My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Economic Vitality Committee Agenda and Packet 2025 09 25
PORTAL
>
BOARDS COMMISSIONS COMMITTEES RECORDS (20.000)
>
ECONOMIC VITALITY COMMITTEE
>
2025 Economic Vitality Committee Agendas and Packets
>
Economic Vitality Committee Agenda and Packet 2025 09 25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/18/2025 2:21:41 PM
Creation date
9/18/2025 2:04:40 PM
Metadata
Fields
Template:
City Council Records
Meeting Date
9/25/2025
Doc Type
Boards Commissions Committees Records
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
224
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
adopted the new permit will incorporate all new codes and fees. Permits are <br />automatically extended 180 days from a passed Foundation Inspection and <br />a Passed Framing Inspection. <br />Sec. 15.04.070.- Section 1010.2.4 Amended —Locks and latches. <br />Section 1010.2.4 of the International Building Code is amended to <br />read as follows: <br />1010.2.4. Locks and Latches. Locks and latches shall be permitted <br />to prevent operation of doors where any of the following exist. Except for <br />Group A Occupancies shall only have Panic hardware no deadbolts or other <br />locks are allowed on any doors in group A occupancies. <br />1.Places of detention or restraint. <br />2. In Group 1-1, Condition 2 and Group 1-2 occupancies where <br />the clinical needs of persons receiving care require containment or where <br />persons receiving care pose a security threat, provided that all clinical staff <br />can readily unlock doors at all times, and all such locks are keying to keys <br />carried by all clinical staff at all times or all clinical staff have the codes or <br />other means necessary to operate the locks at all times. <br />3. Locking devices are permitted on doors to balconies, decks or <br />other exterior spaces of 250 square feet (23.23m2) or less, serving a private <br />office space. <br />4. In buildings in Occupancy Groups B, F, M and S, the main <br />door or doors are permitted to be equipped with key -operated locking <br />devices from the egress side provided: <br />4.1. The doors are the main exterior doors to the building, <br />or the doors are the main doors to the tenant space. <br />4.2. The locking device is readily distinguishable as locked. <br />4.3. A readily visible durable sign is posted on the egress <br />side on or adjacent to the door stating: THIS DOOR TO REMAIN <br />UNLOCKED WHEN THIS SPACE IS OCCUPIED. The sign shall be in <br />letters one inch (25 mm) high on a contrasting background. <br />4.4. The use of the key -operated locking device is <br />revocable by the Fire Code Official for due cause. <br />5. Manual bolts, automatic flush bolts and constant latching bolts <br />on the inactive leaf of a pair of doors in accordance with Table 1010.2.4, <br />4 <br />Agenda Packet P. 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.