minimum of one year. <br />3. All hardscaped areas shall include sleeving to provide irrigation pipes to all newly landscaped <br />areas. <br />4. All seeded areas will be provided temporary irrigation to establish the turf. <br />5. All mulch beds to be shredded bark. <br />6. All sod to be a fescue mix. <br />5R <br />II <br />E0/ <br />3 <br />SL <br />1 <br />SL <br />EXISTING BLDG <br />Nz- ASPHALT it <br />SleN (SEE DETAIL 5HT A2 <br />P6 <br />6 <br />SR <br />JIJ <br />3 <br />NEN ADDITION <br />O <br />EPP <br />3 <br />---------- <br />LANDSCAPE PLAN <br />N SCALE I" = 201-0" <br />\z- SOD -7‘ <br />----- <br />NATIVE <br />RELOCATE OR <br />e- <br />GRASSES <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />• <br />• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />•• <br />NATIVE <br />GRASSES <br />‘‘- ASPHALT <br />REPLACE (3) EPP <br />L <br />a <br />SR (EXISTING) <br />10 <br />POLE <br />SQUARE STRAIGHT <br />STEEL POLE <br />25' HIGH <br />DARK BRONZE FINISH <br />HAND HOLE <br />COMPRESSION <br />CONNECTION <br />r FIXTURE "D" <br />AT +23' ABOVE GRADE <br />I <br />SINGLE -HEAD LUMINAIRE <br />FINISH TO MATCH POLE <br />ANCHOR BOLTS. PROVIDED <br />BY E.C., INSTALLED BY G.C. <br />GRADE <br />a 1/2" PVC ----71 <br />1 /2 lx8IONG <br />COPPER CLAD <br />GROUND ROD <br />4#4 REBARS WITH <br />#4 REBAR TIES AT <br />12" O.C. <br />24" DIA. CONCRETE <br />BASE BY GENERAL <br />CONTRACTOR <br />V OU NTED AREA LIGHT INSTALLATION DETAIL <br />SITE PHOTOMETRIC SUMMARY <br />AVERAGE = 1.3 FT. CANDLE <br />MAXIMUM = 12.5 FT. CANDLE <br />MINIMUM = 0.0 FT. CANDLE <br />PARKING AREAS: <br />AVERAGE =2 FT. CANDLE <br />MAXIMUM = 11 FT. CANDLE <br />MINIMUM = 0.2 FT. CANDLE <br />BUILDING ENTRANCES <br />AVERAGE =6 FT. CANDLE <br />MAXIMUM = 12.5 FT. CANDLE <br />MINIMUM = 1.3 FT. CANDLE <br />NO SCALE <br />r <br />ITEM MANUFACTURER <br />+0.0 +0.0 +0.0 +0.1 +0.1 0.1 <br />AMS111.1011 <br />-±0-7- 0.2 0.4 <br />- <br />+ <br />, so <br />." <br />+0_0 !o.o- O1U2---' -ITO- <br />+0.1 1 +0.3 +0.7 +1.2 <br />A _ LITHONIA <br />B INDESSA LIGHTING <br />C LITHONIA <br />D LITHONIA <br />+0.0 +0.0 <br />FIXTURE A <br />FIXTURE C <br />LIGHTING FIXTURE SCHEDULE <br />CAT. NO, <br />WST 100M MD <br />425-2CFQ13-WH7 <br />KBD850MR5LV208 <br />KSF3400MR3SPO4 <br />HSS <br />+0.1 +0.1 *0.1 +0.1 <br />LAMPS WATTS <br />150 <br />30 <br />70 <br />450 <br />(1) 100W MH <br />(2) 13W CFL <br />(1) 50W MH <br />(1) 400W MH <br />DESCRIPTION <br />FIXTURE B <br />FIXTURE D <br />CUT-OFF TYPE TRAPEZOIDAL WALL LIGHT