Laserfiche WebLink
Dacuslgti Envelope ID: 9D207990-DEBB-4CC 1-835F-5FF59E54101 E <br />04104510 10/0612025 08:18 AM <br />RF: $43.00 Page 1 of 13 <br />Electronically recorded in Boulder County Colorado. Recorded as received. <br />IDDSG SITE DATA TABLE <br />TOTAL SITE AREA <br />SITE COVERAGE <br />BUILDING <br />PARKING <br />DRIVEWAY <br />SIDEWALKS <br />LANDSCAPE COVERAGE <br />LANDSCAPE AREA <br />HARDSCAPE AREA <br />TOTAL <br />BUILDING HEIGHT <br />SETBACKS <br />NORTH <br />WEST <br />SOUTH <br />EAST <br />PARKING SPACES <br />STANDARD <br />ACCESSIBLE <br />EV INSTALLED (GROUP B OCC_) <br />EV READY (GROUP B OCC ) <br />EV CAPABLE (GROUP B OCC.) <br />BICYCLE <br />PARKING SETBACKS <br />NORTH <br />WEST <br />SOUTH <br />EAST <br />WAIVER REQUESTS <br />REQUIRED <br />25% (9,013 SF) <br />75% (27,038 SF) <br />PROPOSED <br />36,051 SF <br />16,294 SF <br />2, 910 SF <br />5,988 SF <br />2,233 SF <br />24% (8,626 SF) <br />76% (27,425 SF) <br />40.-0" MAX 26'41" <br />1Y-0" <br />15'-0" <br />10.-0" <br />30'-IT <br />23 SPACES <br />22 <br />1 <br />2% <br />8% <br />10% <br />3 <br />10'-0" <br />1U0%0' <br />20'-0" <br />10r-0" <br />13'-6' <br />55-0" <br />33'-0 <br />14 SPACES <br />13 <br />fi <br />fi <br />1 <br />2 <br />4 <br />137-0" <br />4'-0" <br />10'-0" <br />20'-0- <br />BELOW IS A LIST OF WAIVER REQUESTS WITH COMMERCIAL DEVELOPMENT DESIGN STANDARDS AND GUIDELINES, <br />INDUSTRIAL DEVELOPMENT DESIGN STANDARDS AND GUIDELINES. OR LOUISVILLE MUNICIPAL CODE SECTION(S) IDENTIFIED <br />WAIVER REQUEST IDDSG REQUIREMENTS REQUEST TO WAVE <br />#1: PARKING REDUCTION <br />lit' PARKING SPACE MINIMUM <br />SIZE REDUCTION <br />#3: DRIVE AISLE WIDTH REDUCTION <br />#4: BUFFER ZONE REDUCTION <br />#5: REAR SETBACK <br />ENCROACHMENT <br />NOTES <br />0,828 ACRES <br />Pet IDDSG 1.4.B <br />Per IDDSG 1.4.A <br />Per IDDSG 4 2.8 <br />Per IDDSG 1.2.A <br />Per IDDSG 2.2.1.E <br />Per DBC 2021 Table 11062 <br />Table CV502.1 <br />Table CV502.1 <br />Table CV502.1 <br />Per IDDSG 3.2.0 <br />Per IDDSG 12_B <br />IDDSG §2 2.1.E SURFACE PARKING LOT REQUEST TO WAIVE <br />REQUIREMENTS' • OFFICE SPACE 2 SPACES/1000 SF (1'500) <br />• OFFICE SPACE 4 SPACES/1000 SF 0:250) • WAREHOUSE SPACE' 0.5 SPACE/1000 SF <br />• WAREHOUSE SPACE 1 SPACE/1000 SF (0.5:1000) <br />(1:1000) <br />IDDSG §2.2.1.1 SURFACE PARKING LOT REQUEST TO WAVE: <br />REQUIREMENTS' • 8'-6" WIDE X 1T-6" DEEP STANDARD <br />• 9%0" WIDE X 19'-0' DEEP STANDARD PARKING SPACE <br />PARKING SPACE <br />IDDSG §2.2.1.0 VEHICULAR ACCESS REQUIREMENT: <br />• 28 0" WIDE TWO-WAY ACCESS DRIVE <br />IDDSG §5.2 PERIMETER LANDSCAPING ADJACENT <br />TO ABUTTING PROPERTY REQUIREMENT <br />• 10'-0" BUFFER ZONE <br />IDDSG §1.2 BUILDING AND PARKING SETBACK <br />REQUIREMENTS. <br />• 15'-0' REAR YARD SETBACK <br />REQUEST TO WAVE: <br />• 24'-0' WIDE TWO-WAY ACCESS DRIVE <br />REQUEST TO WAIVE: <br />• 7-2 1/2" BUFFER ZONE AT WEST <br />• 7'-0" BUFFER ZONE AT SOUTH <br />REQUEST TO WAIVE <br />1. 