Laserfiche WebLink
GLAZING <br />BEYOND <br />\T 0 PARAPFT WAI I <br />AWNING <br />, T.0 GARAGE SLAB <br />\ T_O TOWFR RFYOND <br />O <br />N <br />T.0 PARAPET WALL <br />HOLLOW METAL <br />DOOR AND <br />FRAME <br />EXISTING STL. FRAMED <br />AWNING <br />EXISTING STOREFRONT <br />GLAZING <br />EXISTING EXIT DOOR _ <br />EXISTING 48" CMU <br />RETAINING WALL <br />UPPER LEVEL FLOOR <br />,` .` T C1 nRIVF/C,ARAC;F SI AR <br />PROPERTY LINE <br />I <br />SOUTH ELEVATION <br />1/8"=1'-0" (EAST BUILDING) <br />1111111II1111l1ll <br />LJ0412I I. • <br />11 <br />)111111I11111)IIIIIIIIIIIIIIITIIIIIIIIIIIIIIlI1lUllll <br />EXISTING 1 1/2" CAP <br />ON CMU RETAINING <br />WALL <br />CMU-4 SPLIT FACED BLOCK— <br />T.O. PARAPET WALL <br />STEEL <br />AWNING <br />DOWN LIGHTING ---__ <br />CMU-4 SPLIT <br />FACE BLOCK <br />CMU-1 SPLIT <br />FACE BLOCK <br />T_O GARAGF S <br />CORRUGATED <br />METAL PANEL <br />CMU-2 GROUND FACE BLOCK <br />(4" RUNNING BOND) <br />r <br />NORTH ELEVATION <br />1/8"=1'-0" (EAST BUILDING) <br />EXISTING 4" METAL CAP ON EFIS WALLS <br />EXISTING EFIS EXTERIOR FINISH <br />— TYPICAL <br />EXISTING SCREEN WALL: <br />(PRIVACY/SECURITY WALL ON <br />PROPERTY LINE) <br />EXISTING 1 1/2" CMU CAP <br />,' © TOP OF WALL <br />EXISTING CMU-3 GROUND FACE <br />BLOCK <br />EXISTING WIRE MESH OVER EFIS <br />CMU-4, SPLIT FACED <br />BLOCK <br />CORRUGATED METAL <br />PANEL <br />EAST ELEVATION <br />1/8"=1'-0" (EAST BUILDING) <br />EXISTING TOP COURSE BANDING <br />CMU-4 SPLIT FACE <br />T.0 RAISED <br />SCREEN WALL <br />0 <br />rag <br />EXISTING WALL BEYOND <br />CMU-5 <br />CMU-6 <br />eVYl.�.i�v� <br />I— <br />IiliIIiliIIIIIIIIII lilt IIIki, u1EIIINilill111JIIl !Ill 1H11111111111ill111111111111iillllil111111IIIIIIIl1111(i111111 1illl illIH lilli ll,llNI 1 <br />EXISTING <br />RETAINING <br />WALL <br />EXISTING GRADE <br />L-_ <br />T.0 DIV.E/_GA AGE.SLAB I <br />(WEST BUILDING) <br />BUILDING ELEVATION NOTES <br />1. All roof mounted HVAC units shall be fully screened in accordance with the <br />Commercial <br />Development Design Standards and Guidelines (CDDSG). <br />2. All on site trash dumpsters visible from an adjoining public right —of --way <br />shall be fully screened in accordance with the CDDSG. <br />FINISH LEGEND <br />A EXISTING ELEVATION <br />0 <br />Ui <br />ZU <br />z ,j T.0 SLAB TO ALIGN WITH, <br />EXISTING V.I.F <br />EFIS <br />CMU SCREEN WALL <br />BEYOND <br />48" HIGH CMU WALL C�? <br />PROPERTY LINE <br />— UEPER__LE YEL_F!. Q4g - <br />0 <br />O rONCRFTF SI AR ` .` <br />AT GARAGE INTERIOR <br />EXISTING GRADE <br />T.0 PARAPET WALL—MATG`I. <br />0 <br />0 <br />CMU-1 SPLIT FACE BLOCK ROBINSON BLOCK "DESERT YELLOW" <br />CMU-2 <br />CMU-3 <br />CMU-4 <br />CMU-5 <br />CMU-6 <br />GROUND FACE ROBINSON BLOCK "DESERT YELLOW" <br />GROUND FACE ROBINSON BLOCK "MAROON" <br />SPLIT FACE ROBINSON BLOCK "MAROON" <br />SPLIT FACE ROBINSON BLOCK "IVORY" <br />(TO MATCH EXISTING) <br />SPLIT FACE— REGULAR FLUTED 8 POST, <br />ROBINSON BLOCK "IVORY" (TO MATCH EXISTING) <br />CORRUGATED STEEL GALVANIZED FINISH <br />0 0 0 0 0 0 0 <br />DULANEY <br />architecture <br />5825 E. Maplewood Avenue <br />Centennial, Colorado 80111 <br />PH: (303) 615-9123 <br />web: dulaneyarchitecture.com <br />NOTE TO CONTRACTORS: <br />No work shall be performed <br />until all plans are approved <br />by the local jurisdiction. <br />The architect & engineers <br />shall not be responsible <br />for any work performed <br />prior to the issuance of <br />permits. <br />REVISION DATE' <br />MARK DATE 'DESCRIPTION <br />A05.20.22 B06. COMMENTS #1 <br />06.2q.22 BLDG. COMMENTS #2 <br />PROJECT TITLE <br />N <br />0 <br />0 <br />CZ ckZ <br />v0 <br />zv <br />0a <br />} <br />Ln <br />JOB NO.. 2021-86 <br />DRAWN BY' BM <br />CHECKED BY' DPD <br />ISSUED DATE' 03.18.22 <br />SHEET TITLE <br />BUILDING <br />ELEVATIONS <br />SHEET NUMBER <br />EFIS EXTERIOR FINISH AND INSULATION SYSTEM <br />PUD AMENDMENT <br />LOT 1 AND 2, CRYSTAL ESTATES, COUNTY OF BOULDER, STATE OF COLORADO <br />5 <br />