Laserfiche WebLink
Amendments to the International Plumbing Code <br /> Ordinance Amending Chapter 15 16 of the Louisville Municipal Code <br /> 1 Excluding trap arm. <br /> 2 Except sinks, urinals and dishwashers <br /> 3 Except six-unit traps or water closets <br /> 4 Only four(4)water closets or six-unit traps allowed on any vertical pipe or stack, and <br /> not to exceed three (3)water closets or six-unit traps on any horizontal branch or <br /> drain <br /> 5 Based on one-fourth (1/4) inch per foot slope. For one-eighth (1/8) inch per foot <br /> slope, multiply horizontal fixture units by a factor of 0 8 <br /> Note: The diameter of an individual vent shall not be less than one and one-fourth (1-1/4) <br /> inches nor less than one-half(1/2)the diameter of the drain to which it is connected <br /> Fixture unit load values for drainage and vent piping shall be computed from Tables 709.2 <br /> and 710 1(1) Not to exceed one-third (1/3) of the total permitted length of any vent may be <br /> installed in a horizontal position When vents are increased one (1) pipe size for their entire <br /> length, the maximum length limitations specified in this table do not apply <br /> Table 710.1(2)—Horizontal Fixture Branches and Stacks. Delete Table 710.1(2) in <br /> its entirety <br /> Section 711 —Offsets in Drainage Piping in Buildings of Five Stories or More. <br /> Delete Section 711 in its entirety. <br /> Section 712.2—Check and Gate Valve Required. Exception. Delete the Exception in <br /> its entirety <br /> Section 712.3.1 —Sump Pump. Amend by adding a sentence to read as follow "Dual <br /> pumps are required and shall be arranged to function independently in case of mechanical <br /> failure except that single-family residential occupancies may have single pump if an <br /> approved sensor and alarm system is installed. <br /> Section 712.4.1 —Capacity. Exception. Delete the Exception in its entirety <br /> Section 714—Computerized Drainage Design. Delete Section 714 in its entirety <br /> Section 802.4—Standpipes. Amend by adding a sentence as follows- "Standpipe traps <br /> shall not be located below the floor" <br /> Section 901.6—Engineered Systems. Delete Section 901 6 in its entirety <br /> Section 904.1 —Roof Extension. Amend by insertion of the number "6" inches and <br /> "152 4" mm in the brackets <br /> Section 904.6—Extension Through the Wall. Delete Section 904 1 in its entirety. <br /> Section 905.1 —Connection. Exception. Delete the Exception in its entirety <br /> Section 905.6—Side Inlet. Delete Section 905.6 in its entirety and amend as follow. <br /> "Side inlet quarter bends are prohibited." <br />