INSTALLED 12' ABOVE GROUND <br />SULINDRICAL SHIELDED WALL LIGHT AT EXIT DOOR <br />ROUND BOLLARD LIGHT WITH LOUVERS <br />SHOE BOX TYPE SITE POLE LIGHT ON 25 FT. POLE, HOUSESIDE SHIELD <br />+0.1 9.1 +0.1 +0.1 49.1 +0.1 +0.1 +0.1 +0.0 +0.0 <br />+0.2 +0.2 ' +0.2 +0.2 +0.2 +0.3 +0.3 <br />- - <br />L <br />+0.7 <br />1.0 1.3 28 +$7 <br />16 SPACES D <br />+2.0 +4.6 +5.2 +1.3t.2 3.3 +6.3 <br />1411.5 1.5 1.8 +1.3 <br />+.4.5 +5.1 +3.9 +2.2 <br />0.0 0.1 0.4 0.8 1.7 2.9 '1 4.2 3.1 +1.8 1.8 1.5 <br />+0.3 +0.6 +1.2 +2.0 +1.7 +1.0 +0.7 +1.0 +0.9 <br />+0.0 19.1 +0.1 <br />+0.0 +0.1 +0.11 +0.2 <br />+0.0 +0.1 +0.2 <br />+0.0 +0.1 +6 1 +0.2 <br />1 <br />+0 1 r0.1 <br />0.1 /0.2 <br />I+ <br />1 <br />+o.iI 0.2 <br />0.1 0.11 +0.2 +0.4 <br />+ <br />+0.1 +0L1 +0.2 +0.3 <br />+0.1 +CIA +0.1 +0.2 <br />O0 +11 +0.1 <br />BUILDING <br />+0.0 0UU1 <br />0.0 +0.1 <br />1 <br />+0.0 .9 19.1 <br />+0.0 +0.1 40.1 <br />1 <br />+0.0 -F0.1 <br />+0.0 0.0 +0.0 <br />+0.0 49.0 <br />0.0 13. 0.0 0.0 <br />+0.0 40.0 +0.0 lu.0 <br />+0.1 <br />+0.2 <br />+0.5 <br />+0.4 +0.7 ÷0.5 +0.3 +Q.4 +0.5 +0.7 +0.6 <br />, Val <br />▪ ^ <br />0.• 1 <br />+OA 04 <br />WM <br />+0.0 +0.0 +0.0 +0.0 +0.0 +0.0 <br />+0.0 +0.0 0.0 +0.0 +0.0 +0.0 +0.0+0.0 +0.0- -+0.0 <br />-- - - - <br />•0. 0.1 <br />--- <br />00 00 0.0 0.0 0.0 <br />EXIST' <br />0.1 +0.0 +0.0 0.0ELEtOZRA-00 +0.0 +0.0 +0.0 <br />EXIST'& <br />TRAWORMER <br />0.1 0.0 +0.0 <br />+5.8 +4.0 +2.4 +1.2 +0.6 +0.3 0.2 +0. +4.0 +3.0 <br />1.5 2.1 3.0 2.5 1.4 0.7 0.4 1.13 -1E9.4 6.4 <br />+0.6 +0.9 +3.6 +5.7 +3.5 +0.9 +1.1 +2. +2. <br />- -1 +8 FT <br />+12 FT + A +1213 +51 <br />+0.3_ +0.7 4.6 A op (>11.5 4.8 <br />1 1 1 <br />I I 1 / +12 fT <br />L _J 6. <br />+0.3 +0.3 +041.::,SPI.F5 +2.2 2.2 +0.g` +0.2 <br />H.C. H.C. <br />0.2 +0.2 0.2 0.6 4.9 A9125 i419 +0.6 0.1 <br />+12 FT <br />0.2 <br />0.4 <br />BOLLARD <br />LT <br />0.6 1.3 0.6 <br />1.2 3.2 3.1 <br />54446Re47:1 <br />EXIFFING--/ <br />WALL÷PAL3K.. <br />1.1 2.9 2.4 <br />0.6 1.1 0.5 <br />B+AARD+P§ <br />LT <br />0.1 0.1 0.1 0.0 <br />0.1 <br />LOT 11 <br />EXISTING BLDG <br />aprox 4,142 s.f. <br />NEW ADDITION <br />aprox 6,000 s.. <br />• / <br />6+8 FTI <br />(F4AC 141 <br />VELOPE <br />G71- 110- -00- -VG -0F 0TO 0Y tJ.1- 02- i7" - 86-±27k <br />BOLLARD <br />LIGHTS <br />0.0 0.0 0.0 0-.1) -0.0 .0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.7 0.8 0.5 <br />0.0 0.0 9.0 1-0.0 0.0 0.0 0.0 0.0 0.0 0.0 9.0 <br />I 015 <br />0.0 <br />L.0 <br />0.0 <br />0.0 10.0 +00 0.1 0.1 0.1 0.2 0.2 <br />U <br />U . V <br />+12 FT <br />5.2 4▪ 1 L!1273 -L-'33 <br />r)." <br />HIGH <br />2.0 1.8 2.4 47 95 <br />2.3 1.8 3.1 35 1-2.8 <br />2.1) <br />+2. <br />+2.6 5.0 3▪ 4 1.3 <br />54 6.1 2.4 40.8 <br />8.8 6.0 <br />trl <br />+45 +59 <br />H <br />111 <br />EXIST' <br />LOADING DOCK <br />1A-0(1-11 +-0-1 <br />HIGH <br />6.5 1.1 0, 2 <br />H4-0.4 ().2 <br />1.7 0.7 0.4 +10.2 0 <br />37 +1.6 1.0 0.6 03 +0.2 <br />0.7 04 O. 2 <br />0.7 04 0. 3 rE; <br />45 5.9 +4,0AI,ST+I1 7 1.1 <br />N'u <br />POLE MOUNTED <br />+6L JIG HT+2FoXT E0 <br />4.1 9▪ 5 <br />5▪ 5 6.4 3.0 1.7 <br />EXIST' <br />EXIT <br />1.4 10 0.6 0.8 <br />+9174, 3.2 5.6 4▪ 3 2.9 3.0 2.3 1.3 1.1 1.3 <br />1.7 1.8 3.3 +4.1 3.8 4.2 4.8 4.0 2.5 2.2 <br />4-u.v +1.2 2.1 2.6 2.7 2.9 4.8 6.2 95 +5.0 <br />0.i3 +04 0.7 1.1 1.4 1.8 1.9 2.5 37 +73 <br />0.2 0.3 0.5 +.7 1.0 1.3 1.8 3.1 37 3.8 <br />+0.1 01 03 to.4z 0.5 +a7 +1-.2 1.8 2.3 <br />0.0 0.0 0.0 0.0 0.0 0.0 9.0 +o.o 0.0 o.o 0.0 0.0 0.0 0.0 0.0 0.0 'o.o 0.0 0.0 0.0 0.0 ----OE0 0.1 <br />- <br />SITE PHOTOMETRIC PLAN <br />N SCALE 1" = 20'-0" <br />+ + <br />0.1 "O.2 0.3 <br />I I <br />0.4 0.6 -- 1-.0 1.5 1.3 0.9 <br />RG ENGINEERING CONSULTANTS <br />ELECTRICAL CONSULTANTS <br />720 S. COLORADO BLVD. SUITE 740-N <br />DENVER, CO 80246 <br />(303) 355-5534 (tel) <br />(303) 355-5509 (fax) <br />NOTICE: DUTY OF COOPERATION <br />Release of these plans contemplates <br />further cooperation among the owner, his <br />contractor and the architect. Design and <br />construction are complex. Although the <br />architect and his consultants have <br />performed their services with due care and <br />diligence, they cannot guarantee perfection. <br />Communication is imperfect, and every <br />contingency cannot be anticipated. Any <br />ambiguity or discrepancy discovered by the <br />use of these plans shall be reported <br />immediately to the architect. Failure to <br />notify the architect compounds <br />misunderstanding and increases <br />construction costs. A failure to cooperate <br />by a simple notice to the architect shall <br />relieve the architect from responsibility for <br />all consequences. Changes made from the <br />plans without consent of the architect are <br />unauthorized, and shall relieve the architect <br />of responsibility for all consequences <br />arriving out of such changes. <br />0 <br />808 S. Public Rd., Suite 100 I Lafayette, (080226-2194 <br />Phone: 303.604.2900 I Fax: 303.604.2905 <br />JOB NO: 1 407 <br />DRAWN: br <br />CHECKED: <br />DATE: 04-17-07 <br />REVISED: 05-31-07 <br />06-20-07 <br />• <br />