My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Business Center at CTC Replat F Amended CTC Commercial PUD Mylar
PORTAL
>
RECORDED PLATS (Mylars) and CITY MAPS
>
PUD (Planned Unit Developments)
>
C
>
CTC - Business Center at
>
Business Center at CTC Replat F Amended CTC Commercial PUD Mylar
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/5/2018 11:10:17 AM
Creation date
9/27/2017 1:40:05 PM
Metadata
Fields
Template:
CITYWIDE
Also Known As (aka)
CTC Commercial
Doc Type
Mylar
Ord/Res - Year
2017
Ord/Res - Number
30
Recordation Number
3613596
Subdivision Name
Business Center at CTC Replat F Amended
Signed Date
9/7/2017
Cross-Reference
PC Res 2017-10
Record Series Code
40.180
Record Series Name
Maps Drawings Plats Plans
Quality Check
10/11/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
( <br />Boulder County, CO 03613596 <br />81-0 <br />ST <br />m <br />78 =4 [ *GE OF EX/5T/NG BLDG TO EXT HALL FINISH] <br />0 <br />O <br />m <br />41-4 <br />8o1 -o [Our To aur] <br />8 EQ 5PACE5 = 801-0 <br />0 <br />PROPOSED FREEZER <br />6,261 SF <br />LkFLOOR <br />1001-0 = 5295.50 <br />801-0 (OUT TO OUT OF EXT !VALE F/N/51-0 <br />0 <br />ST T <br />/21-0 , 41-0 <br />� 1I <br />ET) i--- --- ii <br />f=— IlG re1 5=6 <br />I1 <br />I 1 <br />1 <br />I` <br />I <br />KEY NOTES <br />m <br />0 <br />(E) CONSTRUCTION TO REMAIN - TYPICAL <br />(E) CONSTRUCTION TO BE REMOVED - TYPICAL <br />(E) ASPHALT PAVING TO BE REMOVED AND <br />PATCHED - SEE CIVIL <br />(E) ASPHALT PAVING TO REMAIN <br />(E) CONCRETE APRON TO REMAIN <br />(E) WALL MOUNTED EXT LIGHT FIXTURE TO BE <br />REMOVED AND REINSTALLED <br />r l w w rot r•i1 <br />'-I 1 <br />m <br />0 <br />Oq <br />0 <br />0 <br />c.! <br />1 <br />ST ST 5,fr ST <br />\\`_ <br />(E) STORM SEWER LINE - SEE CIVIL <br />LINE OF EXTERIOR FACE OF ADDITION CONCRETE <br />FOUNDATION WALL - TYP <br />6"T STEEL FACED INSULATED FREEZER WALL PANEL <br />46" NOM WIDTH <br />6" CONC SLAB OVER RIGID INSULATION <br />36"W INSULATED DOOR CENTERED IN WALL PANEL <br />REMOVE EXISTING OH COILING DOOR AND INSTALL <br />INSULATED SLIDING DOOR ASSEMBLY <br />ST ST ST '5T <br />it <br />/ <br />�I <br />I <br />II <br />ii <br />II <br />I� <br />4T ' ST <br />02 <br />0 <br />/ <br />ST ST <br />II--- ----11 <br />it II <br />r z <br />DEACTIVATE (E) OH COILING DOOR IN OPEN POSITION <br />EXISTING OH COILING DOOR TO REMAIN IN CLOSED POSITION <br />EXISTING MAN DOOR TO BE LOCKED IN CLOSED POSITION <br />OPENING IN INSULATED WALL PANEL SYSTEM <br />RELOCATE (E) STORM SEWER MANHOLE - SEE CIVIL <br />NEW CONC CURB AND GUTTER - SEE CIVIL <br />6" CONCRETE CURB <br />CONC SIDEWALK <br />0 <br />28 <br />STEEL LANDING, STEPS AND RAILING <br />6x6 NOM METAL DOWNSPOUT <br />GONG SLAB <br />DOWNSPOUT TERMINATES IN CONC CHANNEL TO <br />CURB FLOWLINE <br />6"0 x 42"H CONC FILLED STEEL PIPE BOLLARD <br />2" RIVER ROCK MULCH OVER LANDSCAPE FABRIC <br />TO MATCH EXISTING IN AREAS DISTURBED BY <br />CONSTRUCTION OR WHERE EXISTING PAVING <br />HAS BEEN REMOVED - TYPICAL <br />/ <br />✓ <br />n <br />II <br />II <br />II <br />II <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />II <br />I I <br />I I <br />II <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />I I <br />REINSTALL REMOVED WALL MOUNTED LIGHT FIXTURE <br />QT T1.11c, I nr.4TIn1\I 41\Ir) 4'r amar L>=1AUT <br />0 <br />57 <br />8=0 <br />31-8 <br />R <br />ST <br />u <br />181-6 <br />u <br />u <br />161-0 <br />O <br />II <br />II <br />II <br />II <br />It <br />Sr <br />ST <br />n <br />11= i[FOUNDATION] <br />i' <br />METAL STUD FRAMED WALL CLOSURE TO HEAD OF <br />EXISTING OH DOOR OPENING. INFILL GAP WITH FIXED <br />STOREFRONT FRAMED GLASS PANEL <br />EXISTING EXIT DOOR TO REMAIN OPERABLE <br />5" CONCRETE SLAB ON GRADE <br />REFRIGERATION CONDENSING UNIT MOUNTED ON <br />CONC SLAB <br />6' -OH METAL SCREEN WALL - SEE DWG OI/A05 <br />EXISTING BUILDING <br />, <br />ST <br />ST <br />ST <br />c <br />h <br />21=0 <br />ST <br />ST <br />PROPOSED CONNECTION <br />1,410 SF <br />r <br />4,5 <br />EXISTING BUILDING <br />(E) FLOOR <br />100,-0 <br />0\ <br />00 <br />00 <br />0 <br />0a <br />a <br />00 <br />00 Es. <br />2,0000 <br />cd <br />O O\ <br />o d- <br />M <br />O <br />• en <br />A.� <br />p4 <br />cf' U <br />71-1 c+4 7:1cid <br />NI <br />U <br />CA <br />CA5 <br />cAU <br />H E-4 <br />U <br />E <br />I) <br />E <br />A02 <br />Sheet #3 of 10 <br />02/0.2/1"1 SUBMITTAL <br />04/14/I1 RESUBMITTAL #1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.