Laserfiche WebLink
Steel Ranch South <br />CO <br />CV <br />O <br />10 <br />T:\Jobs\RMCS\Steel Ranch South\Plan Sets\FDP PA4A-B\FDP-PA4B.dwg, Layoutl, 6/19/2012 5:07:58 PM, arinv <br />STEEL RANCH SOUTH <br />FINAL DEVELOPMENT PLAN <br />SOUTHEAST QUARTER OF SECTION 5, TOWNSHIP 1 SOUTH, RANGE 69 WEST OF THE 6TH <br />PRINCIPAL MERIDIAN, BOULDER COUNTY, CITY OF LOUISVILLE, COLORADO <br />6' DRY U.E <br />[III 1iun inn <br />( IN FEET ) <br />1 inch = 60 ft. <br />PLANNING AREA 4B <br />SCALE: 1" = 60' <br />• <br />Yew .cq., <br />AU.\UUUA�?Ql�` <br />PLANNING AREA 48 NOTES AND STANDARDS <br />1. Multi -Family Planning Area 4B shall accommodate up to 228 dwelling units, associated parking, open areas and <br />amenities. Unit count may vary depending on final housing product design, but in no event shall the total number of <br />dwelling units exceed 228. Density of 228 dwelling units is achievable predominately with surface parking and (podium <br />or tuck -under) parking as indicated on Site Plan. <br />2. Parking Ratio and Parking Types: Multi -Family Planning Area 4B is intended to maintain a minimum overall parking <br />ratio for residents, guests, and employees, of 1.70/DU, not including tandem parking spaces, with the overall ratio up to <br />2.0 including all types of parking within PA -4B. This area includes 4 primary types of parking in addition to limited <br />on -street parking: a.) Surface Parking Lots; b.) Tuck -Under individual parking garages, (enclosed or unenclosed) <br />provides 2 parking spaces in tandem, with one space in the apron of the garage. If tuck -under garages are enclosed, <br />they can serve as secure storage areas for the residents; c.) Individual Garages within free-standing Garage Buildings, <br />remote from the dwelling units; d) Under Building, or podium parking garage for multiple vehicles, integrated into the <br />building architecture, may be below grade. Parking for persons with disabilities shall be provided as required by code at <br />the time of building permit, and locations, quantities etc. as generally shown on this PUD are subject to change. <br />3. Site Circulation Concept: Multi -family Planning Area 4B is serviced by two major access points: from South Boulder <br />Road and from Hecla Drive. The main circulation through Steel Ranch South is Steel Street on the west side of the <br />development, which runs north past the multi -family housing in Planning Area 4B to the single family homes attached in <br />Planning Area 4A, with primary east -west access, known as Steel Ranch South Boulevard into the multi family site just <br />south of the clubhouse. This connects to a north -south primary drive through the heart of the multi -family site with <br />parking on each side. A parking area on the south of the central green space also serves the leasing office and <br />clubhouse for neighborhood functions. <br />4. Architectural Design Concept: Multi -family Planning Area 4B is envisioned as a higher density housing community to <br />create a diversity of housing types within the City of Louisville. To provide a unique sense of place and neighborhood feel <br />for the residents, it is intended that a variety of materials and architectural treatments are utilized for different buildings <br />and zones within this part of the development. Buildings A -D is envisioned as a podium design with under building <br />parking as well as surface parking. Buildings E -G are located sharing the green space and would have a variety of tuck <br />under parking as well as surface parking. The community clubhouse would be located in the center of the community <br />and the architecture would be similar in style to that of the apartment buildings. <br />5. The building configuration, design, parking layout, etc. as depicted herein is subject to further market analysis aid <br />design study, and as such may vary from the Final PUD to the Building Permit submittal. Such variations which are <br />within 15% of the designs indicated herein shall be acceptable without a PUD amendment. Maximum densities and Bulk <br />and Dimensional Standards shall be maintained. <br />6. Sustainability Goals: Sustainability Goals: Multi -family Planning Area 48 is proposed to incorporate several <br />sustainability features into the buildings and site design that will conserve energy, reduce water consumption, and greater <br />use environmentally preferred products by following LEED guidelines for the construction of new multi -family residents. <br />7. Multi -family dwelling units within 100 feet of Railroad