04099493 08/25/2025 08.32 AM
<br />RF: $43.00 Page 1 of 4
<br />Electronically recorded in Boulder County Colorado. Recorded as received.
<br />LAND USE SUMMARY
<br />ZONING
<br />TOTAL NO. OF BUILDINGS
<br />BUILDING COVERAGE
<br />PAVEMENT COVERAGE
<br />(PARKING, DRIVES, & WALKS)
<br />NEW TANK COVERAGE
<br />(ON EXISTING PAVEMENT)
<br />LANDSCAPE COVERAGE
<br />TOTAL LOT AREA
<br />FLOOR AREA RATIO
<br />BUILDING HEIGHT
<br />BUILDING AREA:
<br />LOWER LEVEL (FOOTPRINT)
<br />UPPER LEVEL
<br />TOTAL
<br />OVERALL BUILDING
<br />53% OFFICE =
<br />47% R&D =
<br />SPACES PROVIDED:
<br />PUD—I
<br />1
<br />23.8%
<br />44.9%
<br />0.2%
<br />31.1%
<br />92,1 fit S.F.
<br />1:0.341
<br />LOT 13, BLOCK 8
<br />COLORADO TECHNOLOGICAL CENTER, FIRST FILING
<br />PLANNED UNIT DEVELOPMENT, 1ST AMENDMENT
<br />46'-0" (TO ROOF PEAK)
<br />32'-0" (TO TYPICAL PARAPET)
<br />21.300 S.F.
<br />10,130 S.F.
<br />31,430 S.F.
<br />= 31,430 S.F.
<br />16,658 S.F. 0 4:1,000 = 67 SPACES
<br />14,772 S.F. 0 2:1,000 = 28 SPACES
<br />96
<br />AVERAGE PARKING RATIO = 3.05 PER 1,000 S.F.
<br />NOTES
<br />1. DEVELOPMENTS IN THE COLORADO TECHNOLOGICAL CENTER (CTC) ARE ON A SOLE SOURCE
<br />SUPPLY UNE FOR WATER. THOSE LOCATING IN THE PARK ARE SUBJECT TO INTERRUPTIONS OF
<br />SERVICE IN CASE OF EMERGENCY OR UNAVOIDABLE MAINTENANCE ACnVMES THAT AFFECT TPE
<br />SOLE SOURCE FEED TO THE CTC.
<br />2. DEVELOPMENTS 1N THE CTC ARE ON A SOLE SOURCE SUPPLY UNE FOR WATER WHICH MAY, IN
<br />THE NEAR FUTURE, BE INADEQUATE TO MEET DEMAND DURING TIMES OF PEAK USAGE WITHIN THE
<br />, CTC,
<br />3. NO•DECIDUOUS TREES SHALL BE PLANTED VVITIIN-FIVE (5) FEET OR CONIFEROUS TREES WITHIN
<br />TEN (10) FEET OF A PUBLIC UTILITY OR SIDEWALK.
<br />4. THE PROPERTY OWNER SHALL REPLACE Ali. EXISTING CURS AND GUT'I"ER THAT HAS SE TIED
<br />OR IS OTHERWISE DAMAGED ADJACENT T TO THE SITE.
<br />5. TRENCHES WITHIN CHERRY STREET AND ARTHUR AVENUE W1LL NEED TO BE FILLED WITH
<br />PLOWABLE FILL MATERIAL
<br />$ . ALL CONNECTION TO THE EXISTING U lUTIES SHALL BE DONE IN A MANNER TC) WANIMIZE
<br />DISRUPTIONS TO EXISTING USERS.
<br />7. ROOFTOP MECHANICAL ANICAL UNIT CRITERIA-.
<br />a. ROOFTOP MECHANICAL UNITS SHALL BE EFFECTIVELY SCREENED, SETBACK A MINIMUM OF
<br />20-FEET FROM THE ADJACENT BUILDING WALL OR FULLY SCREENED WITH OTTER DESIGN OPTIONS
<br />SUCH AS ROOFTOP PARAPETS.
<br />b. ALL RTUs THAT ARE NOT FULLY SCREENED BY THE BUILDING PARAPET OR
<br />OTHER APPROVED BUILDING ELEMENT SHALL BE PAINTED TO MATCH THE
<br />ADJACENT EXTERIOR BUILDING WALL
<br />• RTUs THAT EXTEND ABOVE THE PARAPET AND ARE NOT ENTIRELY SELF-
<br />CONTAINED, 'CLEAN' BOX UNITS (AS DETERMINED BY STAFF), SHALL BE
<br />SCREENED TO THEIR FULL HEIGHT BY AN ARCHITECTURALLY INTEGRATED
<br />SCREENING MATERIAL TO BE SPECIFIED AND APPROVED ON THE PUD.
<br />d. RTUs THAT EXTEND MORE THAN TWO FEET ABOVE THE PARAPET, REGARDLESS
<br />OF RTU DESIGN OR COLOR, MAY BE REQUIRED TO BE SCREENED, SUBJECT TO STAFF
<br />DETERMINATION BASED ON THE DESIGN OF THE UNIT AND THE POTENTIAL VISUAL EXPOSURE
<br />FROM ADJACENT STREETS AND PRIVATE PROPERTY.
