Laserfiche WebLink
PAGE THREE <br />SUBJECT: RESOLUTION NO. 54 , SERIES 2011 — A REQUEST TO APPROVE A FINAL <br />PLANNED UNIT DEVELOPMENT (PUD) PLAN AND FINAL SUBDIVISION <br />PLAT FOR THE DEVELOPMENT OF 19.73 ACRES WITH TWO (2) BUILDINGS <br />(313,290 SF OF BUILDING AREA) IN THE COLORADO TECHNOLOGICAL <br />CENTER SUBDIVISION, FILING 2 <br />DATE: SEPTEMBER 6, 2011 <br />manufacturing /warehousing space along with a mezzanine for office space. <br />Due to the length of the structure, the building has been designed with articulations along the <br />street facing facades to provide visual relief and landscaping consistent with the IDDSG. The <br />pedestrian components of the structure are designed with glazing. The structure is tan and <br />beige on the horizontal step outs with glazing details. A painted steel canopy will accentuate <br />each of the building entrances. <br />The backside of the two structures face each other and the north side of the buildings will <br />provide a landscaped screening wall to hide the view to the loading area from Boxelder Street. <br />Both structures will be built during one phase, eliminating the need for temporary screening. <br />Circulation <br />The proposed site plan provides five (5) access driveways for the property: two (2) on CTC <br />Boulevard; two (2) on South 104th Street; and, one (1) on Boxelder Street. The IDDSG allows <br />only three (3) driveways for properties larger than 5 acres. In this instance, because the <br />property is 19.73 acres in size, the applicant is requesting a waiver to access requirements to <br />allow for two (2) additional driveway accesses. <br />Staff is supportive of this request because if each lot were to develop separately the proposed <br />access points would meet the IDDSG requirements as follows: <br />Lot.8 (2.7 acres) — 2 access points <br />Lot 9 (2.68 acres) — 2 access points <br />Lot 10 (3.66 acres) — 2 access points <br />Lot 13 (7 acres) — 3 access points <br />Lot 14 (3.63 acres) — 2 access points <br />The project provides the required sidewalks around the buildings as well as connection to <br />Boxelder Street. However, in order to meet the American with Disability Act (ADA) and the <br />(IDDSG), the project is required to provide a pedestrian connection to the existing sidewalk <br />along South 1041 Street. Staff recommends the applicant provide a sidewalk connection from <br />the existing sidewalk along South 104th Avenue onto the property. <br />Parking <br />Parking for the development will be constructed around the perimeter of the building. <br />According to the IDDSG, the IDDSG states, the parking proposed for this development is 368 <br />spaces, which provides a parking ratio of 1.17 spaces / 1,000 SF. According to the IDDSG, <br />this parking ratio would be suitable for "Warehouse Space ". The Allen Company is considered <br />47 <br />