Laserfiche WebLink
Boulder Caunty1 CO <br />04040102 <br />Page 5 of 5 <br />CALL. UTILITY NOTIFICATION <br />CENTER OF COLORADO <br />1-800-922-1987 <br />CALL 2 BUSINESS DAYS IN ADVANCE <br />BEFORE YOU DIG. GRADE OR EXCAVATE <br />FOR THE MARKING OF UNDERGROUND <br />MEMBER UTILITIES. <br />Know what's below. <br />Call before you dig. <br />GENERAL IRRIGATION SPECIFICATIONS AND NOTES <br />1. <br />Lots 1 & 2, 9loak 6, Replat C, The Business Center at CTC PUD, 1st Amendment <br />Lots 1 & 2, Block 6, The Business Center at CTC Replat C Subdivision <br />Case #: PUD-000473-2023 <br />THE SYSTEM SHALL BE DESIGNED TO PROVIDE 100% COVERAGE. ANY CHANGES MADE IN THE LAYOUT DUE TO <br />FIELD CONDITIONS SHALL BE IN ACCORDANCE WITH THESE STANDARDS. CONTRACTOR SHALL NOTIFY LANDSCAPE <br />ARCHITECT OF ANY DISCREPANCIES IN PLANS OR SPECIFICATIONS PRIOR TO BEGINNING OR CONTINUING WORK. <br />THIS PLAN IS SCHEMATIC AND DUE TO THE NATURE OF CONSTRUCTION SLIGHT FIELD MODIFICATIONS MAY BE <br />NECESSARY TD IMPLEMENT PLAN. <br />2. THE CONTRACTOR SHALL MAKE NO SUBSTITUTIONS, DELETIONS, OR ADDITIONS TO THIS PLAN WITHOUT <br />APPROVAL OF THE LANDSCAPE ARCHITECT <br />3. ALL CONSTRUCTION SHALL CONFORM TO TOWN. COUNTY, STATE. AND FEDERAL REQUIREMENTS. IT SHALL BE <br />THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO ENSURE THAT ALL IRRIGATION EQUIPMENT MEETS <br />GOVERNMENT REGULATIONS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR OBTAINING ANY NECESSARY <br />PERMITS OR APPROVALS. <br />4. VERIFY LOCATIONS OF ALL UNDERGROUND UTILITIES PRIOR TO INSTALLATION OF IRRIGATION SYSTEM. ALL <br />UTILITIES AND STRUCTURES MAY NOT BE SHOWN ON THESE PLANS -CONTRACTOR SHALL FIELD VERIFY. <br />5. <br />6. <br />CONTRACTOR TO VERIFY ACTUAL AVAILABLE WATER PRESSURE BEFORE BEGINNING INSTALLATION. <br />CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IF AVAILABLE WATER PRESSURE EXCEEDS 5 PSI HIGHER OR <br />LOWER THAN AVAILABLE WATER PRESSURE. REFER TO CRITICAL ANALYSIS FOR ASSUMED STATIC PRESSURE. <br />CONTRACTOR TO FIELD VERIFY ALL POINT OF CONNECTION SOURCE INFORMATION INCLUDING PSI AND GPM <br />PRIOR TO CONSTRUCTION. <br />7. IRRIGATION DESIGN IS SCHEMATIC ONLY. FULL AND COMPLETE SHOP DRAWINGS SHALL BE SUBMITTED FOR <br />REVIEW BY THE OWNER'S REPRESENTATIVE. <br />a. CONTRACTOR SHALL COORDINATE WITH THE PLANTING PLAN FOR PLANTER BED AND TREE LOCATIONS TO <br />ENSURE ALL PLANT MATERIAL IS COVERED BY 100% HEAD -TO -HEAD IRRIGATION. <br />9. CONTRACTOR SHALL PROVIDE'AS-BUILT" DRAWINGS OF THE FINAL INSTALLATION TO OWNER AT SUBSTANTIAL <br />COMPLETION BEFORE RECEIVING FINAL PAYMENT. <br />10, IRRIGATION CONTRACTOR TO COORDINATE POWER SUPPLY TO ELECTRIC CONTROLI ERS WITH ELECTRICAL <br />CONTRACTOR. <br />11. IRRIGATION CONTRACTOR SHALL SECURE