Boulder County, CO <br />03976929 <br />4 of 10 <br />ADHERE CAP TO TOP BLOCK <br />W/ CONCRETE ADHESIVE <br />PER MFR RECOMMENDATIONS <br />BASALITE MESA <br />MEDIUM UNIT SIZE <br />8x18x11 OR APPROVED EQ <br />ASSEMBLE WALL W/ GEOGRID & <br />PINS PER MFR SPECIFICATIONS (TYP) <br />12" DEPTH 1" WASHED CRUSHED <br />FREE DRAINING GRAVEL <br />COOT CLASS A AGGREGATE PER SPECS <br />AGGREGATE BACKFLL <br />NEW LANDSCAPE <br />-TI—II <br />CONCRETE BASE <br />PAD 8" THICK MIN <br />WI 2 CONT REBAR <br />IIlllllli ' <br />8° SCARIFY & RECOMPACT <br />BELOW GRAVEL TO 95% SPD <br />PER RETAINING WALL SPECS <br />F <br />N <br />1. INSTALLER TO COMPLY WITH MIN GEOGRID TYPE, LENGTH AND SPACING PER THIS DETAIL <br />INSTALLER SHALL COORDINATE FINAL DESIGN WITH WALL MANUFACTURER BASED ON THESE MIN SPECS <br />MANUFACTURER SHALL ADD ADDITIONAL GRID OR LENGTH AS NEEDED AND PE STAMP PRIOR TO INSTALLATION. <br />2. INSTALLER SHALL VERIFY SOIL CONDITIONS WITHIN BACKFILL ZONES ONSITE ARE SUITABLE <br />BASED ON MANUFACTURERS DESIGN PROVIDED <br />3. RETAINING WALL BLOCKS TO BE BASAUTE MESA MEDIUM UNIT OR APPROVED <br />EQUAL OWNER SPECIFIED COLOR: MEDIUM BROWN # 386, INSTALL PER MFR SPECS <br />4. GRADE AT BOTTOM OF WALL TO 2% MINIMUM SLOPE AWAY FROM WALL <br />5. INSTALLER SHALL NOTIFY ENGNEER IMMEDIATELY IF ANY FIELD CONDITIONS DO NOT MEET <br />MANUFACTURER'S DESIGN PARAMETERS OR IF FIELD CONDITIONS WARRANT DESIGN MODIFICATIONS <br />6. FINAL DESIGN SHALL BE SUBMITTED TO ENGINER OF RECORD PRIOR TO INSTALLATION <br />GRADE 10% MAX <br />-. <br />MIRAFI S1200 FILTER FAFBRIC - _ - _ 1 <br />x; BETWEEN GRAVEL & CLASS 1 - . — <br />Y' BACKFILL & SOIL LAYERS <br />2nd Layer <br />8" TOPSOIL <br />AMEND PER LANDSCAPE <br />REINFORCED BACKFILL (CLASS 1 <br />STRUCTURAL BACKFILL) <br />COMPACTED 95% OF MAXIMUM <br />STANDARD PROCTOR DENSITY <br />8MAX LIFTS (ASTM D698) <br />GEOGRID REINFORCEMENT TYP <br />(SEE SCHEDULE) <br />GEOGRID SPEC: MIRAFI MIRAGRID 3XT <br />OR APPROVED EQ, MUST EXTEND <br />m=i Ili GRID TO FACE OF WALL <br />_ 95% COMPACTED SOIL <br />111.1t i La II 1I—I I j a SLOPE 0 5% TO FINISHED GRADE <br />0 FACE OF WALL <br />FOR SUB -SURFACE DRAINAGE <br />GEOGRID REINFORCEMENT SCHEDULE <br />LENGTH BEHIND «ACK OF WALL» <br />LENGTH TOP OF Ewa( <br />5.OFT 1 <br />4.0FT 4 <br />4.OFT* 6 <br />J�l-f =1 I 1=1 I I-III-III-i <br />4' DIA SDR35 SOCK WRAPPED PERF <br />DRAIN PIPE; OUTLET 0 ENDS OF WALL <br />& 0 40' CENTERS MAX. <br />SLOPE TO DRAIN (1/8"/FL) <br />ANGLE CMU RETAINING Willi 10' . 