ima <br />Lou sville <br />• Natural Lighting <br />o Commercial Buildings need 3% of Roof to be skylights unless <br />used for solar panels <br />o Commercial glazing shall not be less than <br />• Air Changes <br />o All New Residential shall be tested to verify air leakage rate <br />does not exceed 3 air changes an hour and shall have whole <br />house mechanical ventilation with section M1505.4. <br />Snow Load: <br />Wind speed: <br />Wind Exposure: <br />Seismic Zone: <br />Frost line depth: <br />Weathering: <br />Termite: <br />Decay: <br />Winter Design Temp: <br />Anticipated Snow: <br />Ice & Water Shield: <br />Solar Design: <br />Drip Edge: <br />Air Freezing Index: <br />Mean Annual Temp: <br />Elevation: <br />Current code: <br />DESIGN CRITERIA <br />30 I bs/sf <br />115 mph for 3 second gust <br />100 mph fastest mile <br />D3161 test with Class F Application <br />"C" until proven otherwise for greater restrictions <br />B <br />36" below finished grade (LMC 15.05.050) <br />Severe — Climate Zone 5B <br />Slight <br />Slight <br />1 degree <br />6" <br />Required on ALL Shingled Roofs — Eaves only <br />Must extend from the lowest edges to a point at least 24" inside the exterior wall line of the building. <br />High Temp =2% AVG. 34 Deg C Extreme Min= -23 Deg C <br />Required on both eaves and rakes of roof. <br /><1000 <br />47 degrees <br />5,337 feet above sea level. <br />2018 IBC, IRC, IFC, IPC, IFGC, IMC, IECC, IEBC, IPMC, 1997 Uniform Code <br />for the Abatement of Dangerous Building Code and NEC 2017 <br />Remember: <br />Sump Pumps: Can NOT drain into sanitary or storm sewer. <br />Daylight into lawn away from foundation. <br />Perimeter foundation systems go to sump pit then sump pump and sump <br />pump to lawn. <br />Drainage from House: Slope at least 6" in the 1st 10 feet. <br />Retaining Walls: Less than 48" from the bottom of the footing to top the retaining wall with <br />no surcharge does not require a permit. <br />Over 48" from the bottom of the footing to top the retaining wall, or ANY <br />wall with surcharge, requires stamped engineered plans. <br />Backflow Preventer: Required on residential irrigation systems. (See cross connection control manual) <br />Hot Water Heaters: Require expansion tanks for ALL hot water heaters. <br />Required to have a drain pan if placed on a wood floor. <br />www.iccsafe.orq for International codes, books, licensing etc. <br />www.energycodes.gov/rescheck or just google rescheck <br />www.epa.gov for fireplaces look under woodstoves or cdphe.state.co.us <br />