Laserfiche WebLink
Boulder County, CO <br />03974886 <br />3of7 <br />LOT 2 <br />CENTENNIAL VALLEY BUSINESS PARK <br />PARCEL NO. 157713011003 <br />7.....:ZCI <br />z z <br />W <br />Ar <br />LU <br />0� <br />0 <br />NORTHING: 1231428.21 <br />EASTING: 3085510.32 <br />/ <br />/ <br />NORTHING: 1231379.21 <br />EASTING: 3085543.48 <br />sr ` <br />_ -5580- <br />`FG: 5578.90 <br />PROPOSED SIDEWALK CHASE <br />4tFG:5578.90 <br />NORTHING: 1231415.96= - V <br />EASTING: 3_085597.78 Th <br />e . ` ����ccME: 79.32 <br />" �-,": FFE: 5579.50 <br />FFE: 5579.50 <br />. i *rfr <br />j <br />FFE: 5579.50 <br />FG: 5578.47 <br />ME: ±5578.14 -- <br />. 5578.51 <br />ME <br />ME. ±5578.24 <br />-�-FG: 5578.66 - <br />PROPOSED SIDEWALK CHASE <br />4FG:5578.78 <br />FG: 5578.82- <br />FG: 5579.00 7 <br />n, ME: ±5575.69 <br />in tI Lo <br />FG:5579.00 4 <br />s FG: 5578.90 , <br />±5577.94 <br />6° ME: ±5578.03 <br />FFE: 5579.50 <br />NORTHING: 1231282.79 <br />EASTING: 3085687.90 <br />EXISTINC <br />DOOR (TYP) <br />NORTHING: 1231246.00 <br />EASTING: 3085633.54 <br />EXISTING STAIRS <br />TO REMAIN <br />EXISTING SIDEWALK <br />TO REMAIN <br />LOT 1 <br />CENTENNIAL VALLEY <br />BUSINESS PARK PARCEL NO. <br />157713102001 <br />NORTHING: 1230983.18 <br />EASTING: 3085521.06 <br />1A <br />''•`in obe <br />ms, <br />i • r <br />'.11111t11.1 P a <br />=. ? :i <br />, <br />NORTHING: 1231025.11 <br />EASTING: 3085583.01 <br />Know what's below. <br />Call before you dig. <br />NORTHING: 1231006.39 <br />EASTING: 3085595.68 <br />ME:±5578.00 <br />ME: ±5577,98_ CONTRACTOR TO PROTECT <br />EXISTING TREES IN PLACE <br />NORTHING: 1231126.51 <br />EASTING: 3085731.67 <br />NORTHING: 1231118.49 <br />EASTING: 3085719.83 <br />NORTHING: 1231088.24 <br />EASTI NG: 3085703.05 <br />NORTHING: 1231081,94 <br />EASTING: 3085707.31 <br />NORTHING: 1231021.097 <br />EASTING: 3085603.84 <br />NORTHING: 1231014.80 <br />EASTING: 3085608.10 <br />/ <br />/ <br />PROPERTY LINE <br />NORTHING: 1231107.13 <br />EASTI NG: 3085744.79 <br />I <br />I <br />1 <br />I <br />I <br />I <br />I <br />I <br />/ I <br />// 1 <br />/ / <br />I I <br />I Il <br />/ I i 1/ <br />I <br />/ <br />1I1 <br />11 <br />1 1/ <br />I <br />1 <br />1 <br />I <br />1 <br />/ <br />/ <br />/ 1 <br />II / <br />1 11/ <br />11 <br />/ I ►I <br />lI 1 <br />I I 1 <br />1 <br />/I I// <br />GRAPHIC SCALE IN FEET <br />0 15 30 60 <br />LEGEND: <br />----xx---- <br />''X <br />xx <br />AR <br />X.XX% _ <br />PROPERTY LINE <br />EXISTING EASEMENT UNE <br />EXISTING MAJOR CONTOURS <br />EXISTING MINOR CONTOURS <br />PROPOSED MAJOR CONTOURS <br />EXISTING MAJOR CONTOURS <br />ACCESSIBLE ROUTE <br />LIMITS OF DISTURBANCE <br />SLOPE ARROW <br />EXISTING LIGHT POLE <br />EXISTING TREES TO REMAIN <br />I EXISTING