Laserfiche WebLink
DO NOT CUT SINGLE LEADER, <br />PRUNE DAMAGED OR DEAD <br />WOOD, AND CO -DOMINANT <br />LEADERS T LANDSCAPE <br />ARCHITECTS DIRECTION ONLY. <br />14 GAUGE GALV. WIRE <br />WITHON <br />IRE�LENGGTTHITEOF VC <br />EACH WIRE <br />SPECIFIED TREE STRAP <br />- ALIGN NW/SE <br />SPECIFIED POSTS <br />- ALIGN NW/SE <br />WRAP ENTIRE SURFACE OF <br />TRUNK UP TO SECOND BRANCH <br />WITH SPECIFIED WRAPPING <br />SECURED AT TOP AND BOTTOM <br />& AT TWO FOOT INTERVALS. <br />RE: SPECS FOR TIMING <br />RE: FINAL TOP ROOTBALL GRADE <br />PLANT TREE 3" ABOVE <br />FINAL TOP ROOTBALL GRADE <br />HAGTYTTRFOMULCIIN, P INUAREAS. <br />GRADE TO SLOPE AWAY FROM <br />ROOTBALL <br />SPECIFIED BACKFILL/FERTILIZER <br />AS PER SPECIFICATIONS <br />(IONS <br />REMOVE <br />• BURLAP BACK A2/3 WIRE, <br />UNDISTURBED OR COMPACTED <br />SUBGRADE <br />SETTLING OF ROOTBALL SHALL <br />BE CAUSE FOR REJECTION <br />DECIDUOUS TREE PLANTING <br />N.T.S. <br />VARIES <br />SEE PLANS <br />CONCRETE CURB <br />OR SIDEWALK <br />HOLD GRADE 1 IN. <br />BELOW EDGE <br />SET ORNAMENTAL <br />GRASS AT THE <br />GRADE AT WHICH <br />IT GREW <br />SPECIFIED MULCH <br />3" DEEP <br />HAND LOOSEN ROOTS <br />OF CONTAINERIZED <br />MATERIAL, TYP. <br />REMOVE CONTAINER <br />SPECIFIED BACKFILL <br />MIXTURE <br />ORNAMENTAL GRASS DETAIL <br />N.T.S. <br />CENTENNIAL VALLEY BUSINESS PARK <br />LOTS 3 AND 4, BLOCK 3, FILING N0.1 <br />PLANNED UNIT DEVELOPMENT <br />LOCATED IN THE NORTHEAST QUARTER OF SECTION 13, <br />TOWNSHIP 1 SOUTH, RANGE 70 WEST OF THE 6TH P.M. <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO. <br />DO NOT CUT LEADER <br />SPECIFIED TRUNK ATTACHMENT <br />DOUBLE STRAND SPECIFIED WIRE <br />PROVIDE 3 GUY SYSTEMS EQUI- <br />DISTANT AROUND TREE, <br />PLACE 1/2" WHITE PVC, <br />24" LENGTH ON ALL GUYING <br />SPECIFIED WO D MULCH (4" DEPTH <br />IN ALL AREAS) <br />SPECIFIED STAKES DRIVEN <br />FLUSH WITH GRADE <br />PLANT TOP OF ROOT BALL AT <br />FINAL GRADE W/ WATERING BASIN <br />IN NATIVE GRASS AREAS. PLANT <br />ROOT BALL 3" HIGHER THAN FINAL <br />GRADE IN IRRIGATED LAWN AREAS. <br />SPECIFIED BACKFILL/FERTILIZER <br />SET ROOT BALL ON EXISTING <br />UNDISTURBED SUB -SOIL. <br />NOTES: <br />1. INSTALL SPECIFIED MULCH TO DRIPLINE OF TREE WHERE PLANTED <br />IN GRASS AREAS. <br />2. DO NOT PROVIDE WATER BASIN IN IRRIGATED LAWN AREAS. <br />EVERGREEN TREE PLANTING <br />N.T.S. <br />SHRUB BED W/ SPECIFIED <br />MULCH DEPTH <br />LAWN AS SPECIFIED <br />-1/2" <br />SPECIFIED GREEN ROLL TOP <br />STEEL EDGING <br />METAL STAKES AS SPECIFIED <br />NOTE: <br />1. SET