Laserfiche WebLink
Maximum Air leakage rate for all fenestration except curtain walls <br />and storefront glazing <br />.20 cfm/ft2 <br />Maximum air leakage rate for curtain walls and storefront glazing <br />.06 cfm/ft <br />Skylights <br />Maximum U-Factor <br />0.50 <br />Maximum SHGC <br />0.40 <br />Maximum Air leakage rate <br />.20 cfm/ft2 <br />11. Section C402.4.1 Maximum area, is hereby deleted and replaced in its <br />entirety and the following is hereby added in lieu thereof: <br />C402.4.1 Minimum area of natural lighting. Not less than eight percent <br />of the floor area shall be glazed. <br />12. Section C402.4.2 Minimum skylight fenestration area, is hereby deleted <br />and replaced in its entirety and the following is hereby added in lieu thereof: <br />C402.4.2 Minimum area of natural lighting. A minimum skylight area of <br />three percent of the roof area shall be provided for all roofs. <br />Exception: Roof areas designated for solar ready zones shall not be included in <br />roof area calculation. <br />13. Section C403.3.2 HVAC equipment performance requirements, is hereby <br />retained in its entirety with the following amendments: <br />C403.3.2 HVAC equipment performance requirements. <br />iumuw�wuwME <br />�� <br />i <br />'1�1G <br />wrrx��wr� <br />0 <br />