My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Business Center at CTC Lot 1 Block 1 Sounds True Inc PUD Mylar
PORTAL
>
RECORDED PLATS (Mylars) and CITY MAPS
>
PUD (Planned Unit Developments)
>
C
>
CTC - Business Center at
>
Business Center at CTC Lot 1 Block 1 Sounds True Inc PUD Mylar
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/5/2018 11:10:17 AM
Creation date
3/10/2017 3:26:37 PM
Metadata
Fields
Template:
CITYWIDE
Also Known As (aka)
Sounds True Inc
Doc Type
Mylar
Subdivision Name
Business Center at CTC
Parcel Identification Number
157516010001
Record Series Code
40.180
Record Series Name
Maps Drawings Plats Plans
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
0 <br />I co <br />0 <br />Business Center at CTC <br />DRAWING NUMBER <br />� <br />co <br />z <br />2 <br />0 <br />1 <br />1 <br />... <br />jg— <br />, <br />= <br />TRENCH AND PATCH <br />FLOWABLE FILL MATERIAL <br />REQUIRED TO BACK OF WALK <br />STORM /WATER CROSSING DATA <br />BOTTOM 18" ST/L: ±5295.55 <br />TOP OF 1" W: ±5291.55 <br />\ ASPHALT <br />\ PATCH <br />PROPOSED <br />ONE—STORY BUILDING <br />15,000 S.F. € <br />3.00 <br />SERVICE INVERT <br />ELEV: 5296.70 <br />SEE PLUMBING PLANS <br />FOR CLEANOUT AND <br />CONTINUATION <br />F.F.E.= 5303.2 <br />2.5.9 <br />541' <br />0_503,4, ..r)3. <br />\ suOP * <br />\ VERTICAL <br />\ ANGLE POINT <br />INV: 5293.11 <br />1 <br />WET TAP TEE <br />INSTALL 6" C.V. (W) <br />INSTALL THRUST BLOCK <br />INSTALL 6" CL52 D.I.P. <br />44 <br />DATE BY <br />co <br />S— , <br />7:3 <br />co.%) <br />INSTALL TAP SADDLE <br />INSTALL CORP STOP <br />INSTALL 1" TYPE K COPPER <br />TAP EXISTING MAIN <br />CUT IN CONNECTION <br />DEEP TRENCH SEWER SERVICE <br />MAIN INVERT: 5288.19 <br />STORM /SARITARY CROSSING DATA <br />BOTTOM 18" ST/L: ±5295.46 <br />TOP OF 4" S/S: ±5294.30 <br />0 <br />1 <br />FIRE HYDRANT <br />AND THRUST BLOCK <br />FLANGE ELEV: 5302.75 <br />1 <br />DETENTION <br />POND LIMITS <br />_ <br />43 ,E <br />"-'411ftriveralosA <br />193.64, <br />• <br />\ \ <br />REVISION <br />WET TAP SWIVEL TEE 12"x6" <br />INSTALL KICK BLOCK <br />12" G.V.(E) <br />6" G.V.(N) <br />APP V <br />DATE <br />_ <br />2 2 6.96' <br />Design 18 Drown a8 <br />Checked ,./L8 Checked ..18 <br />Date 10/04/04 <br />glob No. 1183 <br />D— 11811 <br />918 ELDORADO LANE <br />LOUISVILLE, COLORADO 80027 <br />PHONE: 303.604.1634 <br />FAX: 303.604.1674 <br />R=23.00' <br />L=45.56' <br />Tan=35.08' <br />Delta=113°29'57" <br />N43°08'19"E 38.47' <br />AMMO 0111••••• <br />TACK COAT <br />EXISTING ASPHALT <br />6' MIN, <br />ASPHALT PATCH OR <br />COMPLETE FULL <br />DEPTH ASPHALT <br />PATCH OF EXISTING <br />STREET SECTION. <br />INSTALL ASPHALT <br />IN LIFTS AND COMPACT <br />TO 95% MIN. <br />UT(L(TY PLAN LEGEND <br />EX. CURB & GUTTER <br />CURB AND GUTTER <br />CONCRETE PAVEMENT <br />RETAINING WALL <br />EX. STORMLINE <br />PROP. STORMLINE <br />STD FH <br />ASSEMBLY <br />EXIST. WATERLINE <br />EXIST. SEWERLINE <br />PROPOSED WATER w <br />PROPOSED SEWER ss <br />EXISTING WATER <br />EXISTING SEWER <br />EXISTING GAS <br />EXISTING HP GAS <br />EXISTING ELECTRIC <br />12' PETRO TACK <br />OR APPROVED EQUAL <br />NEW ASPHALT <br />PATCH <br />NOTES: <br />GATE VALVE <br />/1 <br />MANHOLE <br />METER <br />a -- <br />CO CLEANOUT <br />UNIFORM LINE CUT <br />ASPHALT <br />/3"A,V,1 <br />95% <br />COMPACTED <br />BACKFILL.7 <br />FRENCH WIDTHH <br />SEE TABLE <br />COVER VARIES <br />I ' <br />MILL 12° <br />EXISTING ASPHALT <br />MATCH EXISTING ASPHALT <br />DEPTH WITH ASPHALT <br />PATCH TO LIMITS OF <br />PETRO TACK <br />ALL TRENCH EXCAVATIONS <br />IN ARTHUR AVENUE WILL NEED <br />TO BE BACKFILLED WITH <br />FLOWABLE FILL MATERIAL <br />TYPICAL