Laserfiche WebLink
Hole by Hole Analysis <br />!_bl v COLA ,L <br />Louisville. CO <br />Hole 13 <br />Recorrstruo'i and elevate tees <br />Strip sod elevate and reshape tee <br />surfae, acid mnlzone mix and re- grass. <br />Back The 25 <br />MIddie Back Tee: 40' x 79' <br />Sod; 33.500 sf <br />landregrass Strip aod, level 2,215 sf tee <br />'and regress <br />itrap sod. level 2.0411 sf tee 1 <br />and regress <br />;i / <br />/ <br />Convert 45,500 sf of out -of -play <br />area to tow - maintenance turf <br />Construct rrew 25' x 30' <br />forward fee <br />rReteca,tc and elevate bunker to mitigate fairy floodingt <br />Remove contaminated sand, fireplace drainage <br />tlnrltiding "earl[' d'ralns arid sumps. restore edges, adld <br />row and and regress aurmunda. <br />Bunker. 2,070 sf <br />Extacral tile: 1001f <br />Sods 12,000 :.f <br />Topsoil: 20 Cy <br />Rebuild bunker. <br />Remove contaminated sand, replace <br />drainage (including 'exit" drains and <br />Bumps, restore edges, add new sand <br />and regress surrounds. <br />B unker. 1,500 sf <br />Eternal tile: 100 If <br />Sod; 4.350 sf <br />1 catch basin with 200 If <br />Widen cart path at the green <br />Cart Path: 4' x 50' <br />Curbing: 70 If <br />Repair 4.455 of green: <br />S trip acrd, remove sat, <br />remove °colter darn" add <br />greentdmok, regradle and <br />regress <br />13 of,19 <br />f / Rebuild bunker <br />1 <br />Repair areas damaged by flooding: <br />S1np Sod, refr+ave silt, regrada far positive <br />surface drainage. and regress f- 2.000 af} <br />Widen cart path at tee <br />Cart Path: 4' x 50' <br />Curbing: 70 If <br />Repair areas damaged by t1aodlny. <br />Strap sod, T move sia, regrede for positive <br />surface drainage, and regress (- 47,000 sf) <br />[R: 11900 sf] <br />Create collection areas, add catch basins <br />and pipe to improve poor drainage area. <br />Use soil to elevate tees. <br />Catch Basins: 2 ea <br />Draintile: 230 If <br />Create collection area, add catch basin <br />and pipe to improve poor drainage area. <br />Use soil to elevate tees. <br />Catch Basins: 1 ea <br />Draintite: 170 sf <br />Remove contaminated sand, replace <br />drainage (including 'ex11" drains and <br />sumps. restore edges,, add new <br />sand and regress surrconda. <br />Bunker 1.F345 sf <br />External tile; 50 ti <br />Sod: 2,150 sf <br />• <br />KEY <br />Storm Damage Improvement <br />Golf Course Improvement <br />Recommendations <br />Date: January 7, 2014 (Rev 1/14/14) <br />0 100 200 300 FT <br />21 <br />