ANY AND ALL NECESSARY PERMITS FOR THE WORK PRIOR TO <br />COMMENCEMENT OF HIS OPERATIONS ON -SITE. COPIES OF THE PERMITS SHALL BE SENT TO THE <br />OWNERIGENERAL CONTRACTOR. WORK IN THE R.O.W. SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS <br />OF LOCAL AND/OR STATE JURISDICTION. <br />12. IRRIGATION LATERAL LINES, MAIN LINES AND EQUIPMENT MAY BE SHOWN OUTSIDE PROPERTY LINES ON THIS <br />PLAN, ALL IRRIGATION LINES AND EQUIPMENT ARE TO BE WITHIN AND INSTALLED WITHIN THE LIMITS OF THE <br />PROPERTY LINE. <br />13. LOCATE ALL IRRIGATION LINES WITHIN LANDSCAPED AREAS WHENEVER POSSIBLE ALL LINES UNDER PAVEMENT <br />MUST BE SLEEVED. ALL VALVES SHALL BE LOCATED WITHIN LANDSCAPED AREAS, AS SPECIFIED. <br />12. IRRIGATION SYSTEMS CONNECTED TO POTABLE WATER SUPPLY, SHALL HAVE A BACKFLOW PREVENTER <br />INSTALLED. <br />13. SUPPLY LINE AND METER TO BE PROVIDED BY GENERAL CONTRACTOR. BACKFLOW PREVENTER TO BE PROVIDED <br />BY IRRIGATION CONTRACTOR. IRRIGATION CONTRACTORS POINT OF CONNECTION TO BEGIN AFTER THE <br />IRRIGATION WATER METER. <br />14. INSTALL ALL BACKFLOW PREVENTION DEVICES AND ALL PIPING BETWEEN THE POINT OF CONNECTION AND THE <br />BACKFLOW PREVENTER AS PER LOCAL CODES. FINAL LOCATION SHALL BE DETERMINED BY THE OWNER'S <br />AUTHORIZED REPRESENTATIVE. <br />15. CONTRACTOR TO COORDINATE LOCATION OF ALL METERS AND BACKFLOW ASSEMBLIES W1TH PROJECT OWNER. <br />16. THE IRRIGATION CONTRACTOR SHALL BE DIRECTLY RESPONSIBLE FOR SLEEVING AND DIRECTIONAL BORES. <br />17. EXISTING TREES TO REMAIN ARE TO BE PROTECTED FROM DAMAGE. DO NOT TRENCH OR EXCAVATE WITHIN THE <br />CRITICAL ROOT ZONE OF ANY TREE. <br />18. ALL SLEEVES UTILIZED BY THE IRRIGATION CONTRACTOR WHETHER INSTALLED BY HIM OR NOT, SHALL BE <br />LOCATED ON THE "AS -BUILT' DRAWINGS. THE DEPTH BELOW FINISH GRADE, TO THE NEAREST FOOT OF EACH END <br />OF THE SLEEVE SHALL BE NOTED AT EACH SLEEVE LOCATION ON THE "AS -BUILT DRAWINGS. ALL SLEEVES ON <br />PLAN FOR WALL PENETRATIONS AND UNDER SIDEWALKS SHALL BE SIZED TWO PIPE SIZES GREATER THAN THE <br />PIPE IT CARRIES. ALL IRRIGATION SLEEVING TO BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR. <br />ELECTRICAL WIRES FOR IRRIGATION VALVES AND IRRIGATION LINES ARE TO BE PLACED IN SEPARATE SLEEVES. <br />SEE SLEEVING DETAIL, <br />19. ALL PRESSURIZED MAINLINES AND LATERALS UNDER PAVEMENT SHALL BE WITHIN SLEEVES AS NOTED. WHERE <br />ELECTRIC OR HYDRAULIC VALVE CONTROL UNES PASS THROUGH A SLEEVE WITH OTHER MAIN OR LATERAL LINES <br />THEY SHALL BL CONTAINED WITHIN A SEPARATE, SMALLER CONDUIT. <br />20. SLEEVES UNDER EXISTING PAVEMENT MUST BE DIRECTIONAL BORE. OPEN GUT IS NOT AN OPTION. <br />21. NUMBER THE TOP OF ALL VALVE BOX LIDS WITH MINIMUM 1" HEIGHT BLACK LETTERS TO CORRESPOND TO <br />AUTOMATIC AND GATE VALVE