1'-0" BUILDING ENCROACHMENT <br />INTO SETBACK <br />#6: MINIMUM LANDSCAPE IDDSG §1 4.B SITE COVERAGE REQUIRED- REQUEST TO WAIVE. <br />REQUIREMENT REDUCTION • 25% LANDSCAPE COVERAGE • 24% LANDSCAPE COVERAGE <br />#7• SITE AND DRIVEWAY <br />ACCESS MINIMUM <br />#8: PERIMETER LANDSCAPING <br />ADJACENT TO ABUTTING PROPERTY <br />IDDSG §2.1.1.F DRIVEWAYS REQUIREMENT <br />• MUST BE75'-0" MINIMUM FROM <br />NEIGHBORING DRIVEWAY <br />IDDSG §5 2.A.1 PROVIDE 1 TREE FOR EVERY 30 <br />LINEAR FEET OF PROPERTY LINE <br />REQUEST TO WAIVE: <br />• 42'-0" FROM NEIGHBORING DRIVEWAY <br />REQUEST TO WAIVE <br />• REDUCE THE REQUIRED NUMBER OF <br />TREES FROM 24 TO 22 <br />RED GOLD BOTTLING CORPORATION PLANNED <br />UNIT DEVELOPMENT, 1ST AMENDMENT <br />LOT 9, BLOCK 1, COLORADO TECHNOLOGICAL CENTER, FIRST FILING, <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO. <br />CASE # PUD-000519-2024 <br />gr9('01 <br />CO <br />CO <br />250 500 1000 <br />PROJECT DESCRIPTION <br />PROJECT <br />LOCATION <br />THE FLEXIBLE OFFICE BUILDING CONTAINS APPROXIMATELY 15,000 SQUARE FEET OF <br />WAREHOUSE AREA AND 2,000 SQUARE FEET OF OFFICE SPACE WITH ADDITIONAL AREA FOR <br />SUPPORT SPACES SUCH AS FUTURE TENANT RESTROOMS AND A WATER ENTRY ROOM <br />THE BUILDING IS 26-8" HIGH (TO TOP OF EXTERIOR WALL) AND THE PRIMARY STRUCTURAL <br />SYSTEM WILL BE CONSTRUCTED OF CONCRETE TILT -UP WALL PANEL CONSTRUCTION AT ALL <br />EXTERIOR WALLS WITH STRUCTURAL STEEL JOISTS SUPPORTING THE ROOF. THE CONCRETE <br />TILT -UP WALL PANELS HAVE BEEN DESIGNED WITH DIFFERENTIATED PATTERNS, FORM LINER, <br />AND ACCENT WALL PAINT COLORS TO PROVIDE THE NECESSARY DESIGN ARTICULATION AS <br />REQUIRED BY THE IDDSG. THE MAIN ALUMINUM STOREFRONT ENTRANCE INTO THE OFFICE <br />AREA IS COVERED BY AN OPEN SUNSHADE STRUCTURE ABOVE AND CLERESTORY PUNCHED <br />OPENINGS ARE LOCATED AT THE PERIMETER OF THE BUILDING AT 14'-6' ABOVE FINISHED <br />FLOOR_ <br />THIS BUILDING IS A CORE & SHELL ONLY, INTERIOR TENANT FINISH -OUT IS NOT IN CONTRACT <br />AND WILL BE PERMITTED SEPARATELY BY TENANT <br />GENERAL NOTES <br />W DILLON RD <br />PROJECT CONTACTS <br />OWNER <br />TWEEDLE DUM, LLC <br />11511 EAST CALEY AVE <br />CENTENNIAL, CO 80111 <br />TVAP@SVDW.COM <br />CONTACT TRAVIS VAP <br />SURVEYOR <br />R&R ENGINEERS -SURVEYORS, INC. <br />1635 W 13TH AVENUE <br />SUITE 310 <br />DENVER, COLORADO 80204 <br />303-753-6730 <br />CONTACT BASIL HANSON <br />ARCHITECT <br />THE BECK