Laserfiche WebLink
DO NOT CUT SINGLE LEADER, <br />PRUNE DAMAGED OR DEAD <br />WOOD, AND CO—DOMINANT <br />LEADERS AT LANDSCAPE <br />ARCHITECTS DIRECTION ONLY. <br />14 GAUGE GALV. WIRE <br />WITH <br />PVC <br />ON NLNGGTHO <br />EACH WIRE <br />SPECIFIED TREE STRAP <br />— ALIGN NW/SE <br />SPECIFIED POSTS <br />— ALIGN NW/SE <br />WRAP ENTIRE SURFACE OF <br />TRUNK UP TO SECOND BRANCH <br />WITH SPECIFIED WRAPPING <br />SECURED AT TOP AND BOTTOM <br />& AT TWO FOOT INTERVALS. <br />RE: SPECS FOR TIMING <br />RE: FINAL TOP ROOTBALL GRADE <br />PLANT TREE 3" ABOVE <br />FINAL TOP ROOTBALL GRADE <br />MULCHAF�ING, SPECIFIED <br />INEDTURFFOAREAS. <br />;,•,.:,, GRADE TO SLOPE AWAY FROM <br />ROOTBALL <br />SPECIFIED BACKFILL/FERTILIZER <br />AS PER SPECIFICATIONS <br />(IONS <br />REMOVE ALL TWINE ANQ WIRE <br />PULL BURLAP BACK 2/3 MINIMUM <br />UNDISTURBED OR COMPACTED <br />SUBGRADE <br />SETTLING OF ROOTBALL SHALL <br />BE CAUSE FOR REJECTION <br />DECIDUOUS TREE PLANTING <br />N.T.S. <br />PRUNE ALL DAMAGED OR DEAD <br />WOOD IMMEDIATELY PRIOR TO <br />PLANTING. <br />SET SHRUB 2" HIGHER THAN THE <br />GRADE AT WHICH IT GREW. <br />APPLY SPECIFIED MULCH <br />4" DEEP: SEE SPECIFICATIONS <br />FOR FERTILIZER APPLICATION IN <br />BACKFILL MIXTURE. <br />DIG PLANT PIT TWICE AS WIDE <br />AS THE CONTAINER OR MORE. <br />REMOVE CONTAINER. <br />LOOSEN SIDES OF PLANT PIT <br />AND ROOTBALL. <br />FILL PLANT PIT WITH SPECIFIED <br />SOIL MIX INCLUDING SPECIFIED <br />FERTILIZER. <br />CONCRETE CURB OR SIDEWALK. <br />NOTES: <br />1. ANY BROKEN OR CRUMBLING ROOTBALL WILL BE REJECTED. <br />REMOVING THE CONTAINERS WILL NOT BE AN EXCUSE FOR DAMAGED <br />ROOTBALLS. <br />2. HOLD GRADE 1" BELOW EDGE OF WALK OR CURB. THIS DETAIL <br />SHALL ALSO APPLY TO PERENNIAL FLOWERS IN CONTAINER. <br />3. ALL JUNIPER PLANTS SHOULD BE PLANTED SO TOP OF ROOT <br />MASS OCCURS AT FINISH GRADE OF MULCH LAYER. <br />SHRUB PLANTING DETAIL <br />N.T.S. <br />KEY BANK at CENTENNIAL VALLEY <br />CENTENNIAL VALLEY BUSINESS PARK <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO <br />ADMINISTRATIVE PUD AMENDMENT <br />12" <br />NOTES: <br />DO NOT CUT LEADER <br />SPECIFIED TRUNK ATTACHMENT <br />DOUBLE STRAND SPECIFIED WIRE <br />PROVIDE 3 GUY SYSTEMS EQUI— <br />DISTANT AROUND TREE. <br />PLACE 1/2" WHITE PVC, <br />24" LENGTH ON ALL GUYING <br />SPECIFIED WO D MULCH (4" DEPTH <br />IN ALL AREAS) <br />SPECIFIED STAKES DRIVEN <br />FLUSH WITH GRADE <br />PLANT TOP OF ROOT BALL AT <br />FINAL GRADE W/ WATERING BASIN <br />IN NATIVE GRASS AREAS. PLANT <br />ROOT BALL 3" HIGHER THAN FINAL <br />GRADE IN IRRIGATED LAWN AREAS. <br />SPECIFIED BACKFILL/FERTILIZER <br />SET ROOT BALL ON EXISTING <br />UNDISTURBED SUB—SOIL. <br />1. INSTALL SPECIFIED MULCH TO DRIPLINE OF TREE WHERE PLANTED <br />IN GRASS AREAS. <br />2. DO NOT PROVIDE WATER BASIN IN IRRIGATED LAWN AREAS. <br />EVERGREEN TREE PLANTING <br />SHRUB BED W/ SPECIFIED <br />MULCH DEPTH <br />LAWN AS SPECIFIED <br />1/2" <br />SPECIFIED STEEL EDGING <br />METAL STAKES AS SPECIFIED <br />NOTE: <br />1. SET ALL EDGING 1/2" ABOVE <br />FINISH GRADE AND MULCH AS <br />SHOWN. EDGING SHALL ABUT ALL <br />CONCRETE CURBS AND WALKS <br />PERPENDICULAR AND FLUSH W/ <br />GRADES OF CONCRETE. ALL <br />JOINTS TO BE SECURELY STAKED. <br />STEEL EDGER DETAIL <br />N.T.S. <br />N.T.S. <br />LANDSCAPE NOTES <br />1. ALL SOD AREAS AND SHRUB BEDS SHALL BE ROTOTILLED WITH ORGANIC <br />COMPOST AT THE RATE OF 4 CUBIC YARDS PER 1,000 SQUARE FEET. <br />THIS PREPARTATION SHALL BE THOROUGHLY INCORPORATED INTO THE <br />TOP 6" OF SOIL. <br />2. ALL LANDSCAPE AREAS SHALL BE WATERED BY AN UNDERGROUND <br />AUTOMATIC IRRIGATION SYSTEM. ALL IRRIGATED TURF AREAS LESS THAN <br />25' WIDTH SHALL HAVE A POP—UP SPRAY SYSTEM AND ALL IRRIGATED <br />TURF AREAS GREATER THAN 25' WIDTH SHALL HAVE A ROTARY POP—UP <br />SYSTEM PROVIDING HEAD TO HEAD COVERAGE. ALL TURF AREAS LESS <br />THAN 10' WIDTH BETWEEN IMPERVIOUS SURFACES SHALL REQUIRE A <br />SUBSURFACE (NO POP—UP OR SPRAY HEADS) SYSTEM. ALL SHRUB <br />BEDS SHALL HAVE FULL COVERAGE WITH A DRIP SYSTEM. ALL TREES <br />IN NON—IRRIGATED NATIVE SEED AREAS SHALL HAVE FULL COVERAGE WITH <br />A DRIP SYSTEM. <br />3. ALL TURF AND SHRUB BEDS SHALL BE ZONED SEPARATELY. ALL <br />MAINLINE AND LATERALS SHALL BE PVC SOLVENT WELD PIPE SIZED <br />TO MAINTAIN VELOCITY BELOW 5 F.P.S. ALL HEADS SHALL BE <br />DESIGNED AND ADJUSTED TO MINIMIZE OVERSPRAY ONTO WALKWAYS <br />AND ROADWAYS. <br />4. SIDEWALKS AND PARKING SHALL BE CONSTRUCTED OF CONCRETE. <br />5. ALL SHRUB BEDS SHALL BE CONTAINED WITH STEEL EDGER. STEEL <br />EDGER NOT REQUIRED AT CURB, WALK, OR BUILDING. <br />6. ALL PERENNIAL/ORNAMENTAL GRASS BEDS SHALL HAVE 4" DEPTH <br />SPECIFIED MEDIUM BARK WOOD MULCH. DO NOT PLACE FILTER FABRIC <br />UNDER WOOD MULCH. <br />7. ALL SHRUB BEDS SHALL HAVE 4" DEPTH SPECIFIED 1-1/2" CRUSHED <br />GRANITE ROCK MULCH OVER SPECIFIED FILTER FABRIC. <br />8. ALL NON—IRRIGATED ZONES ADJACENT TO THE BUILDING SHALL HAVE <br />4" DEPTH SPECIFIED 1-1/2" CRUSHED GRANITE ROCK MULCH OVER <br />SPECIFIED FILTER FABRIC. <br />ALL IRRIGATED SOD SHALL HAVE AT LEAST A MIX OF 4 VARIETIES OF <br />DROUGHT TOLERANT BLUEGRASS SPECIES. <br />ALL UTILITY EASEMENTS SHALL REMAIN UNOBSTRUCTED AND FULLY <br />ACCESSIBLE ALONG THEIR LENGTH. <br />ALL LANDSCAPING WITHIN THE PUBLIC RIGHT OF WAY SHALL BE <br />MAINTAINED BY THE DEVELOPER. <br />12. NEW LOCATION OF RELOCATED TREES IS TO BE DETERMINED BY OWNER. <br />13. A WATER MAIN LINE ALONG MCCASLIN BLVD. PROHIBITS THE PLANTING <br />OF TREES BETWEEN THE SIDEWALK AND CURB. <br />site design <br />landscape architecture <br />site planning <br />852 broadway, suite 250 <br />denver, Colorado 80203 <br />303.512.0549 fax 303.812.1224 <br />FOR AND ON BEHALF OF <br />JANSEN STRAWN CONSULTING ENGINEERS, INC. <br />BENCHMARK: <br />Description of Revisions <br />0 <br />z <br />N <br />U <br />m <br />m <br />a, <br />U) <br />a, <br />CALL UTILITY NOTIFICATION <br />CENTER OF COLORADO <br />811 <br />CALL 2 BUSINESS DAYS IN ADVANCE <br />BEFORE YOU DIG, GRADE OR <br />EXCAVATE FOR THE MARKING OF <br />UNDERGROUND MEMBER UTILITIES. <br />Hor.: N/A <br />Scale: Vert.: N/A <br />Date: MAY 16, 2008 <br />Job No.: 08.114 <br />S JP -5 <br />1;z: <br />