<br />B. ON AN INDIVIDUAL TENANT FINISH OASIS. WHEN OVERHEAD LOADING DOORS ARE DIED
<br />AND DEFERRED PARKING SPACES ARE MADE AVAILABLE. THOSE PARKING SPACES MAY BE
<br />APPLIED TOWARD THE REQUIRED PARKING OF THAT TENANT ONLY TO INCREASE THE AVERAGE
<br />PARKING RATIO FOR THAT SPACE.
<br />9. GROUND SIGN LIGHTING; IS LIMITED TO GROUTED,100-WATT METAL HALIDE LIGHTING •
<br />10. ALL WALL SIGNS SHALL COMPLY WITH BOTH THE STANDARDS AND GUIDELINES IN TINE IDDSG,
<br />SUBJECT TO STAFF REVIEW AND APPROVAL THROUGH A BUILDING PERMIT APPUCAIION.
<br />ti
<br />SITE
<br />J1 ri
<br />A
<br />VICINITY MAP
<br />1*ica sG"LE:
<br />INDEX OF SHEETS
<br />PUD-1
<br />PUD-2
<br />PUD-3
<br />PUD-4
<br />TITLE SHEET
<br />SITE PLAN
<br />ELEVATIONS
<br />LANDSCAPE PLAN
<br />1
<br />1
<br />CB
<br />LEGAL DESCRIPTION
<br />A PART OF SECTION 16, TOWNSHIP 1 SOUTH, RANGE 69 WEST. 6TH
<br />PRINCIPAL MERIDIAN, CITY OF LOUISVILLE, COUNTY OF BOULDER,
<br />STATE OF COLORADO, DESCRIBED AS FOLLOWS:
<br />LOT 13, BLOCK 8, COLORADO TECHNOLOGICAL CENTER, FIRST
<br />FILING, COUNTY OF BOULDER, STATE OF COLORADO
<br />PROJECT DESCRIPTION
<br />THE WORK PROPOSED UNDER THIS PUD AMENDMENT IS FOR THE
<br />INSTALLATION OF AN EXTERIOR LIQUID NITROGEN (LN2) TANK AND
<br />RELATED ITEMS. THOSE ITEMS ARE AN EXTERIOR PAD
<br />SUPPORTING THE TANK, A SCREEN WALL AND FENCE
<br />SURROUNDING THE TANK, PROTECTIVE BOLLARDS SURROUNDING
<br />THE SCREEN WALL AND THE ABOVE GROUND PIPING CONNECTION
<br />FROM THE TANK INTO THE BUILDING. THE TANK IS BEING
<br />LOCATED IN THE PARKING LOT WITHIN THE CLOSEST PROXIMITY
<br />TO THE EXTERIOR WALL WHERE THE EQUIPMENT IS LOCATED
<br />WITHIN THE BUILDING. THIS LOCATION WAS CHOSEN IN ORDER
<br />TO MINIMIZE THE LENGTH OF THE PIPING RUN AND TO NOT
<br />IMPACT ANY IMPERVIOUS SURFACES AND LANDSCAPING. TWO
<br />PARKING SPACES WILL BE VACATED TO ACCOMMODATE THE
<br />TANK AND RELATED ITEMS.
<br />DIRECTOR OF COMMUNITY DEVELOPMENT CERTIFICATE
<br />APPROVED THIS 22nd DAY OF August , 20 25
<br />DIRFfTnR nr (r)MI Al IMITV fJ VI 1 npnAI=MMT OF THE CITY OF
<br />LOL _.
<br />BY:
<br />DIR__. ___
<br />OWNERSHIP SIGNATURE BLOCK
<br />THE UNDERSIGNED AS THE OWNER OF THE LANDS DESCRIBED
<br />HEREIN, HEREBY AGREES ON BEHALF OF ITSELF, AND ITS HEIRS,
<br />SUCCESSORS AND ASSIGNS TO DEVELOP AND MAINTAIN THE
<br />PROPERTY DESCRIBED HEREON IN ACCORDANCE AND COMPLIANCE
<br />WITH THIS APPROVED PLAN AND THE LOUISVILLE MUNICIPAL CODE.
<br />WITNESS MY/OUR HAND(S) AND SEAL(S) THIS J IT. DAY OF , 20 as.
<br />BY:
<br />(SU,SAN J. CHRISMA AGENT FOR OWNER, FCF PROPERTIES, LLC..)
<br />NOTARY
<br />CYNTHIA HOLAPPA
<br />Notary Puajic
<br />Stag of Cuinr:,do
<br />Notary lC N 20224025451
<br />My Commiseiorr Expiros 08-?9-2026
<br />'tip
<br />to
<br />0
<br />0
<br />✓
<br />IL
<br />a Space LN2 Tank
<br />11.1
<br />0)
<br />#-,
<br />c
<br />0)
<br />0
<br />u
<br />0)
<br />0
<br />73
<br />17/.
<br />0
<br />PROJ NO: 23-13
<br />DATE: APRIL 14, 2025
<br />REV: JULY 28, 2025
<br />Copyright e2025 - All rights
<br />reserved RVP Architecture and
<br />Consulting, P.C. All design
<br />drawings and written material
<br />herein may not be used or
<br />duplicated without the written
<br />consent of RVP Architectures and
<br />Consulting. P.C.
<br />COVER SHEET
<br />PUD-1
<br />SHEET1 OF
<br />
|