GROUP <br />1001 W 1 TTH ST <br />SUITE PL 100 <br />DENVER, CO 80202 <br />720-281-0394 <br />CONTACT_ RAMIRO DIAZ <br />LANDSCAPE <br />OXBOW DESIGN COLLABORATIVE <br />209 KALAMATH ST <br />SUITE 6 <br />DENVER, CO 80223 <br />720-465-6168 <br />CONTACT: JOHN YOUNG <br />CIVIL <br />COLLINS ENGINEERING, INC <br />455 SHERMAN ST <br />SUITE 160 <br />DENVER, CO 80203 <br />720-262-5527 <br />CONTACT: BRYAN FRANTZ <br />LIGHTING <br />AE DESIGN <br />1900 WAZEE STREET <br />SUITE 205 <br />DENVER, CO 80202 <br />303-296-3034 <br />CONTACT: MORIAH HOLLAND <br />BELOW IS A LIST OF WAIVER REQUESTS WITH COMMERCIAL DEVELOPMENT DESIGN STANDARDS AND GUIDELINES. INDUSTRIAL DEVELOPMENT DESIGN STANDARDS AND GUIDELINES, OR LOUISVILLE MUNICIPAL CODE <br />SECTIONS) IDENTIFIED <br />1. THE PROPERTY IS ZONED I - INDUSTRIAL SETBACKS FOR PROPERTY AS AS FOLLOWS: <br />WEST) 15'-0" <br />EAST) 30'-0" <br />SOUTH) 10'-0" <br />NORTH) 10'-0" <br />2. ALL SETBACKS AND LAND USE REQUIREMENTS SHALL CONFIRM TO THE CITY OF LOUISVILLE, COLORADO ZONING AND LAND USE REGULATIONS IN EFFECT AS OF THE DATE OF APPROVAL OF THIS PLANNED UNIT <br />DEVELOPMENT BY THE CITY OF LOUISVILLE, COLORADO. <br />3 EXCEPT AS AMENDED BY THIS FINAL PLANNED UNIT DEVELOPMENT, ALL SIGNS SHALL CONFORM TO THE INDUSTRIAL DEVELOPMENT DESIGN STANDARDS AND GUIDELINES. THESE AMENDMENTS ARE <br />A. TWO FREESTANDING, GROUND MOUNTED DOUBLE FACED SIGNS LOCATED PER THE SITE PLAN SHALL BE PERMITTED. THE DESIGNS FOR THESE SIGNS SHALL BE PER THE DETAIL ON SHEET 7. <br />B. SURFACE MOUNTED BUILDING SIGNS SHALL NOT EXCEED 2 FEET IN HEIGHT BY 20 FEET IN LENGTH EACH WITH A MAXIMUM OF THREE SIGNS. ONE BUILDING SIGN SHALL BE PERMITTED ON THE SOUTH <br />BUILDING ELEVATION ( FACING CTC BOULEVARD), ONE BUILDING SIGN SHALL BE PERMITTED ON THE WEST BUILDING ELEVATION ( FACING CTC BOULEVARD). THE THIRD BUILDING SIGN SHALL BE PERMITTED <br />ON THE EAST BUILDING ELEVATION AFTER CONSTRUCTION OF THE FUTURE ROAD MAXIMUM SURFACE MOUNTED BUILDING SIGNAGE AREA OF 120 SQUARE FEET IN THE AGGREGATE. <br />C, FOR BOTH MULTI TENANT AND SINGLE TENANT OCCUPANCY, THE SURFACE MOUNTED BUILDING SIGN SHALL NOT EXCEED 24 INCHES IN HEIGHT <br />4 THE CITY OF LOUISVILLE IS NOT RESPONSIBLE FOR DAMAGE TO OR REPAIR OF MONUMENT SIGNS DUE TO UTILITY MAINTENANCE. <br />5. THE CITY OF LOUISVILLE IS NOT RESPONSIBLE FOR DAMAGE TO PAVEMENT SURFACES OR LANDSCAPING CAUSED DURING REPAIR OR MAINTENANCE ACTIVITIES OF UTILITIES LOCATED WITHIN PUBLIC UTILITY <br />EASEMENTS_ <br />6 ON -STREET PARKING W1LL NOT BE UTILIZED TO MEET THE PARKING REQUIREMENTS OF THE PROJECT <br />7. ALL ROOF -MOUNTED MECHANICAL, ELECTRICAL, OPTICAL AND ELECTRONIC EQUIPMENT SHALL BE SETA MINIMUM OF 20' FROM THE BUILDING PARAPET, AND