Laserfiche WebLink
4 <br />MOTHERLODE BUILDING AT 602 SOUTH TAYLOR AVENUE FINAL PLANNED UNIT DEVELOPMENT <br />LOT 7, BLOCK 4, COLORADO TECHNOLOGICAL CENTER FIRST FILING <br />SECTION 16, TOWNSHIP 1 SOUTH, RANGE 69 WEST OF THE 6th P.M. <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO <br />OWNERSHIP SIGNATURE BLOCK: <br />BY SIGNING THIS PUD, DEEPIKA AVANTI ACKNOWLEDGES AND ACCEPTS ALL THE REQUIREMENTS AND INTENT SET <br />FORTH IN THIS PUD, <br />WITSS MY f OUAN L(S) THHII,/— / Nri'l DAY OF ( 11 , 20 2--2 <br />(?IKA ANANTI <br />7 Q L44r4ig% YYIP t- (NOTARY SEAL) <br />NOTARY NAME <br />SIGNATURE <br />MY COMMISSION EXPIRES _10 /2 2 t-f <br />CITY COUNCL CERTIFICATE: <br />APPROVED THIS ! 2.. <br />44•— <br />DAY OF <br />BY THE CITY COUNCIL OF THE CITY OF LOUISVILLE, COLO <br />RESOLUTION NO. 2- <br />YESENIA IIIIENDEZ VAZQUEZ <br />NOTARY PUBLIC <br />STATE OF COLORADO <br />NOTARY ID 20204031702 <br />MY COMMISSION EXPIRES 0O1i1/2024 <br />,201-1._ <br />PLANNING COMMIUJON CERTIFICATE: <br />APPROVED THIS 2 3 F1 DAY OF ___1-1-1.3 rite . , 20 2-7-- <br />BY THE PLANNING COMMISSION OF THE CITY OF LOUISVILLE, COLORADO. <br />RESOLUTION NO. / 0 <br />SERIES O� <br />Cherry St. <br />AVista <br />Hospital <br />Campus <br />Superior <br />Louisville <br />Lafayette <br />VICINITY nAP !► <br />NO SCALE <br />NORTH <br />ce <br />PROJECT DESCRIPTION: <br />NEW 17,597 SF MOTHERLODE BUILDING ON VACANT LAND TO BE PRIVATELY OWNED AND <br />RENTED TO ENTREPRENEURS/TENANTS NEEDING UP TO 17,597 SF TO DO LIGHT <br />INDUSTRIAL MANUFACTURING, RESEARCH AND DEVELOPMENT IN THE COMMERCIAL <br />STRUCTURE. EXCESS PARKING IS PROVIDED FOR ENTREPRENEURS/TENANTS SUBMITTING <br />FOR OFFICE SPACE PERMITTING. <br />WAIVER REQUESTS: <br />1. WAIVER IS REQUESTED FOR: IDDSG 2.1.1F <br />DRIVEWAYS SERVING BUILDING SITES ON EITHER SIDE OF A PUBLIC STREET SHALL EITHER <br />BE ALIGNED OR OFFSET TO PROVIDE A MINIMUM SEPARATION OF 75-FEET WHEN NOT <br />LOCATED ADJACENT TO A PUBLIC STREET INTERSECTION. (S) <br />THE SITE DRIVEWAY LOCATION COMPLIES WITH IDDSG 2.1.16 FOR SAME SIDE OF STREET <br />DRIVEWAY SEPARATIONS. A VARIANCE IS REQUESTED FOR IDDSG 2.1.1 F AS THE EXISTING <br />ACROSS STREET DRIVEWAYS WERE NOT INSTALLED IN COMPLIANCE WITH SECTION 2.1.10_ <br />THE SITE HAS LIMITED FRONTAGE, ALIGNING TO THE ACROSS STREET DRIVEWAY #2 (SEE <br />SITE PLAN), WOULD RESULT IN NON- COMPLIANCE WITH IDDSG 2.1.1 G FOR ACROSS <br />STREET DRIVEWAY #3. GIVEN THE SMALL SITE FRONTAGE, OUR DRIVEWAY LOCATION IS <br />DIFFICULT TO MOVE LOCATIONS DUE TO BUILDING SIZE, FRONTAGE LENGTH AND <br />DETENTION POND FOOTPRINT REQUIRED. <br />2. WAIVER IS REQUESTED FOR IDDSG 5.2.A.1 <br />THE LANDSCAPE BUFFER SHALL BE 10' WIDE ON THE NORTH SIDE. <br />A 10.3-FOOT WIDE BUFFER FROM NORTH PROPERTY UNE TO BUIDLING IS PROVIDED <br />INCLUDING A 5-FOOT WIDE SIDEWALK AND 5.3-FEET OF ENHANCED LANDSCAPE AND <br />SCREENING. PLANTINGS WITHIN THE 5.3-FOOT WIDE AREA ARE NEARLY DOUBLE THE <br />QUANTITY OF TREES, SHRUBS AND GROUND COVER REQUIRED BY CODE TO ACHIEVE