Laserfiche WebLink
Boulder County, CO 03746760 6 of 7 <br />RIM EL = 5348.51 <br />INV IN(N) = 5337.39 <br />INV OUT(S) = 5337.37 <br />JEFFERSON PLACE <br />SUBDIVISION <br />oo <br />N <br />cn <br />to <br />Cl1 <br />cn <br />v7 <br />S4 <br />RIM EL = 5342.70 <br />INV IN(N) = 5330.00 <br />INV OUT(S) = 5329.84 <br />0 <br />1 <br />INV EL=5346.4' <br />SOUTH STREET <br />3 3 <br />it ----- G----3--- G --- <br />40,wir __________ <br />ffittritM\ 41) <br />SOUTH HALF <br />LOT 2 <br />W W - W W W <br />ST ST ST -ST <br />- e G <br />S3 <br />0 <br />0 <br />0 <br />W <br />0 <br />iv <br />0 <br />ST <br />)r <br />Scale: 1" = 10' <br />0 5 10 <br />20 <br />LEGEND <br />0 UTILITY POLE <br />TE TELEPHONE BOX <br />EM ELECTRIC METER <br />GM GAS METER <br />UC UTILITY CONNECTION <br />LF LINEAR FEET <br />CENTERLINE <br />LP LIGHT POLE <br />BR BIKE RACK <br />b SIGN <br />CS WATER CURB STOP <br />CO CLEANOUT <br />MANHOLE <br />45.4x SPOT ELEVATION <br />41.2fI x SPOT ELEVATION AT FLOWLINE <br />CHAIN LINK FENCE <br />WOOD FENCE <br />METAL FENCE <br />0 0 0 <br />OVERHEAD UTILITY LINES <br />GAS LINE <br />WATER LINE <br />W W <br />SANITARY SEWER LINE <br />SS SS <br />STORM LINE <br />ST ST <br />UNDERGROUND ELECTRIC LINES <br />-----E-----E----- <br />012" <br />DECIDUOUS TREE <br />WITH TRUNK DIAMETER <br />12" <br />JUNIPER TREE <br />WITH TRUNK DIAMETER <br />5b FIVE BOLE TREE <br />&, HANDICAP RAMP <br />DOWN SPOUT <br />KEYED NOTES O <br />1. PROPOSED SANITARY SEWER SERVICE. <br />2. PROPOSED GREASE TRAP. <br />3. PROPOSED WATER SERVICE. <br />4. PROPOSED WATER METER AND CURB STOP VALVE. <br />5. PROPOSED UNDERGROUND POWER. <br />6. EXISTING GAS LINE TO REMAIN. <br />7. RELOCATE POWER POLE. <br />8. EXISTING GAS LINE TO REMAIN. IF POSSIBLE, STUB OFF OF EXISTING LINE <br />FOR NEW BUILDING SERVICE. <br />9. PROPOSED 4" FIRE SERVICE. <br />10. RELOCATED GAS METER. <br />11. APPROXIMATE LOCATION OF EXISTING SANITARY SEWER SERVICE TO BE <br />REMOVED AND CAPPED. <br />12. EXISTING WATER METER AND LINE TO BE ABANDONED IN PLACE. <br />13. PROPOSED SIDEWALK DRAIN PIPE. CITY OF LOUISVILLE DETAIL. <br />14. PROPOSED ROOF DRAIN. <br />15. PROPOSED UTILITY EASEMENT. <br />UTILITY NOTES <br />1. ALL CITY UTILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF LOUISVILLE <br />STANDARD SPECIFICATIONS. <br />2. WATER, FIRELINE, SEWER TAPS, AND SERVICE LINE SIZES SHALL BE DETERMINED AT THE TIME <br />OF BUILDING PERMIT APPLICATION. <br />3. ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE DONE IN A WAY SO AS TO MINIMIZE <br />DISRUPTION IN SERVICE TO EXISTING USERS. <br />4. THE LOCATION OF THE ABOVE GROUND UTILITIES SHOWN HEREON ARE BASED ON THE FIELD <br />SURVEY BY FLAGSTAFF SURVEYING, INC.. THE LOCATIONS OF THE UNDERGROUND UTILITIES <br />SHOWN HEREON ARE BASED ON SAID SURVEY AND INFORMATION PROVIDED BY OTHERS <br />(WHICH MAY INCLUDE THE UTILITY OWNER OR UTILITY LOCATING SERVICES). SCOTT, COX & <br />ASSOCIATES, INC. IS NOT RESPONSIBLE FOR UTILITY INFORMATION PROVIDED BY OTHERS. <br />SCOTT, COX & ASSOCIATES, INC. RECOMMENDS THAT THE LOCATION OF THE UTILITIES BE <br />FIELD VERIFIED PRIOR TO ANY DIGGING ON, OR ADJACENT TO THE SUBJECT PROPERTY. <br />5. BENCHMARK: NORTHWEST BONNET BOLT OF FIRE HYDRANT LOCATED AT THE NORTHEAST <br />CORNER OF MAIN STREET AND SOUTH STREET, ELEVATION = 5344.98 FEET, CITY OF <br />LOUISVILLE DATUM PER FLAGSTAFF SURVEYING, INC. DRAWING 17122A-1, DATED NOVEMBER <br />26, 2014. <br />./rr <br />scam cox & ASSOCIATES, NC. <br />consulting engineers • surveyors <br />1530 55th Street • Boulder, Colorado 80303 <br />(303) 444 - 3051 <br />DWG NO. 154458-4 <br />a <br />_. <br />HS <br />EVEI <br />J`� q <br />4 ,e <br />ti <br />rJ� • <br />PROJECT # 1551 <br />DATE: 5/25/16 <br />DRAWN BY: JAS <br />CHECKED BY: DM5 <br />REVISIONS: 02-12-11 <br />PUD AMENDMENT 04/OI/I4i <br />PUD AMENDMENT OS/08/1 q <br />BUD AMENDMENT 08/24i/I61 <br />COPYRIGHT 2015 <br />All drawn and written information <br />duplicated disclosed or otherwise <br />appearing herein shall not be <br />used without written consent of <br />Hartronft Associates, p.c. <br />PRELJMINARY <br />UTLITY PLAN <br />Sheet <br />c1.01 <br />of Sheets <br />