My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Park at CTC Lot 1 Block 1 Amendment 1 PUD Mylar
PORTAL
>
RECORDED PLATS (Mylars) and CITY MAPS
>
PUD (Planned Unit Developments)
>
C
>
CTC - The Park at
>
Park at CTC Lot 1 Block 1 Amendment 1 PUD Mylar
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 9:19:27 AM
Creation date
3/8/2018 12:58:53 PM
Metadata
Fields
Template:
CITYWIDE
Doc Type
Mylar
Recordation Number
3643183
Subdivision Name
Park at CTC
Property Address Number
1699
Property Address Street Name
Cherry
Parcel Identification Number
157516015001
Record Series Code
40.180
Record Series Name
Maps Drawings Plats Plans
Quality Check
3/8/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1 <br />co <br />nr <br />co <br />CV) <br />O <br />0 <br />a <br />c <br />0 <br />-73 <br />O <br />m <br />SS BIKE <br />RACK <br />CONCRETE <br />PAVING <br />BIKE RACK AND BENCH PERSPECTIVE <br />SCALE: <br />RESERVED <br />PARKING <br />12"x18" <br />MINIMUM SIZE <br />MUTCD R7-8 <br />ACCESSIBLE PARKING SIGN <br />NOT TO SCALE <br />BOARD FORM CONCRETE <br />CONCRETE, PAINT TO <br />MATCH BUILDING <br />1 <br />1/2" THICK <br />ACRYLIC LETTERS, <br />BLACK, TYP <br />M <br />METAL 'L' SHAPE, <br />PAINTED BLACK <br />STONE VENEER <br />0 <br />RESERVED <br />PARKING <br />H VAN i� <br />ACCEISISIBLE <br />u <br />6"x12" <br />MINIMUM SIZE <br />MUTCD R7 -8B <br />VAN ACCESSIBLE PARKING SIGN <br />NOT TO SCALE <br />SIGN LEGEND <br />NOT TO SCALE <br />UILDING NAME <br />)(XXX <br />l:l i�;^:'.� . l.:f'%.ill f..`i.... <br />MONUMENTAL SIGN ELEVATION <br />SCALE: 1/2" =1'-0" <br />MONUMENT SIGN PLAN <br />SCALE: 1/2" =1'-0" <br />2" <br />6'-0" <br />6'-0" <br />8'-0" <br />8'-0" <br />2" <br />1'-8"11, <br />'��� 2"REVEAL <br />1'-8" <br />1/2" THICK ACRYLIC <br />LETTERS BLACK, TYP <br />VARIES W/ GRADE <br />• <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO <br />LOT 1, BLOCK 1 - THE PARK AT C.T.C. FIRST FILING - 1ST AMENDMENT <br />TRASH ENCLOSURE SECTION <br />SCALE: 3/8" =1'-0" <br />TRASH ENCLOSURE ELEVATION <br />SCALE: 3/8" =1'-0" <br />11'-4" <br />10'-0" <br />10 CY TRASH CONTAINER <br />CONCRETE TILT WALL <br />PANEL, PAINTED TO <br />MATCH FIELD COLOR <br />CONCRETE SLAB <br />CONCRETE FOOTING <br />NOTE: <br />ALL GATE AND FRAME <br />SURFACES TO HAVE <br />PAINTED FINISH <br />4"x4"x114" STEEL TUBE, <br />PAINTED <br />3"x3"x114" ANGLE FRAME <br />1/2" DIA. HORIZONTAL CANE <br />BOLT GATE LOCK <br />22 GA. GALV STEEL DECK <br />PROFILE "B" W/ 4" RIB <br />SPACING <br />1/2" DIA. VERTICAL CANE <br />BOLT W/ STEEL SLEEVE AT <br />SLAB <br />0 <br />TRASH ENCLOSURE PLAN <br />SCALE: 3/8" =1'-0" <br />00 <br />c <br />GALVANIZED <br />STEEL GATE, <br />PAINTED <br />PARKING <br />BUMPER <br />TRASH <br />CONTAINER <br />TILTWALL <br />PAINTED <br />RAMP LOCATION <br />AT OUTSWING DOOR <br />AT INSWING/SLIDING DOOR <br />NO DOORWAY <br />MINIMUM DIMENSION <br />A B <br />44" 60" <br />44" 48" <br />36" 36" <br />NOTES: <br />1. ALL ACCESSIBLE COMPONENTS CONSTRUCTED AS PART OF <br />THESE PLANS SHALL COMPLY WITH THE LOCAL BUILDING <br />CODE. <br />2. ACCESSIBLE ROUTE TO ACCESSIBLE SPACES, BUILDING <br />ENTRANCES, AND PUBLIC STREETS SHALL NOT EXCEED 5% <br />RUNNING SLOPE AND 2% CROSS SLOPE. <br />3. CHANGE IN ELEVATION WITHIN THE ACCESSIBLE ROUTE IS <br />NOT TO EXCEED kz" WITHOUT A CURB RAMP. <br />4. UNLESS OTHERWISE SHOWN ON THE PLANS, THE MINIMUM <br />CLEAR ROUTE SHALL BE 36" WIDE WITH A 60"x60" PASSING <br />SPACE EVERY 200 FEET. <br />5. ACCESSIBLE