Laserfiche WebLink
Boulder County, CO <br />03947119 <br />9of10 - <br />DEMO EXISTING EAST ELEVATION <br />3/16" = 1'-0" <br />rN, <br />0 0 n <br />I//////////////1_///.////////////L/ /////////////////////// <br />McDONALDS PUD AMENDMENT #4 <br />LOT 4. CENTENNIAL VALLEY, PARCEL "0" FILING NO. 3, <br />AMENDED FINAL P.U.D. <br />STORE #50-0294 <br />939 W. DILLON ROAD <br />LOUISVILLE, COLORADO <br />DDIOHE <br />PREPARE EXISTING TO <br />RECEIVE NEW WALL FINISH <br />DEMO EXISTING WEST ELEVATION <br />3/16" = <br />L7 LI <br />DEMO EXISTING NORTH ELEVATION <br />3/16" = 1'-0" <br />DEMOLITION KEY NOTLI <br />REMOVE EXISTING BUILDING SIGNAGE EXTEND <br />REUSE EXISTING SUPPORTS <br />CANOPY SYSTEM TO BE RECLADED. REF <br />A2.0. <br />AS NECESSARY: <br />REMOVE EXISTING EXTERIOR PLAYPLACE FENCING AND EXISTING SAFETY <br />SURFACE <br />REMOVE EXISTING EXTERIOR TABLES AND CHAIRS <br />REMOVE EXISTING CONCRETE CURBS AS NECESSARY <br />REMOVE EXISTING EXTERIOR DECORATIVE WOOD TRIM <br />REMOVE EXISTING ASPHALT PARKING LOT GUARDRAILS AND BOLLARDS AS <br />REQUIRED TO ACCOMMODATE NEW WORK <br />\\\) <br />/////////////////////////// <br />PREPARE EXISTING TO <br />RECEIVE NEW WALL FINISH <br />0 <br />.M"/ie <br />D)©ELEiCara0 <br />/X <br />\\_ REMOVE APPLICABLE EXISTING FRAMING AND GLAZING <br />ALONG FRONT WALL WHERE INDICATED. RETAIN ALL <br />STRUCTURAL COMPONENTS UNLESS OTHERWISE NOTED. <br />REFER TO CONSTRUCTION FLOOR PLAN TO VERIFY <br />EXTENT OF DEMOLITION REQUIRED <br />I7 <br />/,//////////////////////////////////////////////////////////'///////////////////////,I <br />REMOVE APPLICABLE EXISTING FRAMING AND GLAZING <br />ALONG FRONT WALL WHERE INDICATED. RETAIN ALL <br />STRUCTURAL COMPONENTS UNLESS OTHERWISE NOTED. <br />REFER TO CONSTRUCTION FLOOR PLAN TO VERIFY <br />EXTENT OF DEMOLITION REQUIRED <br />o)OI n��. C <br />/////,/(// I <br />1. THESE DRAWINGS WERE PREPARED BASED ON INFORMATION ATTAINED FROM A SITE SURVEY. <br />CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN FIELD PRIOR TO DEMOLITION & NOTIFY <br />THIS OFFICE IN CASE OF DISCREPANCIES ASAP. DEMOLITION IS TO BE EXECUTED SO AS NOT TO <br />DISTURB EXISTING STRUCTURAL & ROOFING SYSTEMS. AND OTHER AREAS THAT ARE INTENDED TO <br />REMAIN INTACT. VERIFY ALL CONSTRUCTION TO BE REMOVED THAT IS NOT INTEGRAL TO <br />STRUCTURAL SYSTEM PRIOR TO DEMOLITION. <br />2. ALL DIMENSIONS SHOWN AS EXISTING SHOULD BE FIELD VERIFIED BY CONTRACTOR PRIOR TO <br />DEMOLITION. VERIFY ALL DEMOLITION WORK W/ NEW CONSTRUCTION & INSTALLATION DRAWINGS <br />PRIOR TO BEGINNING CONSTRUCTION. <br />3. DEMOLITION CONTRACTOR TO COORDINATE & REVIEW ALL CONSTRUCTION DOCUMENTS & <br />DETERMINE THE EXTENT OF DEMOLITION WORK & BECOME FAMILIAR WITH THEM THOROUGHLY <br />STARTING DEMOLITION. DEMOLITION WORK. BY THE ACT OF STAR I D MOLIT ON THE <br />BEFORE PERFORMING ANY . <br />CONTRACTOR WILL BE DEEMED TO HAVE COMPLIED WITH THE FOREGOING, TO HAVE ACCEPTED <br />SUCH CONDITIONS. AND TO HAVE MADE THE NECESSARY ALLOWANCES IN PREPARING HIS BID. <br />DEMO EXISTING SOUTH ELEVATION <br />3/16" - 1'-Q" <br />4. ELECTRICAL DEMOUTION NOTE: REFER TO ELECTRICAL DRAWINGS FOR DETAILED ELECTRICAL <br />DEMOLITION NOTES. <br />5. VERIFY DISPOSITION OF ALL FURNISHINGS, MILLWORK. LIGHTING FIXTURES, ETC. TO BE <br />REMOVED W/ OWNER, ALL ITEMS TO BE DISPOSED SHALL BE DISPOSED OF OFF —SITE AND IN <br />AN EXPEDITIOUS MANNER. <br />6. ROOFING CONTRACTOR TO FIELD INSPECT EXISTING ROOF FOR WEATHER TIGHTNESS & <br />PROPER DRAINAGE PRIOR TO BIO. