My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ordinance 2022-1845
PORTAL
>
CITY COUNCIL RECORDS
>
ORDINANCES (45.120)
>
2022 Ordinances
>
Ordinance 2022-1845
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/16/2024 1:18:34 PM
Creation date
1/13/2023 12:31:35 PM
Metadata
Fields
Template:
City Council Records
Also Known As (aka)
IECC 2021__Municipal Code Chapter 15.18.030__Amendments and Deletions to Include Requirements for Commerical Energy Use Intensity Performance Targets and Restrictions
Meeting Date
12/20/2022
Doc Type
Ordinance
Signed Date
12/20/2022
Ord/Res - Year
2022
Ord/Res - Number
1845
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
APPENDIX PT <br />MODELING TO A PERFORMANCE TARGET <br />PT101 Scope. This section establishes criteria for demonstrating compliance with <br />a performance target, and is required for new multifamily. (�pancy R-2), <br />offices greater than 5,000 ft2, primary and secondary schools, parking_ garages, <br />and warehouses. All end use load components within and associated with the <br />building and their building sites shall be modeled. <br />PT102 Mandatory requirements. The requirements in this section are <br />mandatory requirements and shall be required in addition to the provisions of <br />ASHRAE 90.1 Appendix G. <br />PT103 Performance target. Projects of the types listed in Table PT103 shall <br />demonstrate that the proposed design reaches a fixed energy use intensity (( I) <br />less than or equal to the values in Table PT103, calculated utilizing the energy <br />modeling procedures of Appendix G of ASHRAE 90.1. For building <br />multiple occupancy types, the modeled performance target shall be a weighted <br />average of the floor area of each occupancy_ type. <br />Exception: Energy used for electric vehicle charging, data centers, and <br />process loads shall be excluded from compliance modeling_ <br />TABLE PT103 <br />PERFORMANCE TARGETS <br />BUILDING TYPE <br />PERFORMANCE <br />TARGET <br />(kBTU/ft2) <br />Multifamily (Occupancy R-2) <br />32 <br />Office, small (>5,000 ft2) <br />19 <br />Office, medium (5,000 — 50,000 ft2) <br />23 <br />Office, large (>50,000 ft2) <br />28 <br />School, primary <br />34 <br />School, secondary <br />31 <br />Warehouse <br />11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.