DESIGNATIONS. ALL HOSE BIBB VALVE BOXES SHALL BE LABELED IN A SIMILAR <br />MANNER WITH THE DESIGNATION "I-IW. LETTER OUTSIDE OF TIME CLOCK CABINETS TO CORRESPOND WITH <br />IRRIGATION CLOCK PROGRAM DESIGNATION. <br />22. THE IRRIGATION CONTRACTOR SHALL INSTALL A COLOR CODED METAL DETECTABLE MARKING TAPE WHICH <br />CLEARLY NOTES: "CAUTION: IRRIGATION LINE BURIED BELOW." THE TAPE SHALL BE INSTALLED THE FULL LENGTH <br />OF THE IRRIGATION MAINLINE. <br />23. ALL VALVES, SPLICES WITHIN CONTROL LINES, AND QUICK COUPLERS SHALL BE LOCATED WITHIN VALVE BOXES. <br />24. ALL UNSIZED PIPE SHALL BE 314" UNLESS OTHERWISE NOTED ON PLAN. SEE LATERAL PIPE SIZING REQUIREMENTS. <br />25. LOCATE ALL VALVES IN PLANTING BEDS WITH A MINIMUM OF 3'-13" FROM BACK OF CURB OR EDGE OF PAVEMENT, <br />UNLESS OTHERWISE NOTED. PIPE SIZES ON EITHER SIDE OF SECTION VALVES CONNECTING MAINLINE TO <br />SECTION LATERAL SHALL BE ONE (1) PIPE SIZE LARGER THAN VALVE SIZE WHERE MAINLINES RUN PARALLEL TO <br />PAVEMENT OR CURBING, THE MAINLINE SHALL BE OFFSET 2'-0" FROM THE EDGE OF PAVEMENT OR CURB. <br />26. IRRIGATION ZONES SHALL BE SEPARATED FOR HIGH AND LOW WATER USE REQUIREMENTS AND OPERATED ON <br />DIFFERENT WATERING CYCLES. BUBBLERS, DRIPLINE, AND SPRAY HEADS SHALL BE SEPARATED ON DIFFERENT <br />VALVES. AT NO TIME SHALL MULTIPLE IRRIGATION HEAD TYPES BE LOCATED ON THE SAME VALVE. <br />27. ALL DRIP ZONES SHALL BE INSTALLED WITH A FLUSH VALVE AND DRIP INDICATOR. <br />28. IRRIGATION CONTRACTOR TO COORDINATE WITH OWNER FOR FINAL CONTROLLER AND RAIN SENSOR LOCATIONS <br />THE CONTROLLER SHALL BE PLACED IN A LOCKING CABINET APPROPRIATE FOR ITS LOCATION. (INDOOR VS. <br />OUTDOOR USE) <br />29. IRRIGATION CONTRACTOR SHALL REVIEW WINTERIZATION PROCEDURES FOR IRRIGATION SYSTEM WITH OWNERS <br />REPRESENTATIVE. <br />30. LOCATE THE AUTOMATIC RAIN 1 FREEZE SENSOR SHUTOFF DEVICE IN AN AREA THAT IS UNOBSTRUCTED BY <br />TREES, ROOF OVERHANGS, OR ANY OTHER OVERHEAD OBJECT. THE SENSOR SHALL NOT BE PLACED WITHIN THE <br />SPRAY ZONE OF ANY SPRINKLER HEAD, INCLUDING OFF -SITE IRRIGATION. CONTRACTOR SHALL LOCATE SENSOR <br />WITHIN CLOSE PROXIMITY TO THE IRRIGATION CONTROLLER. <br />31. CONTRACTOR SHALL PERFORM HYDRO -TESTING OF MAIN LINES. <br />HYDRO -TESTING TO BE PERFORMED AS LISTED: <br />THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE FORTY-EIGHT 148) HOURS IN ADVANCE OF <br />TESTING, PRIOR TO BACKFILLING, CONTRACTOR SHALL FILL PIPING WITH WATER, IN THE PRESENCE OF THE <br />OWNER'S REPRESENTATIVE, TAKING CARE TO PURGE THE AIR FROM IT. A SMALL, HIGH PRESSURE PUMP OR <br />OTHER MEANS OF MAINTAINING A CONTINUOUS WATER SUPPLY SHALL BE CONNECTED TO THE PIPING AND SET <br />SO AS TO MAINTAIN 125 PSI FOR TWO (2) HOURS WITHOUT INTERRUPTION. CONTRACTOR SHALL MAKE ANY <br />NECESSARY