ROUTES THROUGH PLANTERS SHALL BE LEVEL <br />WITH THE SURROUNDING PAVEMENT OR PROVIDE CURB <br />RAMPS AT EACH END WITH A MINIMUM 48" LEVEL LANDING <br />IN BETWEEN. <br />6. THE ACCESSIBLE ROUTE IN FRONT OF PULL—IN PARKING <br />SHALL BE A MINIMUM OF 44" WIDE AND NOT REDUCED BY <br />VEHICLE OVERHANGS, CURBING, SIGN POSTS, OR OTHER <br />OBSTRUCTIONS. <br />7. ANY WALK THAT CROSSES OR ADJOINS A VEHICULAR WAY <br />NOT SEPARATED BY CURBS, RAILINGS, OR OTHER ELEMENTS <br />SHALL BE DEFINED BY A CONTINUOUS 36" WIDE DETECTABLE <br />WARNING. DETECTABLE WARNING <br />(SEE NOTE 9) <br />8. CURB RAMPS SHALL HAVE A DETECTABLE WARNING <br />EXTENDING THE FULL WIDTH AND DEPTH OF THE RAMP <br />GQ` <br />9. DETECTABLE WARNINGS SHALL CONSIST OF CAST IRON <br />PLATES FROM NEENAH FOUNDRY. VERIFY LOCAL <br />REQUIREMENTS WITH THE BUILDING DEPARTMENT. <br />z <br />-J <br />CL <br />W <br />a. <br />cD <br />z <br />J <br />Hl.I,tJJIDLE J�ALL <br />WIDTH PER PLAN <br />(8' MIN) <br />n <br />- 2' <br />PIPE BOLLARD <br />(REF: NOTE 5) <br />(TYPICAL) <br />ACCESSIBLE RAMP DETAIL <br />NOT TO SCALE <br />ACCESS AISLE <br />11ETH IER FL, -,Id <br />(5' MIN STANDARD) <br />(8' MIN VAN ACCESS) <br />• <br />v <br />ALL DIRECTIONS <br />ALLtJJICLt J 1 ALL <br />WIDTH PER PLAN <br />(8' MIN) <br />ACCESS AISLE SHALL <br />BE DIAGONAL STRIPING <br />(REF: NOTE 6) <br />CURB & GUTTER WHERE <br />APPLICABLE <br />(REF: NOTE 4 FOR CURB & <br />GUTTER REQUIREMENTS) <br />ACCESSIBLE PARKING SIGN <br />IN BOLLARD <br />(REF: SIGNAGE AND SIGN <br />MOUNT DETAIL) <br />INTERNATIONAL ACCESSIBLE <br />PARKING SYMBOL <br />(VAN ACCESSIBLE DESIGNATION <br />WHERE APPLICABLE) <br />NOTES <br />1. EACH ACCESSIBLE PARKING SPACE IS TO BE A MINIMUM OF 8 FEET WIDE AND HAVE A 96" MINIMUM ACCESS AISLE FOR VANS OR 60" ACCESS AISLE FOR CARS ADJACENT TO THE SPACE. <br />2. CONSTRUCTED SLOPES WITHIN THE ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL NOT EXCEED 1:50 (2%) IN ANY DIRECTION. <br />3. RAMPS MUST NOT EXTEND OUT FROM THE CURB INTO THE ACCESS AISLE OF ANY ACCESSIBLE PARKING SPACE. <br />4. CURB AND GUTTER ADJACENT TO OR WITHIN ACCESSIBLE PARKING STALLS SHALL BE MODIFIED IN A MANNER THAT THE SLOPE CONSTRUCTED WITHIN THE GUTTER PAN SHALL NOT EXCEED 1:50 <br />OR (2%) SLOPE IN ALL DIRECTIONS. <br />5. PIPE BOLLARDS SHALL BE INSTALLED WITHIN ACCESS AISLE AND ADJACENT STALLS PER PIPE BOLLARD DETAIL. MINIMUM CLEARANCE BETWEEN BOLLARDS SHALL BE 36". MAXIMUM CLEARANCE <br />BETWEEN BOLLARDS SHALL BE 60". <br />6. SURFACE STRIPING PAINT SHALL BE FS—TT—P-1952D (WATERBORNE), TYPE II ADVERSE CONDITIONS, COLOR: HIGHWAY YELLOW OR AS REQUIRED BY LOCAL CODES. <br />ACCESSIBLE PARKING DETAIL <br />NOT TO SCALE <br />w <br />z <br />0 <br />a <br />w <br />1- <br />z <br />0 I <br />U 0 <br />a <br />1ST AMENDMENT <br />r r <br />2 <br />0 <br />z <br />z <br />LY <br />O <br />z <br />w <br />0 <br />N <br />CD <br />4582 South Ulster <br />z <br />O <br />0 <br />0 <br />N <br />CO <br />N <br />N <br />0 <br />r`- <br />0 O <br />0 <br />Denver, Colorado <br />DESIGNED BY: DLS <br />DRAWN BY: STC <br />CHECKED BY: DS <br />DATE: 01/01/2018 <br />W <br />0 <br />0 <br />z_ <br />J_ <br />LL <br />LL <br />U O <br />. <br />HQ <br />Li L WO <br />QUO <br />z <br />W <br />a. 2J <br />W Q J <br />5 <br />0 <br />J <br />0 <br />0 <br />m <br />0 <br />J <br />PROJECT NO. <br />096501001 <br />DRAWING NAME <br />DETAILS <br />13 <br />o <br />
The URL can be used to link to this page
Your browser does not support the video tag.