THE <br />FUNCTIONAL APPEARANCE OF A 10-FOOT WIDE BUFFER TO ACCOMMODATE THE 5 FOOT <br />WIDE SIDEWALK ALONG THE NORTH SIDE OF THE BUILDING CONNECTING TO SOUTH <br />TAYLOR AVENUE. <br />GENERAL NOTES: <br />1. THE CITY OF LOUISVILLE IS NOT RESPONSIBLE FOR DAMAGE TO OR REPAIR OF MONUMENT <br />SIGNS, PAVEMENT SURFACES, OR LANDSCAPING CAUSED DURING REPAIR OR MAINTENANCE <br />OF UTILITIES LOCATED WITHIN PUBLIC UTILITY EASEMENTS. <br />2. ESTIMATED COMPLETION OF THE PROJECT SUMMER 2023. <br />3. THE PROJECT IS TO BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH CRITERIA SET <br />FORTH IN THE COLORADO TECHNOLOGICAL CENTER GENERAL DEVELOPMENT DESIGN <br />STANDARDS AND GUIDELINES_ <br />4. ROOFTOP MECHANICAL UNITS WILL BE LOCATED 20FT BACK FROM THE EDGE OF THE ROOF OR <br />SCREENED BY THE BUILDING PARAPET. <br />5_ THE SOUTHERNMOST END OF THE FIRE ACCESS LANE SHALL NOT BE USED FOR SNOW <br />STORAGE. <br />6. CONCRETE WALKS, CURB AND GUTTER THAT ARE DAMAGED ADJACENT TO THE SITE SHALL BE <br />REPLACED BY THE DEVELOPER. <br />03976929 08/16/2022 09:03 AM <br />. RF: $103.00 DF: $0.00 Page: 1 of 10 <br />Electronically recorded in Boulder County Colorado. Recorded as received. <br />PROJECT DATA <br />OWNER: <br />Deepika Avanii <br />698 Dixon Rd <br />Boulder, CO <br />(303) 440-4431 <br />deepIka aholistictherapiesinc.com <br />OWNER'S REPRESENTATIVES: <br />Charles Ogsbury <br />(720) 480-2066 <br />chuckagsbury0 gmail.com <br />Zen Ogsbury <br />(303) 817-3483 <br />zenogsbury gmail.com <br />CIVIL ENGINEER: <br />Creative Civil Solutions <br />723 Main St, Unit 2 <br />Longmont CO, 80501 <br />(303) 684-8484 <br />curtisk G creativecivil_com <br />ARCHITECT: <br />Kenny Davis Architects <br />1 63B S Brentwood St <br />Lakewood CO, 80232 <br />(303) 960-5813 <br />kenny Okennydavisarchitects.com <br />LANDSCAPE ARCHITECT: <br />Outside LA <br />Boulder CO <br />(303)718-6472 <br />osla me.com <br />ELECTRICAL ENGINEER: <br />LW Engineering, LLC <br />Illumination Engineering <br />2470 S Lafayette St <br />Denver CO, 80210 <br />(303) 733-5990 <br />ZONING: <br />Planned Community Zone District - Industrial PUD (Colorado Tech Center PUD) <br />APPROVED CODES: <br />Louisville Municipal Code <br />Commercial Development Design Standards and Guidelines <br />City of Louisville <br />Industrial Development Design Standards & Guidelines (IDDSG) <br />SHEET INDEX SITE DATA <br />SHEET 1 of 10 <br />SHEET 2 of 10 <br />SHEET3of 10 <br />SHEET 4 o1 10 <br />SHEET of 10 <br />SHEET 6 of 10 <br />SHEET 7 of 10 <br />SHEET8o110 <br />SHEET9of 10 <br />SHEET 100110 <br />- COVER SHEET <br />- PUD DEVELOPMENT PLAN <br />- MASTER UTILITY & GRADING <br />PLAN <br />- SITE DETAILS <br />- ELEVATIONS <br />- LANDSCAPE PLAN <br />- LANDSCAPE NOTES & DETAILS <br />- PHOTOMETRIC SITE PLAN <br />- PHOTOMETRIC SCHEDULES & <br />SPECIFICATIONS <br />- PHOTOMETRIC SCHEDULES & <br />SPECIFICATIONS <br />SITE AREAS <br />TOTAL SITE AREA <br />BUILDING COVERAGE <br />LANDSCAPE AREA <br />HARDSCAPE AREA <br />TOTAL <br />BUILDING HEIGHT <br />MINIMUM HEIGHT <br />MAXIMUM HEIGHT <br />LOW GRADE 0 BLDG <br />HIGH GRADE 0 BLDG <br />AVERAGE GRADE <br />AVERAGE BLDG HT <br />TOP OF MECH SCREEN <br />REQUIRED <br />NA <br />NA <br />25% MIN <br />75% MAX <br />NA <br />NA <br />NA <br />NA <br />NA <br />35'-0" <br />NA <br />EXISTING <br />52,372 SF <br />NA <br />NA <br />NA <br />NA <br />NA <br />NA <br />NA <br />NA <br />NA <br />NA <br />PROPOSED <br />52,372 SF <br />17,597 SF (33.6%) <br />13,171 SF(25.1%) <br />39,201 SF (74.9%) <br />57,372 Sf (100%) <br />20'-IY' <br />30'-0' <br />5326.06' <br />5327.60 <br />5326.89 <br />26'-8" <br />NA' <br />* NO SCREENING PROPOSED, ROOFTOP EQUIP WILL BE SET BACK 20'-0" MIN <br />BUILDING AREAS <br />MAIN LEVEL <br />MEZZANINE LEVEL <br />TOTAL <br />SETBACKS - BUILDING <br />WEST (FRONT) 30'-0' NA 30. <br />EAST (REAR) 15'-0" NA <br />NORTH (SIDE) 10'-0' NA <br />SOUTH (SIDE) 10'-0' NA <br />SETBACKS -PARKING <br />WEST (FRONT) <br />EAST (REAR) Cr-0" <br />NORTH (SIDE) 10'-0' <br />SOUTH (SIDE) 10'-0" <br />LANDSCAPE SIDEYARD BUFFER <br />NORTH (SIDE) 10'-0' NA 5.30' <br />SOUTH (SIDE) 10'-0' NA 10.00' <br />PARKING SPACES* <br />STANDARD <br />EV CHRG W CONDUIT <br />EV CHRG W WIRED <br />EV CHRG W STATION <br />EV ACCESSIBLE <br />ACCESSIBLE (VAN) <br />TOTAL <br />' PARKING CALCULATIONS <br />NA <br />NA <br />REQUIRED <br />33 <br />5 <br />4 <br />3 <br />1 <br />2 <br />33 <br />NA <br />NA <br />NA <br />NA <br />NA <br />NA <br />MFG / RESEARCH & DEVELOPMENT 18,269sf 2/1000SF = 33 SPACES <br />COVERED LOADING 1.328sf 0 SPACES <br />BUILDING FOOTPRINT 17,597sf <br />33 PARKING REQUIRED <br />ACCESSIBLE PARKING SPACES PER IBC 2018 TABLE 1106.1 <br />HC REQUIRED: 2 (VAN ACCESSIBLE) <br />SURFACE PROVIDED=38 (INCL 2 IG VAN) <br />5 EXCESS STALLS FOR OFFICE FINISHES <br />2 STANDARD LOADING/ I SEMI LOADING <br />TOTAL PROVIDED 38 STALLS <br />16,269 GSF <br />0 GSF <br />16,269 GSF <br />15.18' <br />10.30' <br />106.38' <br />48.62' <br />2.00' <br />100.83' <br />10.00' <br />PROPOSED <br />38 <br />5 <br />4 <br />4 <br />1 <br />2 <br />38 <br />Kenny Davis Architects <br />1630 Sorb efentieood St <br />Lakewood. Gokaieb, 00232 <br />Tat 30S.980-5613 <br />ggi <br />CREATIVE <br />CIVIL SOLLMON <br />723 Main Street, Unit 2 <br />Longmont, Colorado 80501 <br />303.684.84434 <br />outside la <br />landscape arclwtecture+ <br />urban design + <br />planning <br />boulder 1lteamt oat apexes, o0 <br />p. 303.517.92E6 <br />I. 970.367.6160 <br />oslaame com <br />vV <br />LW BogisaerLg, LLC <br />ID®inatioln Bnginaari <br />247V S. Lakivtle St. <br />Deaver. CO 80210 <br />Matherlode <br />Bldg <br />Block 4 Lot 7 <br />COLORADO <br />TECHNOLOGICAL <br />CENTER, FIRST FILING <br />602 S. Taylor Ave <br />Louisville, CO 80027 <br />PROJ NO: <br />DATE <br />REV <br />REV <br />17005 <br />Jan 23, 2022 <br />PUD 1-01.23.22 <br />PUD 2 - 02.01.22 <br />PUD 2R1 - 03.1522 <br />PUD 3 - 0421_22 <br />PUD 4 - 05.1622 <br />COVER SHEET <br />1 <br />SHEET 1 OF 1 0 <br />