ALL EDGING 1/2" ABOVE <br />FINISH GRADE AND MULCH AS <br />SHOWN. EDGING SHALL ABUT ALL <br />CONCRETE CURBS AND WALKS <br />PERPENDICULAR AND FLUSH W/ <br />GRADES OF CONCRETE. ALL <br />JOINTS TO BE SECURELY STAKED. <br />STEEL EDGER DETAIL <br />N.T.S. <br />NOTES: <br />1. <br />PRUNE ALL DAMAGED OR DEAD <br />WOOD IMMEDIATELY PRIOR TO <br />PLANTING. <br />SET SHRUB 2" HIGHER THAN THE <br />GRADE AT WHICH IT GREW. <br />APPLY SPECIFIED MULCH <br />4" DEEP. SEE SPECIFICATIONS <br />FOR FERTILIZER APPLICATION IN <br />BACKFILL MIXTURE. <br />DIG PLANT PIT TWICE AS WIDE <br />AS THE CONTAINER OR MORE. <br />REMOVE CONTAINER. <br />LOOSEN SIDES OF PLANT PIT <br />AND ROOTBALL. <br />FILL PLANT PIT WITH SPECIFIED <br />SOIL MIX INCLUDING SPECIFIED <br />FERTILIZER. <br />CONCRETE CURB OR SIDEWALK. <br />ANY BROKEN OR CRUMBLING ROOTBALL WILL BE REJECTED. <br />REMOVING THE CONTAINERS WILL NOT BE AN EXCUSE FOR DAMAGED <br />ROOTBALLS. <br />2. HOLD GRADE 1" BELOW EDGE OF WALK OR CURB. THIS DETAIL <br />SHALL ALSO APPLY TO PERENNIAL FLOWERS IN CONTAINER. <br />3. ALL JUNIPER PLANTS SHOULD BE PLANTED SO TOP OF ROOT <br />MASS OCCURS AT FINISH GRADE OF MULCH LAYER. <br />SHRUB PLANTING DETAIL <br />N.T.S. <br />ZONE 3 <br />Root Protection <br />VARIES PER TREE SIZE <br />DECIDUOUS TREE EXTENDS FROM DRIPUNE TO DRIPUNE <br />EVERGREEN TREE COVER 1.5 TIMES THE DRIPUNE AREA <br />ZONE 2 <br />Branch Protection <br />REQUIRED IF WHEELED <br />CONSTRUCTION EQUIPMENT <br />INVOLVED WITHIN 10' OR LESS <br />RESTRICTED ZONE <br />ZONE 1 <br />Branch Protection <br />PROTECT LOWER BRANCHES <br />OF TREE CANOPY. CONTACT <br />CITY FORESTER IF ANY <br />PRUNING IS NEEDED <br />PROVIDE TEMPORARY 5' CHAIN <br />LINK FENCE PER TOWN GUIDELINES <br />AS NOTED IN NOTE #1 <br />WRAPPING OF BURLAP <br />UNDER BOARDS <br />1" BOARDS NOT LESS THAN 5' <br />LONG OR TO REACH FIRST <br />SCAFFOLD BRANCH. WIRE TO <br />HOLD BOARDS IN PLACE, <br />NO NAILS PERMITTED <br />NOTES: <br />����; ALL TREES TO RECEIVE <br />r����� ZONE 1 AND 2 PROTECTION. <br />LANDSCAPE NOTES <br />1. THIS LANDSCAPE ARCHITECTURAL SITE PLAN IS TO BE USED IN CON- <br />JUNCTION WITH THE EXISTING CIVIL, MECHANICAL, ELECTRICAL, ARCHI <br />ITECTURAL, AND IRRIGATION AS -BUILT SITE PLANS TO FORM COMPLETE <br />INFORMATION REGARDING THIS SITE. <br />2. ALL NEW LANDSCAPE AREAS SHALL BE ROTOTILLED WITH CLASS 1 ORGANIC <br />COMPOST AT A RATE OF 4 CUBIC YARDS PER 1,000 SQUARE FEET. THIS <br />PREPARATION SHALL BE THOROUGHLY INCORPORATED INTO THE TOP 6" <br />OF SOIL. <br />3. ALL DECIDUOUS AND EVERGREEN TREES ARE TO BE APPROVED