4 H < 5' <br />x <br />x <br />>` PLAN VIE <br />rPARAPET CAP <br />III <br />11 <br />11 <br />11 <br />CMU 2 <br />I I 1 1 <br />1 1 1 111 1 1 emu1 <br />I I 1 I <br />1 I 1 I I <br />I I 1 1 <br />1 I I I I <br />LEFT ELEVA1ION <br />1 <br />I 1 I <br />11 <br />I 1 I <br />I I <br />11 <br />1 <br />I I <br />III <br />r_- <br />d,_n.l <br />.I /fir-n° <br />FRONT ELEVA1ION <br />1 <br />1[ 1 I I 1 1 <br />I I I 1 I I 1 <br />1 1 1 1 1 1 1 <br />1111111 1111111 <br />1 1 1 1 1 1 1 1[ 1 1 <br />SIR ELEVATION <br />LAYER 1 <br />LAYER 2: <br />LAYER 3: <br />ricsi <br />(LAYER 3 REQURIED 'MEN WALL HEIGHT EXCEEDS 48' FROM FG) 11* <br />• <br />i <br />x <br />x <br />2' SCHED. 40 PIPE RAIL <br />TYP OF ALL MEMBERS. <br />COLOR: SILVER <br />EPDXY PAINT <br />3' X 1/8' STL PLATE <br />TOE BOARD. <br />SLOPE CONC TO DRAIN <br />AWAY FROM PIPE <br />• <br />I' I <br />—6'-,I` <br />GAURDRAIL 5EC11ON <br />METAL DOOR <br />PAINTED MATERIAL 'AM PT" <br />MATCHING IBLDG PARAPET <br />PARAPET CAP <br />CMU2 <br />CMu1 <br />rPARAPET CAP <br />CMU 2 <br />CMU 1 <br />,a- <br />URE PLAN AND ELEVATIONS <br />11 <br />111 1 <br />1 <br />1 1 l 1 1 <br />1 1 1 1 1 1 1 <br />RIGHT ELEVAPQN <br />rPARAPET CAP <br />CMU2 <br />CMU1 <br />ADHERE CAP TO TOP BLOCK <br />W/ CONCRETE ADHESIVE <br />PER MFR RECOMMENDATIONS <br />BASALITE MESA <br />MEDIUM UNIT SIZE <br />8x18x11 OR APPROVED EQ <br />ASSEMBLE WALL W/ GEOGRID & <br />PINS PER MFR SPECIFICATIONS (TYP) <br />12" DEPTH 1" WASHED CRUSHED <br />FREE DRAINING GRAVEL <br />COOT CLASS A AGGREGATE PER SPECS <br />AGGREGATE BACKFILL <br />NEW LANDSCAPE <br />CONCRETE BASE <br />PAD 8' THICK MIN <br />W/ 2 CONT REBAR <br />8" SCARIFY & RECOMPACT <br />BELOW GRAVEL TO 95% SPD <br />PER RETAINING WALL SPECS <br />•1I11111I' <br />2'—# <br />GRADE 10% MAX <br />2nd Layer <br />8" TOPSOIL <br />AMEND PER LANDSCAPE <br />REINFORCED BACKFILL (CLASS 1 <br />STRUCTURAL BACKFILL) <br />COMPACTED 95% OF MAXIMUM <br />STANDARD PROCTOR DENSITY <br />8" MAX LIFTS (AS1M D698) <br />GEOGRID REINFORCEMENT TYP <br />I (SEE SCHEDULE) <br />MIRAFI S1200 FILTER FAFBRIC `_ - <br />BETWEEN GRAVEL & CLASS 1 - - - r GEOGRID SPEC: MIRAFI MIRAGRID 3XT <br />BACKFILL & SOIL LAYERS _ - - : _ - OR APPROVED EO, MUST EXTEND <br />GRID TO FACE OF WALL <br />I I-1111 I 95% COMPACTED SOIL <br />III iI-111=1_I I- SLOPE 0 5% TO FINISHED GRADE <br />0 FACE OF WALL <br />FOR SUB -SURFACE DRAINAGE <br />GEOGRID REINFORCEMENT SCHEDULE <br />LENGTH BEHIND <<BACI( OF WALL» <br />ILE/ LTH TOP OF BLOCK <br />LAYER 1: 5.OFT 1 <br />LAYER 2: 4.0FF 4 <br />irr 'Or <br />4" DIA SDR35 SOCK WRAPPED PERF <br />DRAIN PIPE; OUTLET 0 ENDS OF WALL <br />& 0 40' CENTERS MAX. <br />SLOPE TO DRAIN (1/8"/FT.) <br />EEL <br />1. INSTALLER TO COMPLY WITH MIN GEOGRID TYPE, LENGTH AND SPACING PER THIS DETAIL <br />INSTALLER SHALL COORDINATE FINAL DESIGN WITH WALL MANUFACTURER BASED ON THESE MIN SPECS <br />MANUFACTURER SHALL, ADD ADDITIONAL GRID OR LENGTH AS NEEDED ACID ef 1TAMP PRIOR TO INSTALLATION. <br />2. INSTALLER SHALL VERIFY SOIL CONDITIONS WITHIN BACKFILL ZONES ONSITE ARE SUITABLE <br />BASED ON MANUFACTURERS DESIGN PROVIDED <br />3. RETAINING WALL BLOCKS TO BE BASALITE MESA MEDIUM UNIT OR APPROVED <br />EQUAL OWNER SPECIFIED COLOR: MEDIUM BROWN # 386, INSTALL PER MFR SPECS <br />4. GRADE AT BOTTOM OF WALL TO 2% MINIMUM SLOPE AWAY FROM WALL <br />5. INSTALLER SHALL NOTIFY ENGINEER IMMEDIATELY IF ANY FIELD CONDITIONS DO NOT MEET <br />MANUFACTURER'S DESIGN PARAMETERS OR IF FIELD CONDITIONS WARRANT DESIGN MODIFICATIONS <br />6. FINAL DESIGN SHALL BE SUBMITTED TO ENGINER OF RECORD PRIOR TO INSTALLATION <br />MiGLE CMU RETAINING WALL H c 212 <br />EXTEND SIGN POST VERT TO <br />HEIGHT PER CODE <br />r- 2'x2' GALVANIZED TUBE <br />\ re <br />CONC SLOPE TOP <br />WHITE REFLECTING TAPE <br />6°0 SCH 40 STL PIPE <br />FILL W/ CONC <br />2" CROWN <br />ASPHALT PVMT <br />CONC ENCASEMENT <br />LJ <br />SOLID SLEEVE EXTEND <br />6' ABOVE CONC, DRILL SINGLE <br />BOLT HOLE TO SECURE UPPLER SIGN POST <br />SOLID SLEEVE FOR SIGN POST <br />GALV STL (TYP) <br />„ <br />ivj . ,4a <br />% //‹ <br />1'-6" <br />CONC PVMr <br />• <br />• <br />• <br />I <br />Kenny Davis Architects <br />1E0a South ri°ntwond St <br />Lakewood. Colorado, 80232 <br />Tat ao34 —58I3 <br />CREATIVE <br />CIVIL SOLUTION <br />723 Main Street, Unit 2 <br />Longmont, Colorado 80501 <br />303.684.8484 <br />outside la <br />landscape architecture t <br />urban design + <br />planning <br />boulder I etas mbost wino, Co <br />p. 303.517.9256 <br />f. 970.367.51B0 <br />nOrrame.nom <br />LW eat, LLC <br />2470 S. La iyetSe St <br />Denver, OD B021130 <br />P:303-7/3-6472 <br />Motherlode <br />Bldg <br />Block 4 Lot 7 <br />COLORADO <br />TECHNOLOGICAL <br />CENTER, FIRST FILING <br />602 S. Taylor Ave <br />Louisville, CO 80027 <br />PROJ NO: 17005 <br />DATE Jan 23, 2022 <br />REV PUD 1 - 01.23.22 <br />REV PUD 2 - 02.01.22 <br />PUD 2R1 - 03.15.22 <br />PUD 3 -04.21.22 <br />PUD 4 - 05.16.22 <br />SITE DETAILS <br />4 <br />SHEET OF 10 <br />