TRENCH PATCH SECTION <br />1. TRENCH TO BE SLOPED OR BRACED AND SHORED AS REQUIRED. <br />PIPE DIAMETER <br />MINIMUM WIDTH <br />MAXIMUM WIDTH <br />REVISIONS <br />DATE BY <br />WTR1 <br />1*=20` <br />20 0 20 <br />6" 8" 12" <br />1'-10* 2'-0" 2'-4" <br />2'-6" 2'-8" 3'-0" <br />CITY OF LOUISVILLE DRAWN BY: DATE <br />M.L. JAN. 94 <br />ENGINEERING DEPARTMENT APPROVED DATE <br />BY: D.B. JAN, 94 <br />TYPICAL TRENCH PATCH SECTION SHEET_14 _OF_81 _ <br />40 <br />SCALE FEET <br />(WHEN PLOTTED ON 24"x36") <br />PITIAlegelVC <br />Civil Engineers <br />LOT 1, <br />NE CORNER <br />CITY OF <br />GENERAL NOTES: <br />I. ALL FITTINGS AND D.I. PIPE TO BE <br />WRAPPED IN POLYETHYLENE AND TAPED <br />2. 5' UNOBSTRUCTED AREA AROUND <br />HYDRANT. <br />3. 6 SACK CONCRETE KICKBLOCK <br />4. ALL FITTINGS SHALL BE RESTRAINED <br />JOINT OR MEGALUG. <br />MIN, 4,5' OF COVER -1111104- <br />11 <br />.111 - <br />SWIVEL TEE <br />TRRUST BLOCK <br />6" VALVE BOX <br />6' GATE VALVE <br />DRAIN HOLE MUST <br />BE KEPT CLEAR <br />THRUST - <br />BLOCK <br />12" <br />ELlz <br />12' MIN. <br />A <br />6' LATERAL (LATERAL <br />MUST BE DUCTILE IRON) <br />FIRE <br />HYDRANT <br />RISER <br />1/3 CUBIC YARD <br />3/4' OR 1 1/2" <br />WASHED ROCK <br />SECTION CONCRETE BLOCK HYDRANT SUPPORT <br />REVISIONS El <br />M CITY OF LOUISVILLE <br />DATE BY <br />ENGINEERING DEPARTMENT <br />.k4 FIHY <br />FIRE HYDRANT INSTALLATION <br />P=1 <br />-.0 <br />PROPERTY LINE <br />1/3 CUBIC <br />YARD 3/4° <br />OR 1 1/2" <br />WASHED <br />ROCK <br />BOND <br />BREAKER <br />THRUST <br />BLOCK <br />SECTION A <br />DRAWN BY: DATE <br />M.L. JAN. 94 <br />APPROVED DATE <br />BY:D.B. JAN. 94 <br />A <br />UNDISTURBED <br />SOIL <br />+ON- WIDTH OF TRENCH OR 3' <br />SHEET 37 OF81 <br />45° ANGLE <br />SANITARY SEWER MAIN <br />CONCRETE <br />SECTION <br />NOTES! <br />GRANULAR BEDDING <br />6' BELOW PIPE <br />TO 12" O.T.P. <br />SEWER SERVICE <br />CONNECTION AT <br />PROPERTY LINE, <br />CALDER COUPLER <br />OR APPROVED EQUAL <br />1. BELLS SHALL NOT TOUCH THE SIDES OR BOTTOM OF THE BELL HOLE. <br />2, THE BARREL SECTION SHALL BE SUPPORTED THROUGHOUT ITS LENGTH, <br />3. SERVICE TAPS SHALL BE IN LINE WYES ON NEW MAINS, AND MACHINE <br />TAPPED AND WYE SADDLE ON EXISTING MAINS. HAND TAPS SHALL NOT <br />BE ALLOWED, <br />4. THE CURB SHALL BE MARKED WITH "S" OR 'X' WHERE THE SEWER SERVICE <br />LINE CROSSES THE CURB WHERE APPLICABLE. <br />5. ALL JOINTS SHALL BE WATER TIGHT. <br />6, ALL SERVICE LINES SHALL BE 4" UNLESS OTHERWISE APPROVED. <br />7. INSPECTION REQUIRED PRIOR TO BACKFILL. <br />REVISIONS LS CITY OF LOUISVILLE <br />DATE BY ENGINEERING DEPARTMENT <br />ALLEYS <br />1 <br />DEEP TRENCH <br />SEWER SERVICE REPLACEMENT <br />BUILDING DATA — FIRE FLOW <br />GROSS SQUARE FOOTAGE: 14,975 <br />CONSTRUCTION TYPE: III—B <br />REQUIRED FLOW: 2,000 gpm <br />REDUCED FLOW: 1,500 gpm (2003 IFC) <br />HYDRANTS: 1 (EXISTING) <br />MASTER UTILITY PLAN <br />BLOCK 1, BUSINESS CENTER AT CTC <br />OF ARTHUR AVENUE AND CHERRY ST <br />LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO <br />REET <br />DRAWN BY: DATE <br />M.L. JAN. 94 <br />APPROVED DATE <br />BY: D.B. JAN. 94 <br />SHEET 9 OF81 oe <br />• <br />CITY OF LOUISVILLE <br />APPROVAL <br />By <br />Date: <br />Document Approval Expires: <br />This document was reviewed for conformance with City of <br />Louisville Design and Construction Standards. City approval <br />does not relieve owners, design engineer, or controactor of <br />responsibility to correct errors or ommissioins relating to <br />this document. <br />SHEET <br />1 <br />OF 1 SHEETS <br />®COPYRIGHT All ENGINEERING CONSULTANTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.