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD <br />VERIFICATION OF EXISTING ROOF CONDITION AND FOR INCLUDING ANY NECESSARY REPAIR COSTS <br />IN BID. <br />7. SAWCUT & REMOVE EXISTING SLABS AS REQUIRED FOR UNDERGROUND ELECTRICAL & <br />PLUMBING LINES. REFER TO PLUMBING, ELECTRICAL & KITCHEN DRAWINGS FOR ALL SAWCUTS & <br />TRENCHING WORK REQUIRED. ALL CONCRETE FLOOR WORK TO BE FINISHED FLUSH WITH <br />EXISTING FLOOR. DOWEL NEW SLABS TO EXISTING W/ #4 REBAR 24" O.C. EACH SIDE <br />(STAGGERED). REBAR TO EXTEND 6" INTO EXISTING SLAB & ACROSS CUT OPENING. SECURE <br />REBAR INTO EXISTING SLAB W/ EPDXY GROUT. REPLACE OR REPAIR ANY VAPOR BARRIERS <br />DISTURBED DURING EXCAVATIONS. <br />8. CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING AS REQUIRED TO MAINTAIN <br />STRUCTURAL STABILITY OF THE EXISTING STRUCTURE DURING ALL PHASES OF CONSTRUCTION. <br />9. PROTECT FROM DAMAGE DURING CONSTRUCTION ALL EXISTING WALLS. FLOORS. CEILINGS, ETC. <br />THAT ARE TO REMAIN. CONTRACTOR TO PATCH & REPAIR ANY DAMAGED PORTIONS OF THE <br />EXISTING BUILDING AS REQUIRED TO MATCH THE EXISTING ADJACENT CONSTRUCTION & FINISHES. <br />10. THIS PLAN INDICATES A GENERAL SCOPE OF' WORK TO BE PERFORMED AND DOES NOT <br />RELIEVE THE CONTRACTOR TO COMPLETE THE BUILDING MODIFICATIONS AS SHOWN AND REQUIRED <br />BY THE CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL & HVAC <br />WORK_ <br />11. IF CONTRACTOR ENCOUNTERS ANY HAZARDOUS MATERIALS DURING DEMOLITION OR <br />CONSTRUCTION, HE SHALL IMMEDIATELY SUSPEND WORK & NOTIFY THE MCDONALD'S AREA <br />CONSTRUCTION MANAGER BEFORE PROCEEDING. <br />12. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER & IN STRICT ACCORDANCE <br />WITH OSHA REGULATIONS. <br />13. THE SUB —CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. THE WORK <br />INCLUDES, BUT IS NOT UMITED TO THE DEMOUTION AND REMOVAL OF ANY WALLS, COUNTERS, <br />FURNITURE, BULKHEADS. DOORS, PLUMBING, MECHANICAL AND ELECTRICAL ITEMS INCLUDING <br />CONDUITS AND DUCTWORK AS SHOWN ON THE DRAWINGS OR AS REQUIRED TO COMPLETE THE <br />INSTALLATION OF THE NEW WORK FOR A COMPLETE JOB. <br />14. REMOVE ANY SINKS, WATER CLOSETS, URINALS, LAVATORIES, FLOOR DRAINS, NOTED ON <br />DRAWINGS AS WELL AS ALL ASSOCIATED PLUMBING ACCESSORIES. CAP, PLUG ALL ABANDONED <br />SUPPLY & WASTE LINES. PATCH & SEAL ALL FLOOR PENETRATIONS. SEE MECHANICAL & <br />PLUMBING DRAWINGS FOR DETAILED DEMOLITION NOTES. <br />15. WHEN UTILITIES ARE REMOVED, CAP & SEAL A MINIMUM OF 8" BELOW FINISH FLOOR OR A <br />MINIMUM OF 6" ABOVE FINISH CEILING. <br />DATE ► EIM/ clr> nrw I <br />itratevic Land iolutiani, Inc. <br />❑v,l E.gineedng • land Planning • Entitlements <br />2595 PONDEROSA ROAD <br />FRANKTOWN, CO 80116 <br />720.384.1661 Phone <br />rpalnier@strategicle.net <br />Robert J. Palmer, PE <br />President <br />O <br />a 9 <br />O 0 <br />ce be, <br />z 0 <br />I 8 <br />9 <br />• <br />IW <br />J <br />—J <br />t <br />rin <br />W <br />O <br />m <br />N <br />O <br />L <br />ROCKY MOUNTAIN REGION <br />W <br />U <br />Li <br />La- <br />• <br />ADDRESS 4643 S. ULSTER STREET, SUITE 1300, DENVER, COLORADO 80237 <br />NNE le RE <br />as noted ' BOWAN <br />DVe 11/02/2018 ' pM PROPHET <br />WNW a! <br />RJP <br />R3P <br />RIP <br />I <br />FIE NNE <br />CURREIVT.DWG <br />$' ,/Y!` U1-L 1-47 <br />D1.1 <br />9 of 10 <br />