ROW will incorporate noise -mitigation via enhanced wall <br />construction and window specification, including a minimum exterior wall Sound Transmission Coefficient of 55 facing the <br />Railroad ROW, with tight fitting triple pane windows, and solid core doors. <br />8. Site specific Bulk and Dimension Standards on this sheet for Planning Area 4B shall govern development of this <br />Planning Area. <br />PLANNING AREA 4B <br />LAND USE: <br />GROSS LAND AREA: <br />MAX. DWELLING UNITS <br />(BASED UPON ACTUAL TRACT SIZE): <br />MAX. GROSS DENSITY <br />MAX. LOT COVERAGE <br />RESIDENTIAL AREA:1 <br />MAXIMUM BUILDING HEIGHT: <br />1 NOT INCLUDING HECLA DRIVE ROW, STEEL STREET ROW <br />DEVELOPMENT SUMMARY <br />PCZD-R <br />±9.43 Ac. <br />TRENT •ELEVATION .(STR.EETSIDE .VI <br />228 DU <br />30 DU /Ac <br />85% <br />±7.79 Ac (82.6%) <br />55' MULTIFAMILY <br />L <br />BLDG <br />A <br />B <br />C <br />D <br />E <br />F <br />G <br />CH <br />Totals <br />Description 1 Total DU I 1 BF <br />Podium Style 3 33 15 <br />Podium Style 33 15 <br />Podium Style a 33 <br />Podium Style 33 <br />Tuck Under 33 19 <br />Tuck Under 30 16 <br />Tuck Under 33 19 <br />aubhouse 0 0 <br />228 114 <br />UNITCOUNTAND PARKING SUM M ARY <br />2 BF <br />15 <br />15: <br />15 15 <br />15 15 3 <br />14: <br />14 <br />14 <br />Parking Provided <br />3BR Sit -face 1 Garage 1 Tandem I Pot. Carport <br />3 12 36 0 7 <br />3 38 <br />3 21 <br />25 <br />0 23 <br />0 2 <br />0 11 <br />0: 0 23: <br />102 12 155 <br />ARCHITECTURE & PLANNING <br />CONTACT: Dan Craine, AIA <br />3080 LA IMER STREET <br />DENVER, CO 80205 <br />720.939.1199 <br />LANDSCAPE ARCHITECTURE <br />CONTACT: Paul Shoukas, RLA <br />`.vs group :r :... www.pcsgroupeo.com <br />#3 independence plazc : ESQ <br />1001 16th street . denver co 80265 <br />t 303 531 4905 . f 303 531 4908 <br />34 0 20 <br />36 0 15 <br />36 0 <br />0 <br />7 7 <br />14 14 <br />7 7 <br />0: 0 <br />170. 28 <br />1 <br />Total Parking PkgRatio <br />w/o Tand i w/ Tand w/o Tand t w/ Tand <br />55 55 1.7 1.7 <br />92 92 2.8 28 <br />72'.,72 2.2 2.2 <br />61.E 61 1.8 1.8 <br />19 49 56 1.5 1.7 <br />19 35� 49 1.2 1.6 <br />25 43 - 50 1.3 1.5 <br />0 23: 23 <br />105 430 458 1.9 2.0 <br />4141c5: tie <br />950 Spru :;9 Street, Suite 2A <br />Louisville, CO 80027 <br />Tel: (303) 475-2106 <br />LA, tact: Justin McClure <br />KEY MAP <br />BULK & DIMENSION STANDARDS <br />(MULTIFAMILY) <br />MIN. LOT AREA <br />MIN. LOT WIDTH <br />MAX. LOT COVERAGE <br />MIN. FRONT YARD SETBACK 3 <br />(PRINCIPAL USES) <br />MIN. SIDE YARD SETBACK a <br />(PRINCIPAL USES) <br />MIN. REAR YARD SETBACK'' <br />(PRINCIPAL USW. <br />SETBACK FROM COLLECTOR <br />STREET R.O.W. <br />SETBACK FROM LOCAL STREET <br />R.O.W. <br />MINIMUM BLDG. SEPARATION <br />A <br />PLANNING AREA 48 <br />MF: N/A SFA: 1.000 S.F <br />16' <br />85% <br />BUILDING SETBACKS' <br />6' ALL CONDITIONS <br />5' ALL CONDITIONS <br />4' (TO ALLEY) <br />PARKING: 15' <br />BUILDING,: 1.Q' <br />PARKING: 5' <br />BUIJ,p1NC: 5' <br />10' <br />MAX. BLDG. HEIGHT <br />PRINCIPAL USES MF:55' <br />BULK & DIMENSION STANDARDS <br />(ACCESSORY USES2) <br />1 PLANNING AREA 48 <br />BUILDING SETBACKS' <br />MIN. FRONT YARD SETBACK' 6' ALL CONDITIONS <br />MIN. SIDE YARD SETBACKS 5' (R.O.W.), <br />0' (INT. LOT UNE) <br />MIN. REAR YARD SETBACK' 5' (R.O.W.), <br />0' (INT. LOT UNE) <br />SETBACK FROM COLLECTOR <br />STREET R.O.W. <br />SETBACK FROM LOCAL STREET <br />R.O.W. <br />10' <br />5' <br />MINIMUM BLDG. SEPARATION 10' <br />MAX. BLDG. HEIGHT <br />ACCESSORY USES 35' <br />'DECKS OR PATIOS MAY ENCROACH 10' INTO REAR <br />SETBACK. <br />2ACCESSORY USES INCLUDE POOL AND COMMUNITY <br />RECREATIONAL FACILITIES, ACCESSORY <br />STRUCTURES AND FREE STANDING GARAGES. <br />PARKING STRUCTURES AND COVERED PARKING. <br />3ARCHITECTURAL FEATURES MAY ENCROACH INTO <br />BUILDING SETBACKS PER LMC 17.16.050. <br />STEEL RANCH SOUTH <br />FINAL DEVELOPMENT PLAN <br />PLANNING AREA 4B - PLAN, NOTES AND <br />STANDARDS <br />ENGINEERING <br />�'' CONSULTANTS <br />Contact: Jason D. Margraf, PE <br />6505 S. Paris St., Suite B - Centennial, CO 80111-6500 <br />(303) 368-5601- FAX: (303) 368-5603 <br />Email: Jmargraf@J3Engineering.net <br />4 06/18/12 <br />3 06/05/12 <br />2 05/18/12 <br />1 03/08/12 <br />No. Date <br />4TH SUBMITTAL <br />3RD SUBMITTAL <br />2ND SUBMITTAL <br />INITIAL SUBMITTAL <br />Description <br />DOCUMENT AMEN DM N rS <br />Project Number: <br />03000531 <br />Designed By: Drawn By: <br />ACE ACE <br />Checked By: <br />JDM <br />Sheet Number: <br />5of28 <br />