Laserfiche WebLink
Boulder County, CO <br />03919483 <br />4 of 12 <br />EXISTING STO <br />INLET <br />EXISTING FI <br />HYDRANT <br />EXISTIN <br />DRAINAGE <br />CHANNEL <br />10:0' UTILITY <br />EASEMENT <br />50.0' DRAINAG <br />:::EASEMENT <br />X <br />P <br />XGAs -- XGAS J . . <br />LAS <br />0 <br />X <br />0 <br />4 <br />C <br />MX <br />MX <br />- CONNECT TO <br />EXISTING <br />B" WATER MAIN <br />FIRE HYDRANT <br />LOT COLORADO TECHNOLOGICAL CENTER FILING NO. 2 REPLAT D LEGEND: <br />EXISTING STREET LIGHT(IV, <br />XGAS :MA <br />771 <br />EXISTING STORM INLET <br />EXISTING DUAL 48" RCP STORM <br />EXISTING FIBER OPTICS <br />MX MX <br />OAX MX MX <br />EXISTING FIRE HYDRANT <br />PLANNED UNIT DEVELOPMENT <br />THE COMBINATION OF LOT 1 AND LOT 2, COLORADO TECHNOLOGICAL CENTER FILING NO. 2, <br />LOCATED IN THE SOUTHEAST ONE -QUARTER OF SECTION 16, TOWNSHIP 1 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO <br />UNINCORPORATED <br />BOULDER COUNTY <br />PARCEL <br />CONNECT TO EXISTING 8" <br />SANITARY SERVICE STUB <br />XGAS <br />EXISTING GAS SER <br />XGAS XGAS <br />IAX <br />CONNECT TO EXISTING-24" <br />WATER SERVICE <br />MX <br />MX <br />EXISTING SANITARY MI( <br />10;0': UTILITY <br />POND OUTLET STRUCTURE <br />CONNECT TO TING <br />8" WATER STUB <br />f3t4V <br />EXISTING 18" RCP STCTR4 <br />CTC BOULEVARD <br />60' R.O.W. <br />EXISTING STORM MI-1/ <br />EXISTING ELEC. EQUIPMENT <br />EXISTING 8" PUBLIC WATER MAIN <br />EXISTING FIRE <br />f\X PAX PAX <br />PAX MX <br />RETAINING WALLS <br />EXISTING 8" SANITARY MAIN I <br />EXISTING 30* RCP STORIA_ EXISTING 12" WATER MAIN <br />EXISTING 2" WATER SERVICE <br />STUB TO BE USED FOR IRRIGATION <br />OX <br />• <br />• <br />SVOX <br />EXISTING STORM MI/ <br />• <br />8L. UTILITY EASEMENT <br />FILING 2 <br />LOT 3 <br />EXISTING 36" RCP STORM <br />EXISTING 8" SANITARY STU <br />FOR FUTURE EXTENSION <br />EXISTING STORM INLET <br />EXISTING 8" <br />PRIVATE WA'TE <br />MAIN <br />EXISTING STORM INLE <br />EXISTING 18" RCP STO <br />STUB TO BE ABANDON <br />74--- EXISTING 24" RCP STO <br />EXISTING 30" RCP STOI <br />EXISTING FIRE HYDRANT <br />SD> <br />XW <br />rr <br />XS> -410- <br />XE <br />XOH <br />XPHON <br />XGAS <br />XIRR <br />XFO <br />NOTES: <br />PROPERTY LINE <br />PROPOSED BUILDING <br />EXISTING BUILDING <br />PROPOSED EASEMENT <br />EXISTING EASEMENT <br />PROPERTY SETBACK <br />PROPOSED STORM LINE <br />EXISTING STORM LINE <br />PROPOSED INLET <br />EXISTING INLET <br />PROPOSED WATER LINE <br />EXISTING WATER LINE <br />PROPOSED HYDRANT & VALVE <br />EXISTING HYDRANT & VALVE <br />PROPOSED SAN SEWER LINE <br />EXISTING SAN SEWER UNE <br />EXISTING ELECTRICAL LINE <br />EXIST. OVERHEAD ELEC. LINE <br />EXISTING TELECOMM LINE <br />EXISTING GAS LINE <br />EXISTING IRRIGATION LINE <br />EXISTING FIBER OPTIC LINE <br />PROPOSED LIGHT <br />EXISTING LIGHT <br />> ce <br />U <br />0: <br />CL <br />600 Grant Street I Suite 21 D I Denver, CO <br />FOR AND ON BEHALF OF PROOF CIVIL CO, <br />0 <br />1. DAMAGES TO THE STREET LIGHT ON THE <br />NORTHWEST SIDE OF THE SITE, CAUSED BY USE GF <br />EASEMENT FOR DRAINAGE OR UTILITY PURPOSES <br />SHALL BE REPAIRED BY PROPERTY OWNER_ <br />2. ON -SITE WATER LINE AND STORM SEWER LINES <br />SHALL BE MAINTAINED BY THE PROPERTY OWNEF <br />SCALE: 1" = 30' <br />DESCRIPTION <br />CITY COMMENTS <br />C\I OP <br />CO <br />CD <br />iNJ <br />DRAWN BY: <br />DRAWING NO. <br />4 <br />LLI <br />Z <br />id <br />UJ <br />CHECKED BY: <br />4 OF 12 <br />COLORADO <br />