Laserfiche WebLink
Boulder County, GO <br />03995274 <br />9 of 14 <br />• <br />C:1Users\cljdwel112tocumentsl0202.50 Water Mill CW CENTRAL cltidwrell.rvt <br />10/2112021 2:05:01 PM <br />LOT 3, ST. LOUIS PARISH AND BOLDER INNOVATION CAMPUS - FILING NO.1 <br />H.C. PARKING <br />SIGN <br />CONCRETE <br />WHEEL STOP <br />4" WIDE WHITE <br />PAINTED <br />STRIPE. TYPICAL <br />UNIVERSAL H.C. <br />SYMBOL. PAINT <br />WITH 4" WIDE <br />STRIPING <br />4" WIDE WHITE <br />PAINTED CROSS <br />STRIPESe-�AT 24" <br />V.V. <br />I I <br />1 81-°. 1 <br />DTL-HC Parklna Stall - Wide PLAN <br />11B" = 1'-0" <br />VERTICAL REINFORCING <br />PER STRUCTURAL <br />DRAWINGS <br />GROUT CELLS SOLID <br />UTL-CMU Trash Enclosure Gate at CMU PLAN <br />1 112" = 1'-0" <br />i <br />1 <br />9'-0" <br />FINAL PLANNED UNIT DEVELOPMENT AND SPECIAL REVIEW USE <br />A SUBDIVISION LOCATED IN <br />A PORTION OF THE SOUTHWEST QUARTER OF SECTION 16, TOWNSHIP 1 SOUTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO <br />Jr_ <br />WELD HINGE TO <br />POST AND GATE <br />GATE ASSEMBLY AS <br />IDENTIFIED <br />EMBED STEEL POST IN <br />CONCRETE FOUNDATION <br />2' DEPTH MIN. <br />RED BORDER ON WHITE I <br />12" <br />RED CROSS - <br />SIGN OUT SYMBOL <br />BLACK P <br />REFLECTORIZED SIGN <br />CONSTRUCTED OF <br />PORCELAIN STEEL WITH <br />BEADED TEXT OR <br />EQUAL <br />2" SQUARE GALVANIZE <br />STL. POST <br />2 114" SQUARE <br />GALVANIZED STL. <br />ANCHOR POST <br />12" DIA. CONCRETE <br />FOOTING FOR ALL SIGN <br />POSTS <br />ifl <br />FIRE <br />LANE RED DIRECTIONAL <br />ARROW <br />0 <br />O <br />O <br />RED TEXT <br />RED TOW AWAY <br />SIGN <br />a FINISH GRADE <br />9 9- <br />COMPACTED SOIL <br />4 <br />FIRE <br />LANE <br />NO PARKING <br />LEFT SIDE <br />FIRE <br />LANE <br />NO PARKING <br />BOTH S1DES <br />FIRE <br />LANE <br />NO PARKING <br />RIGHT SIDE <br />1. SIGNS SHALL BE LOCATED AT THE RIGHT SIDE OF THE FIRE LANE ENTRANCE AND AT THE <br />END OF THE FIRE LANE• THE INTERMEDIATE SIGNS SHALL HAVE DOUBLE HEADED ARROWS <br />POINTING IN BOTH DIRECTIONS. <br />2. TYPICALLY, THE MAXIMUM SPACING OF THE FIRE LANES SIGNS IS ESTABLISHED AT 100' ON <br />CENTER WITH SIGNS BEING PLACED ON BOTH SIDES OF THE FIRE LANE EASEMENT (50' ON <br />CENTER ALTERNATING SIDES). WHERE EXCESSIVE CURVATURE OF THE FIRE LANE EXISTS, <br />THE SPACING OF THE FIRE LANE SIGNAGE WILL BE INCREASED AS NEEDED. <br />3. THE SIGNS SHALL BE SET AT AN ANGLE OF NOT LESS THAN 30 DEGREES AND NOT MORE <br />THAN 45 DEGREES WITH THE CURB OR LINE OF TRAFFIC FLOW. <br />4. FIRE LANE SIGNS SHOULD BE INSTALLED 2' BEHIND CURB OR SIDEWALK. <br />5. THE CLEARANCE AT THE BOTTOM OF THE SIGN SHALL BE 7 FEET. THERE SAHLL BE NOT <br />OTHER SIGNS ATTACEHED TO THE SIGN OR THE SIGN POST. <br />6. PLACEMENT OF THESE FIRE LANE SIGNS CANNOT ENCROACH INTO TEH 29' INSIDE