My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Home Depot Tool Rental Center PUD Mylar
PORTAL
>
RECORDED PLATS (Mylars) and CITY MAPS
>
PUD (Planned Unit Developments)
>
H
>
Home Depot Tool Rental Center PUD Mylar
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/5/2018 11:11:36 AM
Creation date
5/1/2017 1:10:07 PM
Metadata
Fields
Template:
CITYWIDE
Also Known As (aka)
The Home Depot
Doc Type
Mylar
Ord/Res - Year
2004
Ord/Res - Number
27
Subdivision Name
Louisville Home Depot
Parcel Identification Number
157713014001
Cross-Reference
PC Res 2004-11
1200 Dillon Rd
Record Series Code
40.180
Record Series Name
Maps Drawings Plats Plans
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REMOVE PARKING SPACES TO ALLOW FOR <br />NEW LANDSCAPED ISLANDS (TYP) <br />(SHADED AREA = ±844 SFy <br />• <br />1 <br />i <br />1 <br />1 <br />1 <br />) <br />18 <br />10 <br />( ) <br />FIRE LANE <br />—► I <br />COLONY SQUARE SUBDIVISION' <br />PROPERTY LINE <br />4'-0" SCREENING FENCE TO BE REPAIRED OR REPLACED AT DAMAGED AREA <br />r <br />( <br />14 <br />15 <br />( <br />16 <br />) <br />17 <br />( <br />18 <br />16 <br />) <br />18 <br />16 <br />20 <br />-46 <br />(Th <br />1 <br />( <br />( <br />18 <br />( <br />REMOVE PARKINS SPACES TO ALLOW FOR <br />NEW LANDSCAPED ISLANDS (TYP) <br />rSHAPFP APFA = .+_'.620 ASF) <br />SPE:IAL <br />EVENT <br />(18) <br />18 <br />. .— LE LE _ I_ KM 1 -I— MI T <br />( 16 16 <br />) ( ) <br />_ FIRE LANE <br />EP—LA—NT—S I rFL�� <br />z <br />NEW STRIPING OF THE FIRE LANE IN FRONT OF THE <br />TWO (2) TRG EXIT DOOR, EXTENDING INTO THE <br />PARKING LOT (ALERTING PEDESTRIANS AND <br />VEHICLE TRAFFIC THAT CUSTOMERS MAY BE <br />TRAVELING OUT OF THE TRG AND INTO THE <br />TRAFFIC LANES) <br />FIRE LANE <br />S <br />4 <br />EXIST. WOOD STORAGE RACK SHALL BE <br />ENCLOSED FROM PUBLIC VIEW WITH METAL SHED <br />AND FABRIC DOORS <br />(SEE DWG A301 FOR ELEVATION) <br />NORTH <br />SITE PLAN <br />SCALE r • 40'-O" <br />.1M•1•11 .moNNO <br />GRAPHIC SCALE <br />MI OM <br />MI MI <br />0 40 <br />• EXISTING • <br />THE HOME DEPOT <br />STORE NUMBER 1506 <br />.U: <br />AREA = 106,945 SF <br />80 120 FT. <br />0 <br />EXISTING FI <br />RANSFORME <br />PROPERTY LINE <br />PROPOSED <br />TOOL RENTAL CENTER <br />AREA: = 1,900 SQ.FT. <br />PROPOSED <br />OUTDOOR LARGE EQUIP. STOR. <br />AREA: = 600 SQ.FT. <br />EXISTING SITE LIGHTING <br />TYP I CAL <br />,r <br />GAS <br />AREA <br />• <br />E <br />ISTING <br />18 <br />17 <br />TREES <br />r <br />UTDOOR <br />1N- -C ENT R <br />= 24,163 SF <br />— J <br />00111110 <br />FIRE LANE <br />16 <br />16 <br />1 <br />1 <br />0 <br />-6J <br />----HATCHED AREA <br />• SEASONAL <br />SSTORAGEONY <br />MAR. 01 TO SEP. 01 <br />(48) <br />18 <br />( <br />38 <br />ELPIED SPACES(LOW FOR <br />NEW LANDSCAPED ADTYR <br />(SHADED AREA = ±2,c1I6 SF) <br />— — — — PROPERTY LINE <br />SUMMARY <br />CIVIC ADDRESS: <br />1200 DILLON ROAD <br />LOUISVILLE, COLORADO 80027 <br />LEGAL DESCRIPTION: <br />LOT 1, LOUISVILLE HOME DEPOT, ACCORDING TO THE PLAT <br />RECORDED JANUARY 2, 1996 AT RECEPTION NO. 1573746, <br />COUNTY OF BOULDER, <br />STATE OF COLORADO. <br />ZONING: <br />P,U.D. <br />PARCEL SITE AREA: <br />THE HOME DEPOT (LOT 1) <br />BUILDING AREA: <br />±502,231 SF (±11.529 <br />HOME DEPOT (EXISTING) <br />PROPOSED TOOL RENTAL CENTER ADDITION <br />BLDG TOTAL : <br />OUTDOOR GARDEN CENTER (EXISTING) <br />PROPOSED OUTDOOR LARGE EQUIP. STOR. <br />TOTAL GROSS FLOOR AREA : <br />SITE COVERAGE: <br />AC) <br />104,800 SF <br />1,900 SF <br />106,700 SF <br />14,163 SF <br />600 SF <br />121,463 SF <br />HOME DEPOT (EXISTING + <br />PROPOSED TRC) 24.2% (10,535 SF/AC) <br />PARKING SUMMARY: <br />PARKING REQUIRED ® 4.5 SPACE/1000 <br />EXISTING HOME DEPOT STORE <br />PROPOSED TRC ADDITION <br />EXISTING GARDEN CENTER <br />PROPOSED OUTDOOR EQUIP. STOR. <br />TOTAL REQUIRED: <br />EXISTING PARKING SPACES <br />SPACES REMOVED TO ALLOW <br />FOR CONSTRUCTION OF <br />LANDSCAPED ISLANDS <br />TOTAL PARKING PROVIDED: <br />SF <br />= 472 SPACES <br />= 9 SPACES <br />= 64 SPACES <br />3 SPACE <br />= 548 SPACES <br />( ) <br />= 512 SPACES <br />= 33 SPACES <br />= 479 SPACES <br />PER HOME DEPOT OPERATIONS: <br />NUMBER OF PARKING ACTUALLY <br />USED ON THE BUSIEST DAY (75% X 512) = 384 SPACES <br />SEASONAL PARKING SUMMARY: <br />TOTAL PARKING PROVIDED (OFF SEASON): = 479 SPACES <br />SPECIAL EVENT: <br />YEAR ROUND EVENT: I.E. WEEKEND THE HOME DEPOT <br />NASCAR DISPLAY/FIRE TRUCK FOR SAFETY MONTH <br />(NO FENCING REQUIRED) (-) = 18 SPACES <br />TOTAL PROVIDED: = 461 SPACES <br />SEASONAL STORAGE: <br />MARCH 01 TO SEPTEMBER 01: STORAGE FOR <br />PALLETIZED PRODUCT <br />8'-0" HIGH CHAIN-LINK FENCE <br />TOTAL PROVIDED: <br />(-) = <br />UNIVERSITY OF COLORADO: <br />BI -ANNUALLY: SOLAR VEHICLE PROJECT <br />(NO FENCING REQUIRED) (-) = <br />TOTAL PROVIDED: _ <br />SIGNAGE REQUIREMENT: <br />EXISTING SIGNAGE <br />NEW SIGNAGE (SEE ELEVATION) <br />TOTAL ALLOWABLE <br />SEASONAL <br />48 SPACES <br />431 SPACES <br />16 SPACES <br />463 SPACES <br />= 398 SF <br />(+) = 50 SF <br />= 448 SF <br />OPEN SPACE REQUIREMENT: <br />EXISTING 25% + 1.1% (±5,380 SF : PROPOSED) = 26.1% <br />LANDSCAPE LEGEND: <br />SHADED AREAS DENOTES NEW LANDSCAPED AREA <br />(SEE LANDSCAPE DWGS.) <br />This drawing is an instrument of service and remains the <br />property of Omicron Consulting Group, Prime Consultant and <br />licensed Professional of Record ("PR"). All information shown <br />on this drawing is copyright material and is for use on the <br />named project only. Information contained herein may not be <br />used or reproduced in anyway without written permission. All <br />approved reproductions of this drawing shall bear the <br />designated firm names. <br />Drawings shall not be scaled. The Contractor shall verify and <br />be responsible for all dimensions. datum and elevations <br />pertinent to executing the work. Discrepancies and variations <br />shall be reported to the PR before work is performed. In all <br />cases the latest version of the contract documents shall be <br />used on site. The contractor shall ensure all previous <br />versions are marked "Superseded" with reference to a <br />revision number. All work shall conform to the current local <br />Building Code, jurisdictional codes and local ordinances. <br />DRAWING REVISIONS / ISSUES <br />0 <br />0 <br />10C <br />0 <br />J <br />0 <br />V <br />0 <br />LO <br />T <br />MAY. _ISSUED FOR FINAL PUD <br />10/04 AMENDMENT <br />DATE - REMARKS <br />total building solutions <br />NO. <br />Suite 201, 2630 — 116th Avenue N.E., Bellevue, WA. 98004 <br />Tel: 425.822.2027 • Fax: 425.822.2287 <br />www.omicronconsulting.com <br />CONSULTANT <br />ERIK KLEPP. ARCHITECT <br />PROJECT <br />HOME IMPROVEMENT WAREHOUSE <br />SE <br />DRAWING TITLE <br />SITE PLAN <br />TECH. <br />CHK'D <br />EK <br />DESIGN <br />CHK'D <br />AS SHOWN <br />ML <br />SCALE <br />HOME DEPOT <br />TOOL RENTAL <br />CENTER <br />STORE # 1506 <br />1200 DILLON ROAD <br />LOUISVILLE, COLORADO <br />80027 <br />DATE <br />JOB No. <br />MAY 10/03 <br />9003049 <br />DRAWING No. <br />Al 01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.