CORRECTIONS AND RETEST THE SYSTEM UNTIL THE OWNER'S REPRESENTATIVE I5 SATISFIED THAT <br />THE SYSTEM IS REASONABLY SOUND. <br />32. ALL WIRING FOR CONNECTION OF THE VALVES TO THE CONTROLLER SHALL FOLLOW MANUFACTURERS <br />SPECIFICATIONS. <br />33. ALL CONTROL WIRE SHALL BE INSTALLED IN A 1 r ELECTRICAL CONDUIT. <br />34. CONTRACTOR TO MINIMIZE IRRIGATION OVERTHROW TO IMPERVIOUS AND NATURAL AREAS THROUGH FIELD <br />ADJUSTMENTS TO INDIVIDUAL HEADS. <br />35. ALL UNIMPROVED AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO THEIR ORIGINAL <br />CONDITION BY THE CONTRACTOR. <br />3e. ALL PLANT MATERIAL IN TREE HOLDING AREAS SHALL BE MANUALLY WATERED/IRRIGATED TO KEEP MOIST UNTIL <br />PLANTED. <br />FINISHED <br />GRADE/TOP <br />OF MULCH <br />III=III-Ili, h II III: <br />7-III=I 4E1HI ii1-IIIII-I1- <br />III I I I-1 J i-I <br />I'Iu <br />�I�III <br />HI1; T <br />4- <br />POP-UP SPRAY SPRINKLER ON <br />RISER AS SPECIFIED PER <br />IRRIGATION SCHEDULE <br />SCH 40 SWEEP ELBOW <br />war 17r.,....„................„....,.....„....-- <br />112" FLEX PIPE, LENGTH AS NEEDED <br />LATERAL TEE <br />.;11111 111� <br />C I a, � ,1LI• rri f <br />LATERAL PIPE <br />11 ,111-1 <br />TYPICAL SPRAY / ROTAR HEAD <br />BEGTION <br />NTS <br />AREA PERIMETER <br />FROM CONTROL VALVE <br />NOTE: <br />ALL DRIPLINE TUBING AND FITTING <br />DRIPUNE TEE CONNECTIONS SHALL BE CLAIMED <br />PER MANUFACTURERS <br />5 - LGII-ICA IRONS <br />DRIPLINE <br />'E <br />•Lni <br />1. DRIP TUBING TO BE ROUTED IN THE PLANT MATERIAL BED WITH AT <br />MAXIMUM LATERAL SPACING OF 16 INCHES. <br />2- DRIP TUBING TO BE INSTALLED IN A GRID PATTERN. DRIP TUBING SHALL <br />NOT BE $NSTALLED IN A LONG CONTINUOUS RUN. <br />3. CONTRACTOR TO REFER TO IRRIGATION PLAN FOR LOCATION OF <br />CONTROL VALVES THAT UTILIZE MULTIPLE DRIPLINE SUPPLY <br />CONNECTIONS. <br />TYPICAL DRIPLINE <br />PLAN <br />AREA PERIMETER <br />TO NEXT DRIP SUPPLY POINT <br />WHERE APPLICABLE <br />- WI-1EN DRIPUNE REQUIRES <br />MULTIPLE SUPPLY POINTS <br />EACH POINT SHALL BE <br />CONNECTED UTILIZING DRIPUNE <br />MFR FITTINGS <br />DIRECTOR OF COMMUNITY DEVELOPMENT CERTIFICATE <br />NTS <br />APPROVED THIS DAY OF , 20 BY THE <br />DIRECTOR OF COMMUNITY DEVELOPMENT OF THE CITY OF LOUISVILLE, <br />COLORADO. <br />BY <br />DIRECTOR OF COMMUNITY DEVELOPMENT <br />Kimley»> Horn <br />Expect More. Experience Better. <br />PEH ARCHITECTS <br />1319 Spruce Street Suite 207 <br />Boulder, CO 80302 <br />303-442-0408, fax: 303-447-1905 <br />e-mail; peheinz@a peharchitects.com <br />PUD AMENDMENT <br />THE PRAIRIE BUILDING <br />CTC <br />1772 Prairie Way <br />Louisville, Colorado 80027 <br />SHEET TITLE <br />IRRIGATION NOTES <br />PROJECT: 2013.15 <br />DATE: 06.09.23 <br />SHEET NUMBER <br />50F5 <br />