My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Building Code Board of Appeals Agenda and Packet 2013 09 19
PORTAL
>
BOARDS COMMISSIONS COMMITTEES RECORDS (20.000)
>
BUILDING CODE BOARD OF APPEALS
>
2000-2019 Building Code Board of Appeals Agendas and Packets
>
2013 Building Code Board of Appeals Agendas and Packets
>
Building Code Board of Appeals Agenda and Packet 2013 09 19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 2:00:20 PM
Creation date
6/25/2018 10:58:53 AM
Metadata
Fields
Template:
City Council Records
Doc Type
Boards Commissions Committees Records
Supplemental fields
Test
BCBOAPKT 2013 09 19
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Section 101.1 of the 2012 International Residential Code is amended to insert <br />"the City of Louisville" so the section will read: <br />R101.1 Title. These provisions shall be known as the Residential Code for One- and <br />Two -Family Dwellings of the City of Louisville, and shall be cited as such and will be <br />referred to herein as this code. <br />Sec. 15.05.040. Section R108.2 Schedule of permit fees. <br />Section R108.2 of the code shall read as follows. <br />R108.2 Schedule of permit fees. On buildings, structures, electrical, gas, mechanical <br />and plumbing systems or alterations requiring a permit, a fee for each permit shall be <br />paid as required, as set forth in the fees established by the current adopted annual fee <br />resolution for the Cityof Louisville,Colorado <br />Sec. 15.05.050. Table R301.2(1) revised. <br />Table R301.2(1) is filled in as follows: <br />TABLE R301.2(1) <br />CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br />Ground <br />Snow <br />Load <br />Wind <br />Speed <br />(mph) <br />Seismic <br />Design <br />Category <br />Subject to Damage From <br />Winter <br />Design <br />Temp. <br />Ice <br />Shield <br />Under - <br />Layment <br />Required <br />Flood <br />Hazards <br />Air <br />Freezing <br />Index <br />Mean <br />Annual <br />Temp. <br />Weathering <br />Frost <br />Line <br />Depth <br />Termite <br />Decay <br />30 <br />Lbs./s.t. <br />100-B <br />115 <br />Severe <br />36" <br />Slight/Moderate <br />Slight/Moderate <br />1° <br />Yes <br />2012 <br />1000- <br />2000 <br />47° <br />Section 15.05.080. Section P3103.1 amended. <br />The number "12" is inserted in two locations of Section P3103.1 so the section <br />will read as follows: <br />P3103.1. Roof extension. Alt open vent pipes which extend through a roof shall be <br />terminated at least 12 inches above the roof or 12 inches above the anticipated snow <br />accumulation, except that where a roof is to be used for any purpose other than weather <br />protection, the vent extensions shall be run at least 7 feet (2134 mm) above the roof. <br />Sec. 15.05.100. Copies available. <br />At least one copy of the International Residential Code and one copy of each <br />secondary code pertaining thereto, as amended herein, all certified to be true and <br />accurate, shall be available for public inspection at the office of the Building Safety <br />7 <br />