BY THE <br />OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. ANY PLANT NOT <br />MEETING THE LANDSCAPE ARCHITECT'S APPROVAL WILL BE REJECTED AT <br />ANY TIME PRIOR TO FINAL ACCEPTANCE. <br />4. ALL TREES TO BE STAKED OR GUYED AS PER PLANT LIST AND DETAILS. <br />5. ALL TREE AND SHRUB BED LOCATIONS ARE TO BE STAKED OUT ON SITE <br />FOR APPROVAL BY THE OWNER'S REPRESENTATIVE PRIOR TO INSTALL- <br />ATION. <br />7. ALL SHRUB/ORNAMENTAL GRASS BEDS SHALL BE MULCHED WITH 4" DEPTH <br />3/4" CRUSHED GRANITE ROCK MULCH OVER SPECIFIED FILTER FABRIC. <br />8. ALL MULCH AREAS ADJACENT TO THE BUILDING SHALL BE MULCHED WITH <br />4" DEPTH 3/4" CRUSHED GRANITE ROCK MULCH OVER SPECIFIED FILTER <br />FABRIC. <br />9. ALL PERENNIAL BEDS SHALL BE MULCHED WITH 4" DEPTH WESTERN RED <br />CEDAR WOOD MULCH. DO NOT PLACE FILTER FABRIC UNDER WOOD MULCH. <br />10. ALL SHRUB AND PERENNIAL BEDS IN THE THERAPY GARDEN SHALL BE <br />MULCHED WITH 4" DEPTH WESTERN RED CEDAR WOOD MULCH. DO NOT <br />PLACE FILTER FABRIC UNDER WOOD MULCH. <br />PROVIDE LARGEST PROTECTION <br />ZONE BY EITHER USING DRIPLINE <br />OR 1' PER 1" DBH, WHICHEVER <br />IS LARGEST. <br />SEE CITY FORESTER PRIOR <br />TO AERATION. <br />TREE PROTECTION DETAIL <br />N.T.S. <br />TREE PRESERVATION AND <br />REMOVAL NOTES: <br />1. BARRICADES SHALL HAVE A 1 -FOOT RADIUS PER INCH OF TRUNK DIAMETER, <br />WITH A WOOD CHIP MULCH 6 TO 8 INCHES DEEP EXTENDING BEYOND THE <br />BARRIER TO THE DRIPLINE, IF NEEDED. IF LOW BRANCHES WILL BE KEPT, <br />PLACE NE FENCE OUTSIDE THE DRIPLINE. EXAMINE TREES AND BARRICADES <br />AT LEAST ONCE A WEEK DURING CONSTRUCTION. <br />WITHIN THE DRIP LINE OF PROTECTED EXISTING TREES, THERE SHALL BE NO <br />CUT OR FILL UNLESS THE CONSULTING ARBORIST HAS EVALUATED AND APPROVED <br />THE DISTURBANCE. TREE ROOTS ON TREES IN NATIVE AREAS SUCH AS THIS <br />CAN BE FOUND AT THE VERY SURFACE OF THE SOIL, AND AS MANY OF <br />THESE ARE FEEDER ROOTS, NO DISTURBANCE OF ANY KIND SHALL BE <br />PERMITTED UNLESS APPROVED BY THE CONSULTING ARBORIST. <br />2. ALL EXISTING PRESERVED SPRUCE TREES SHALL BE TREATED FOR Ips BEETLES <br />TWICE PER YEAR (MARCH AND JULY). <br />3. ALL TRENCHING, BORING, AND PUSHING OF UTILITIES THROUGH THE ROOT <br />ZONES OF EXISTING SHALL BE AVOIDED. <br />4. IF DAMAGE OCCURS TO ROOTS OF EXISTING TREES, THE ROOTS SHALL BE <br />PRUNED AND COVERED WITH SOIL OR MOIST BURLAP WITHIN TWO HOURS. <br />5. THE CONSULTING ARBORIST MUST BE CONTACTED PRIOR TO ANY NECESSARY CUT <br />AND FILL EARTHWORK WITHIN NE DRIPLINE OF AN EXISTING PRESERVED TREE. <br />6. EARTHWORK SHALL NOT BE PLACED