Laserfiche WebLink
<br />B. Table No. 502.2.1 and Table No. 502.3.1 of the <br />Model Energy Code shall be completed by the <br />addition of the following U, R, OTTV, and SF values <br />to said tables as follows: <br /> <br /> TABLE NO. 502.2.1 <br /> TYPE A-I TYPE A-2 <br />ELEMENT MODE BUILDINGS BUILDINGS <br />Walls Heating or Cooling Uo = 0.13 Uo = 0.29 <br />Roof/Ceiling Heating or Cooling Uo = 0.026 Uo = 0.026 <br />Floors over <br />unheated spaces Heating or Cooling U = 0.05 U = 0.05 <br />0 0 <br />Heated slab on <br />grade Heating R = 10 R = 10 <br />Unheated slab on <br />grade Heating R = 10 R = 10 <br />Basement wall Heating or Cooling Uo = 0.096 Uo = 0.096 <br />Crawl wall Heating or Cooling Uo = 0.06 Uo = 0.06 <br /> <br /> TABLE NO. 502.3.1 <br /> ELEMENT MODE VALUE <br /> Heating Uo = 0.27 <br /> 3 stories Cooling OTTVw = 33.4 <br /> or <br /> less Cooling SF = 127 <br />Walls Heating Uo = 0.33 <br /> Over 3 stories Cooling OTTV w = 33.4 <br /> Cooling SF = 127 <br /> Heating/Cooling Uo = 0.076 <br />Roof/Ceiling Cooling OTTV r = 8.50 <br />Floors over unheated <br />spaces Heating/Cooling U = 0.05 <br /> 0 <br />Heated slab on grade Heating/Cooling R = 7 <br />Unheated slab on grade Heating/Cooling R = 5 <br />Basement wall Heating or Cooling U value = 0.096 <br />Crawl wall Heating or Cooling U value = 0.06 <br /> <br />7 <br />