Boulder County, CO 03718414 <br />a ,1 <br />r /////////////////////// ////////////// ///////////// // /////////////// /////ii iiii/A <br />1 DEMO EXISTING EAST ELEVATION <br />D1.1 3/16" = 1 '- <br />DX9R2 <br />W <br />, ririr <br />PREPARE EXISTING TO <br />RECEIVE NEW WALL FINISH <br />DEMO EXISTING WEST ELEVATION <br />D1.1 <br />3/16" = 1'- <br />3 <br />0 <br />N <br />�r <br />D)OHE <br />PREPARE EXISTING TO <br />RECEIVE NEW WALL FINISH <br />REMOVE APPLICABLE EXISTING FRAMING AND GLAZING <br />ALONG FRONT WALL WHERE INDICATED. RETAIN ALL <br />STRUCTURAL COMPONENTS UNLESS OTHERWISE NOTED. <br />REFER TO CONSTRUCTION FLOOR PLAN TO VERIFY <br />EXTENT OF DEMOLITION REQUIRED <br />P. <br />/2///////////////)////////////// <br />//////////////////////////////////////////////////A <br />\___REMOVE APPLICABLE EXISTING FRAMING AND GLAZING <br />ALONG FRONT WALL WHERE INDICATED. RETAIN ALL <br />STRUCTURAL COMPONENTS UNLESS OTHERWISE NOTED. <br />REFER TO CONSTRUCTION FLOOR PLAN TO VERIFY <br />EXTENT OF DEMOLITION REQUIRED <br />''A1ii1`< <br />// <br />/� <br /># <br />/j <br />// <br />DEMO EXISTING NORTH ELEVATION <br />.1 3/16" = 1'- <br />DEMOLITION KEY NOTES: <br />REMOVE EXISTING BUILDING SIGNAGE EXTEND <br />REUSE EXISTING SUPPORTS <br />CANOPY SYSTEM TO BE RECLADED. REF <br />A2.0. <br />AS NECESSARY: <br />REMOVE EXISTING EXTERIOR PLAYPLACE FENCING AND EXISTING SAFETY <br />SURFACE <br />REMOVE EXISTING EXTERIOR TABLES AND CHAIRS <br />REMOVE EXISTING CONCRETE CURBS AS NECESSARY <br />REMOVE EXISTING EXTERIOR DECORATIVE WOOD TRIM <br />REMOVE EXISTING ASPHALT PARKING LOT GUARDRAILS AND BOLLARDS AS <br />REQUIRED TO ACCOMMODATE NEW WORK <br />1. THESE DRAWINGS WERE PREPARED BASED ON INFORMATION ATTAINED FROM A SITE SURVEY. <br />CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO DEMOLITION & NOTIFY <br />THIS OFFICE IN CASE OF DISCREPANCIES ASAP. DEMOLITION IS TO BE EXECUTED SO AS NOT TO <br />DISTURB EXISTING STRUCTURAL & ROOFING SYSTEMS, AND OTHER AREAS THAT ARE INTENDED TO <br />REMAIN INTACT. VERIFY ALL CONSTRUCTION TO BE REMOVED THAT IS NOT INTEGRAL TO <br />STRUCTURAL SYSTEM PRIOR TO DEMOLITION. <br />2. ALL DIMENSIONS SHOWN AS EXISTING SHOULD BE FIELD VERIFIED BY CONTRACTOR PRIOR TO <br />DEMOLITION. VERIFY ALL DEMOLITION WORK W/ NEW CONSTRUCTION & INSTALLATION DRAWINGS <br />PRIOR TO BEGINNING CONSTRUCTION. <br />3. DEMOLITION CONTRACTOR TO COORDINATE & REVIEW ALL CONSTRUCTION DOCUMENTS & <br />DETERMINE THE EXTENT OF DEMOLITION WORK & BECOME FAMILIAR WITH THEM THOROUGHLY <br />BEFORE PERFORMING ANY DEMOLITION WORK. BY THE ACT OF STARTING DEMOLITION, THE <br />CONTRACTOR WILL BE DEEMED TO HAVE COMPLIED WITH THE FOREGOING, TO HAVE ACCEPTED <br />SUCH CONDITIONS, AND TO HAVE MADE THE NECESSARY ALLOWANCES IN PREPARING HIS BID. <br />r• <br />n <br />n <br />4 DEMO EXISTING SOUTH ELEVATION <br />D1.1 3/16" = 1' <br />4. ELECTRICAL DEMOLITION NOTE: REFER TO ELECTRICAL DRAWINGS FOR DETAILED ELECTRICAL <br />DEMOLITION NOTES. <br />5. VERIFY DISPOSITION OF ALL FURNISHINGS, MILLWORK, LIGHTING FIXTURES, ETC. TO BE <br />REMOVED W/ OWNER. ALL ITEMS TO BE DISPOSED SHALL BE DISPOSED OF OFF -SITE AND IN <br />AN EXPEDITIOUS MANNER. <br />6. ROOFING CONTRACTOR TO FIELD INSPECT EXISTING ROOF FOR WEATHER TIGHTNESS & <br />PROPER DRAINAGE PRIOR TO BID. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD <br />VERIFICATION OF EXISTING ROOF CONDITION AND FOR INCLUDING ANY NECESSARY REPAIR COSTS <br />IN BID. <br />7. SAWCUT & REMOVE EXISTING SLABS AS REQUIRED FOR UNDERGROUND ELECTRICAL & <br />PLUMBING LINES. REFER TO PLUMBING, ELECTRICAL & KITCHEN DRAWINGS FOR ALL SAWCUTS & <br />TRENCHING WORK REQUIRED. ALL CONCRETE FLOOR WORK TO BE FINISHED FLUSH WITH <br />EXISTING FLOOR. DOWEL NEW SLABS TO EXISTING W/ #4 REBAR © 24" O.C. EACH SIDE <br />(STAGGERED). REBAR TO EXTEND 6" INTO EXISTING SLAB & ACROSS CUT OPENING. SECURE <br />REBAR INTO EXISTING SLAB W/ EPDXY GROUT. REPLACE OR REPAIR ANY VAPOR BARRIERS <br />DISTURBED DURING EXCAVATIONS. <br />8. CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING AS REQUIRED TO MAINTAIN <br />STRUCTURAL STABILITY OF THE EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION. <br />9. PROTECT FROM DAMAGE DURING CONSTRUCTION ALL EXISTING WALLS, FLOORS, CEILINGS, ETC. <br />THAT ARE TO REMAIN. CONTRACTOR TO PATCH & REPAIR ANY DAMAGED PORTIONS OF THE <br />EXISTING BUILDING AS REQUIRED TO MATCH THE EXISTING ADJACENT CONSTRUCTION & FINISHES. <br />10. THIS PLAN INDICATES A GENERAL SCOPE OF WORK TO BE PERFORMED AND DOES NOT <br />RELIEVE THE CONTRACTOR TO COMPLETE THE BUILDING MODIFICATIONS AS SHOWN AND REQUIRED <br />BY THE CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL & HVAC <br />WORK. <br />11. IF CONTRACTOR ENCOUNTERS ANY HAZARDOUS MATERIALS DURING DEMOLITION OR <br />CONSTRUCTION, HE SHALL IMMEDIATELY SUSPEND WORK & NOTIFY THE MCDONALD'S AREA <br />CONSTRUCTION MANAGER BEFORE PROCEEDING. <br />12. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER & IN STRICT ACCORDANCE <br />WITH OSHA REGULATIONS. <br />13. THE SUB -CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. THE WORK <br />INCLUDES, BUT IS NOT LIMITED TO THE DEMOLITION AND REMOVAL OF ANY WALLS, COUNTERS, <br />FURNITURE, BULKHEADS, DOORS, PLUMBING, MECHANICAL AND ELECTRICAL ITEMS INCLUDING <br />CONDUITS AND DUCTWORK AS SHOWN ON THE DRAWINGS OR AS REQUIRED TO COMPLETE THE <br />INSTALLATION OF THE NEW WORK FOR A COMPLETE JOB. <br />14. REMOVE ANY SINKS, WATER CLOSETS, URINALS, LAVATORIES, FLOOR DRAINS, NOTED ON <br />DRAWINGS AS WELL AS ALL ASSOCIATED PLUMBING ACCESSORIES. CAP, PLUG ALL ABANDONED <br />SUPPLY & WASTE LINES. PATCH & SEAL ALL FLOOR PENETRATIONS. SEE MECHANICAL & <br />PLUMBING DRAWINGS FOR DETAILED DEMOLITION NOTES. <br />15. WHEN UTILITIES ARE REMOVED, CAP & SEAL A MINIMUM OF 8" BELOW FINISH FLOOR OR <br />MINIMUM OF 6" ABOVE FINISH CEILING. <br />Na <br />DA1E <br />R£NSLW DESCRIPRON <br />CM ENGMERNS CONSIZMW <br />2595 <br />FRANKTOWN, <br />Strate?ic Land Solutions, Inc. <br />Civil Engineering . Land Planning . Entldements <br />PONDEROSA ROAD <br />CO 80116 <br />720.384.7661 Phone <br />rpalmer@strategicls.net <br />Robert J. Palmer, PE <br />President <br />CI <br />1 <br />ic <br />ROCKY MOUNTAIN REGION <br />4643 S. ULSTER STREET, SUITE 1300, DENVER, COLORADO 80237 <br />I—QoII <br />/ I 0 <br />i <br />O , <br />C) g 41 <br />© % g <br />1 % <br />OFFICE <br />ADDRESS <br />SNIT "MESS <br />939 W. DILLON ROAD <br />an' SYNE- <br />LOUISVILLE COLORADO <br />COURT <br />BOULDER <br />sWF SRWE £y <br />50294 <br />x <br />x <br />x <br />If <br />i <br />ti <br />SAVE* as noted <br />BOWAN <br />1447E 11/02/2018 <br />alcD P/Cat PROPHET <br />DESISNED fft, RJP <br />MIN Br RJ P <br />' WE <br />CURRENT.DWG <br />SS JV: 14-001-47 <br />a<tz�'FD fir <br />RJ P <br />L il1C1111E <br />D1.1 <br />1 <br />ItL`ELS <br />5 OF <br />6 <br />