ADJACENT TO TREE TRUNKS. <br />7. ALL CONSTRUCTION ACTIVITY SHALL BE PROHIBITED WITHIN THE FENCED <br />ROOT/DRIP LINE IN ORDER TO PREVENT SOIL COMPACTION. <br />8. NO CONSTRUCTION RELATED WASH-OUT (E.G., LIME, ACID, CONCRETE) SHOULD <br />OCCUR WITHIN 30 FEET OF ANY TREE TRUNK. <br />9. A CERTIFIED ARBORIST SHALL PRUNE ALL EXISTING PRESERVED TREES. <br />10. SUPPLEMENTAL WATERING IS NOT RECOMMENDED UNLESS APPROVED BY THE <br />CONSULTING ARBORIST. <br />site design <br />landscape architecture <br />site planning <br />700 colorado boulevard, suite 131 <br />denver, colorado 80206 <br />303,512.0549 www.meuran.com <br />12-3-15 SUBMITTAL #1 <br />2-12-16 SUBMITTAL #2 <br />10-14-16 MYLAR SET <br />11. ALL NEW SHRUB BEDS AND MULCH AREAS ARE TO BE CONTAINED WITH <br />SPECIFIED ROLL TOP STEEL EDGER (NOT REQUIRED AT CURB, WALKS OR <br />BUILDING). PLACE STEEL EDGER BETWEEN ALL ROCK AND WOOD MULCH <br />BEDS. <br />12. ALL NEW LANDSCAPE AREAS, INCLUDING THE IRRGATED SEED MIX, WILL <br />BE WATERED WITH AN AUTOMATIC UNDERGROUND IRRIGATION SYSTEM. <br />ALL TURF AREAS LESS THAN 15' IN WIDTH SHALL HAVE LOW -ANGLE SPRAY <br />NOZZLES DESIGNED FOR THE SPECIFIED WIDTH. ALL TURF AREAS GREATER <br />THAN 15' SHALL BE IRRIGATED WITH GEAR -DRIVEN ROTORS WITH LOW <br />ANGLE NOZZLES ON SEPARATE STATIONS. ALL SPRAY HEADS SHALL BE <br />PRESSURE REDUCING DESIGNED TO PREVENT LOW HEAD DRAINAGE. ALL <br />IRRIGATED SOD AND SEED AREAS SHALL BE SEPARATELY ZONED. ALL <br />SHRUB BEDS SHALL BE IRRIGATED WITH A SEPARATELY ZONED DRIP SYSTEM <br />PROVIDING FULL COVERAGE TO EACH PLANT. A RAIN SENSOR SYSTEM <br />SHALL BE ADDED TO THE NEW IRRIGATION SYSTEM. THE LANDSCAPE <br />CONTRACTOR SHALL SUPPLY AN IRRIGATION SYTEM DESIGN AND SUBMITTALS <br />FOR APPROVAL BY THE LANDSCAPE ARCHITECT PRIOR TO INSTALLATION. <br />13. IRRIGATION SYSTEM DESIGN SHALL NOT OVERSPRAY ONTO PAVED SURFACES <br />CENTENNIAL PARKWAY. PUBLIC WORKS TO APPROVE SPRINKLER SPRAY <br />PATTERNS IN RIGHT-OF-WAY PRIOR TO CONSTRUCTION ACCEPTANCE. <br />14. ALL EXISITNG TREES AJACENT TO THE EAST PROPERTY LINE SHALL BE <br />PRUNED AND/OR LIMBED UP ON THIS PROPERTY TO AVOID ANY LONG <br />TERM DAMAGE DUE TO CONSTRUCTION. <br />15. RIGHT OF WAY AND ASSOCIATED IMPROVEMENTS SHALL BE PRIVATELY <br />MAINTAINED AND SHALL INCLUDE LANDSCAPE MAINTENANCE AND <br />SNOW REMOVAL. <br />16. EVERGREEN TREES SHALL NOT BE PLANTED WITHIN 10' OF PUBLIC WALK/ <br />CURB OR CITY UTILITY. DECIDUOUS TREES SHALL NOT BE PLANTED <br />WITHIN 5' OF PUBLIC WALK/CURB OR CITY UTILITY. <br />LANDSCAPE NOTES <br />& DETAILS <br />SHEET 7 OF 11 <br />1 <br />