TURNING <br />REDIUS OF THE FIRE LANE EASEMENT, OBSTRUCT ANY FIRE HYDRANT OR FIRE DEPARTMENT <br />CONNECTION OR ENCROACH INTO TEH ACCESSIBLE ROUTE OF THE SIDEWALK AREA. <br />C9 <br />FIRE LANE SIGN <br />1 /2" = 1'-0" <br />BLUE FIELD COLOR <br />NO. 15090 IN FEDERAL <br />STANDARD 599E <br />REFLECTORIZED SIGN <br />CONSTRUCTED OF <br />PORCELAIN STEEL WITH <br />BEADED TEXT OR <br />EQUAL <br />BLUE FIELD COLOR <br />NO. 15090 IN FEDERAL <br />STANDARD 59913 <br />2" SQUARE GALVANIZED <br />STL_ POST <br />2 1/4" SQUARE <br />GALVANIZED STL. <br />ANCHOR POST <br />12" DIA. CONCRETE <br />FOOTING FOR ALL SIGN <br />POSTS <br />5 ACCESIBLE PARKING SIGN <br />9 1" = 1'-0" <br />12" <br />RESERVED - <br />PARKING <br />VAN <br />ACCESSIBLE <br />BLUE LETTERING <br />WHITE BORDER, <br />SYMBOL AND <br />LETTERING <br />80" MIN. TO TOP <br />OF WALKING <br />SURFACE <br />BLUE LETTERING <br />TOW AWAY SIGN <br />FINISH GRADE <br />DTL-Bike Rack <br />112" = <br />0 <br />0 <br />• <br />ELEVATION VIEW <br />2'-6" <br />2r-4" <br />1-7/8" OD <br />TUBING <br />GRADE <br />PRODUCT: UX190-IG(SF,SG) <br />DESCRIPTION:'U' BIKE RACK 2BIKE, <br />SURFACE OR IN GROUND MOUNT <br />ti <br />iI6—� 1--1!:_ G I —i i 1-.1 I I�11 <br />II 11IPII 4` II� <br />1-1 11,-11 11�l�l- <br />- " —11 I! 11� 11= <br />- .- 11 -11- jJ_p.w <br />I 1 ,_I 11 l I Imo: 11- <br />—� = 11=111=11� <br />IT <br />1-II•-,6 <br />09 <br />2 DTL-Pipe Bollardl <br />1/2" = l'-0" <br />i� <br />i <br />to <br />1-- <br />a'-0 314" <br />4 <br />1'-6„ <br />1 <br />� <br />09 <br />3 Plan -Site Light Pole <br />1/2" = 1'-0" <br />6" D1A. PAINTED STEEL PIPE <br />x 6'-0" FILL wl CONCRETE <br />AND MOUND TOP <br />1/2" FIBER EXPANSION <br />JOINT <br />COAT ALL EXPOSED STEEL <br />w/ASPHALTIC PAINT PRIOR <br />TO SETTING IN CONCRETE <br />2 - 10" #5 BARS WELDED <br />TO SIDE OF PIPE <br />16" DIA x 3'-6" DEEP <br />CONCRETE BASE <br />FULL CUT-OFF LIGHT <br />FIXTURE & POLE <br />WATERPROOF <br />RECEPTACLE <br />BASE COVER <br />BASE PLATE SET IN NON - <br />SHRINK GROUT <br />ANCHOR BARS. TIE TO <br />VERTICAL REBAR <br />FINISH GRADE <br />CONDUIT LOCATED 24" <br />BELOW GRADE <br />• VERTICAL REBAR <br />• HORIZONTAL TIES <br />CONCRETE BASE <br />DATE: <br />SCALE: <br />DRAWN BY: <br />CHECKED BY: <br />10.22.2021 <br />As indicated <br />DPW <br />MAE <br />HVER <br />ARCHITECTURE <br />385 IIVERFESS PARKWAY, STE 19D <br />ENGLEWOOD, CO 80112 <br />(720) 773-2800 <br />COPYRIGHT NOTICE <br />THESE PLANS ARE AN IMMIN ENT OF SERVICE AND ARE THE <br />PROPERTY OF HOVERARCHITECTURE, AND MAY NOT BE <br />DUPLICATED, DISCLOSED, OR REPRODUCED WITHOUT THE <br />WRITTEN COMSENTOF HONER ARCHITECTURE COPYRIGHTS <br />AND INFRINGEIENTSWILL BF ENFORCED AND PROSECUTED. <br />PROJECT NUMBER <br />0202.50 <br />SHEET <br />PUD-9 <br />SHEET 9 OF 14 <br />SITE DETAILS <br />