power. Emergency power systems are those required for electrical loads <br />where interruption of the primary power could result in loss of human life <br />or serious injuries. <br />Energy Use Intensity (EUI): The annual building site energy use per <br />square foot of gross floor area in units of kBTU/sq ft. <br />Residential Building: For this code, includes detached one- and two- <br />family dwellings and multiple single-family dwellings (townhouses) R-3 <br />and R-4 buildings three stories or less in height above grade plane. <br />Standby Power System: A source of automatic electric power of a <br />required capacity and duration to operate required building, hazardous <br />materials or ventilation systems in the event of a failure of the primary <br />power. Standby power systems are those required for electrical loads <br />where interruption of the primary power could create hazards or hamper <br />rescue or fire -fighting operations. <br />Tenant Finish. The first tenant occupying a space(s) in a core and shell. <br />Multiple tenants may be considered as a tenant finish until the entire <br />space within the core and shell has had a tenant. Once a space within <br />a core and shell has been occupied it becomes an existing building. <br />4. C401.2. Commercial buildings shall comply with Sectien G401 1 one <br />of the followina. as aaalicable <br />C401.2.1 Performance targets. New commercial building types included <br />in the scope of Appendix PT shall comply with Appendix PT and <br />Sections C403.2.4 and C404.10. <br />C401.2.2 Core and shell. Core and shell buildings shall comply with the <br />provisions of Section C402.1.3 through C402.5. When mechanical <br />systems are installed, core and shell buildings shall also meet the <br />provisions in C403.2.4, C404.10, and Section C408. <br />C401.2.2.1 Core and shell buildings shall submit a letter of agreement <br />to the City stating the tenant spaces included in the scope of Appendix <br />PT shall meet the EUI target established in Table PT103 and shall <br />include these requirements in their lease or purchase agreements. <br />C401.2.3 Tenant finish. Tenant finishes included in the scope of <br />Appendix PT shall comply with Appendix PT and C403.2.4 and C404.10. <br />All other tenant finishes shall comply with the Prescriptive Compliance <br />option, which requires compliance with Sections C401.3, C401.4, C402 <br />through C406, and C408. <br />Ordinance No. , Series 2024 <br />Page 4 of 30 <br />17 <br />