GRAVEL <br />I PROPOSED SIDEWALK CONCRETE <br />I EXISTING CONCRETE <br />.W.W. I PROPOSED LANDSCAPE AREA <br />FG FINISHED GRADE <br />ME MATCH EXISTING <br />FFE FINISHED FLOOR ELEVATION <br />SITE PLAN NOTES: <br />1. THE PURPOSE OF THIS 1ST PUD AMENDMENT IS TO ADDRESS THE <br />EXTERIOR CHANGES TO THE EASTERN ELEVATION OF THE BUILDING AND <br />ASSOCIATED LANDSCAPING AT 1450 INFINITE DRIVE. THIS AMENDMENT <br />DOES NOT REPLACE OR SUPERSEDE THE 'CENTENNIAL VALLEY BUSINESS <br />PARK QUANTUM PUD' OTHER THAN TO UPDATE SITE DATA TO <br />ACCURATELY REFLECT THE CHANGES TO LANDSCAPING AND SITE <br />COVERAGE AND TO PERMIT THE EXTERIOR ALTERATIONS. <br />2. PROPOSED IMPROVEMENTS ARE PRIVATE. CITY OF LOUISVILLE IS NOT <br />RESPONSIBLE FOR THE MAINTENANCE OF PROPOSED IMPROVEMENTS. <br />3. EXISTING GRADES ARE PER THE TOPOGRAPHIC SURVEY CONDUCTED BY <br />DREXEL, BARREL & CO. PROVIDED TO KIMLEY-HORN ON 03/29/2022. <br />4. CONTRACTOR TO CONFIRM TIE-IN LOCATIONS AND FFE PRIOR TO <br />CONSTRUCTION. NOTIFY ENGINEER WITH DISCREPANCIES. <br />5. CONTRACTOR TO PREPARE SIDEWALK SUBGRADE PER CITY OF LOUISVILLE <br />DESIGN AND CONSTRUCTION STANDARDS SECTION 508 WITH INSPECTION <br />PROVIDED BY OWNER/ CONSTRUCTION PROJECT MANAGER. <br />6. EXTERIOR LIGHTING WILL HAVE OCCUPANCY SENSOR CONTROL WITH <br />MANUAL OVERRIDE. LIGHTS WILL ONLY BE ON WHEN OCCUPANTS ARE <br />USING THE SPACE FOR SANCTIONED EVENTS. <br />7. ALL PRIVATE INSPECTION SHALL BE COORDINATED WITH THE <br />OWNER/PROJECT MANAGER. NO CITY INSPECTIONS ARE REQUIRED. <br />t <br />MAR 2015 CMD <br />Nor <br />2% SLOPE TO BACK OF CURB <br />ATTACHED OR DETACHED WALK <br />• 4' OR 5' WIDE WALKS SHALL BE 4" THICK <br />• 8' WIDE WALKS SHALL BE 6' THICK <br />• ALL WALKS AT RESIDENTIAL DRIVEWAYS <br />SHALL BE 6" WITH FIBERMESH <br />MIN.* <br />" R <br />• 1/4"D. IF TEMPLATES ARE NOT USED <br />CONTRACTION OR <br />WEAKENED PLANE JOINT <br />2' <br />2' - 1" <br />REVISIONS LECityof <br />DATE BY Louisville <br />COLORADO - SINCE 1882 <br />i"PREFORMED <br />JOINT MATERIAL <br />EXPANSION JOINT <br />4' <br />SLOPE =" : 1' <br />3'_11" <br />CURBWALK <br />DEPARTMENT OF PUBLIC WORKS <br />CURBWALK & WALK <br />GASTANDARDS DETAILSIDETAILS%S1REETl'S7 CURBWALK WALK.DWG <br />6" <br />1 <br />DRAWN BY: ML JAN 94 <br />APPROVED BY: CMD MAR 15 <br />SHEET <br />57 OF 74 <br />CO <br />m <br />-J <br />W <br />z <br />U <br />z <br />OWNER: <br />STEELWAVE <br />101 CALIFORNIA <br />STREET <br />SUITE 800 <br />SAN FRANCISCO, CA <br />94111 <br />303.327.9729 <br />I 'I ;1 I IMI1.Ji11 : <br />FOR REVIEW ONLY <br />NOT FOR <br />CONSTRUCTION <br />IQmley*HOrn <br />Kimley-Horn and Associates, Inc. <br />DATE: <br />0/29/2022 PUD AMEND <br />SHEET TITLE: <br />PHASE 1 SITE & <br />GRADING PLAN <br />3 0F7 <br />