IF VISIBLE FROM THE PUBLIC STREET ADJACENT TO <br />THE PROPERTY, SHALL BE PAINTED TO MATCH THE DOMINANT COLOR OF THE BUILDING. <br />8. ALL ROOF -MOUNTED EQUIPMENT SHALL BE EITHER (1) PAINTED A COLOR COMPATIBLE WITH THE DOMINANT BUILDING COLOR, IF THE BUILDING IS SELF-CONTAINED WITHOUT EXPOSED DUCTWORK OR PROCESS <br />PIPING. OR (2) SHALL BE SCREENED IF THE EQUIPMENT DOES NOT MEET THE CRITERIA SPECIFIED IN 1 SCREEN MATERIAL SHALL BE COMPATIBLE WITH MATERIALS AND COLORS UTILIZED ON THE BUILDING <br />9 OWNER WILL ADD ADDITIONAL HANDICAP PARKING SPACES <br />PLANNING COMMISSION CERTIFICATE <br />RECOMMENDED APPROVAL THIS 10 DAY OF April <br />COMMISSION OF THE CITY OF LOUISVILLE, COLORADO. <br />RESOLUTION NO 4 SERIES 2025 <br />CITY COUNCIL CERTIFICATE <br />APPROVED THIS 20 DAY OF <br />LOUISVILLE, COLORADO. <br />RESOLUTION NO. 33 <br />May <br />SERIES 2025 <br />A*e 14- q <br />, 2025 BY THE PLANNING <br />, 2025 BY THE CITY COUNCIL OF THE CITY OF <br />MAYOR CITY CLERK <br />NOTARY PUBLIC BLOCK <br />State of COLORADO <br />County of DENVER <br />Signed before me on JUNE 25TH <br />By KATHLEEN R BARRETT <br />Kathleen R Befreil a rrfwrruU•igr •rs•, <br />rJ�kwn H",1 . <br />(Notary's official signature) <br />THE BECK GROUP <br />(Title of office) <br />03/21/2029 <br />(Commission Expiration) <br />,2025 <br />SEAL <br />KATHLEEN R BARRETT <br />NOTARY PUBLIC <br />STATE OF COLORADO <br />NOTARY ID 20134018001 <br />MY COMMISSION EXPIRES 03/21r2020 <br />DAN: 20134018001-422013 <br />OWNERSHIP SIGNATURE BLOCK <br />The undersigned as the owner of the lands described herein, hereby agrees on behalf of itself, and its heirs, <br />successors and assigns to develop and maintain the properly described hereon in accordance and compliance <br />with this approved plan and the Louisville Municipal Code <br />TWEEDLE DUM, LLC <br />Witness my/our hand(s) and seal(s) this 25 clay of tune 25 <br />ipaciSi by: 20 <br />BY. <br />NOTARY: <br />EF5570EE7DEN67 <br />SHEET INDEX <br />SHEET NUMBER <br />SHEET NAME <br />1 COVER PAGE <br />2 SITE PLAN <br />3 PEDESTRIAN / BICYCLE CIRCULATION PATH <br />4 BUILDING ELEVATIONS <br />5 GRADING PLAN <br />6 UTILITY PLAN <br />7 LANDSCAPE PLAN <br />8 SITE AMENITIES! DETAILS <br />9 PHOTOMETRIC PLAN <br />10 LIGHTING CUT SHEETS <br />11 SURVEY <br />12 FIRE AND LIFE SAFETY PLAN <br />, Travis yap, managing member <br />CURRENT SUBMISSION: PUD AMENDMENT RESUB.#2 <br /># DATE SUBMISSION <br />C 10/20124 PhD AMENDMENT RESUB. #1 <br />D 03/03/25 PUD AMENDMENT RESUB. #2 <br />BECK ARCHITECTURE, LLC <br />1001 17TH STREET <br />SUITE PL100 <br />DENVER CO 80202 <br />PH_ (303) 4669865 <br />WWW.BECKGROUP COM <br />COVER PAGE <br />1 <br />SHEET 1OF12 <br />