My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Business Center at CTC Lot 1 Block 1 Sounds True Inc PUD Mylar
PORTAL
>
RECORDED PLATS (Mylars) and CITY MAPS
>
PUD (Planned Unit Developments)
>
C
>
CTC - Business Center at
>
Business Center at CTC Lot 1 Block 1 Sounds True Inc PUD Mylar
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/5/2018 11:10:17 AM
Creation date
3/10/2017 3:26:37 PM
Metadata
Fields
Template:
CITYWIDE
Also Known As (aka)
Sounds True Inc
Doc Type
Mylar
Subdivision Name
Business Center at CTC
Parcel Identification Number
157516010001
Record Series Code
40.180
Record Series Name
Maps Drawings Plats Plans
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LOT 1, BLOCK 1 <br />0 <br />w <br />' `z <br />0 2-S <br />ti ui10 <br />Z� <br />•!i ib <br />m <br />ooh <br />a. <br />8 <br />1� I <br />Sounds True, <br />/1 <br />f <br />GRANULAR <br />BEDDING <br />MATERIAL <br />NOTES: <br />1P" <br />SELECT BACKFILg p5% MIN, <br />STORM SEWER <br />GRANULAR BEDDING SECTION <br />1, DEPTH OF BEDDING BELOW PIPE' <br />D d(MIN.) <br />27' & SMALLER 3° <br />30' to 60' 4' <br />66° & LARGER 6' <br />2, GRANULAR BEDDING SHALL BE PLACED FROM THE TRENCH BOTTOM TO <br />THE HORIZONTAL CENTERLINE OF THE PIPE. <br />3, SELECT BACKFILL FROM THE CENTERLINE TO 12' ABOVE THE PIPE <br />SHALL BE PLACED IN 6' LIFTS AND HAND COMPACTED TO 95%. <br />REVISIONSL CITY OF LOUISVILL <br />DATE BY ENGINEERING DEPARTMENT <br />STORM SEWER <br />+ STRM1 TYPICAL TRENCH SECTION <br />WALK <br />6' <br />1112 <br />MAX. <br />DRAWN BY: DATE <br />M.L. JAN. 94 <br />APPROVED DATE <br />BY: D.B. JAN. 94 <br />SHEET_ 45_OF_81_ <br />_ 112 <br />MAX. <br />4' <br />MID -BLOCK PLAN <br />DEPRESS <br />BACK OF <br />RAMP * <br />ELEVATION <br />* 1-1/2"–VER11CAL CURB <br />1" CURBWALK <br />6' <br />REVISIONSIMCITY OF LOUISVILLE <br />DATE BY ENGINEERING DEPARTMENT <br />STR20 <br />DATE BY <br />HANDICAPPED MID—BLOCK RAMP <br />REVISION <br />WALK <br />p <br />PLAN VIEW <br />TABLE -1 <br />TYPE OF LENGTH OF <br />WALK PLATE <br />4' ATT. 4'-4' <br />8' ATT. 8'-4' <br />4' BET. VARIES <br />B <br />L_ <br />5' MIN. <br />-EXPANSION JOINT <br />--- 5' MIN. --- <br />B <br />lib'SEE SHEET 69 OF 81 <br />6' MIN. <br />FOR SECTIONS <br />ISOMETRIC VIEW <br />REVISIONS`CITY OF LOUISVILLE <br />DATE BY ENGINEERING DEPARTMENT <br />whit STRIO <br />1 / <br />DRAWN BY: DATE <br />M.L. JAN. 94 <br />APPROVED DATE <br />BY: D.B. JAN. 94 <br />SHEET_76 _OF_81 _ <br />SIDEWALK CHASE <br />VERTICAL <br />CURB & GUTTER <br />1/2"i <br />MEDIAN <br />CURB & GUTTER } <br />6" <br />TYPICAL <br />CURB & GUTTER <br />AT DRIVEWAY <br />NOTE: <br />6" <br />2"i <br />DRAWN BY: DATE <br />M.L. JAN. 94 <br />APPROVED DATE <br />BY: D.B. JAN. 94 <br />SHEET_C$_OF_$1 _ <br />1 1/2"-- — <br />2'– O" <br />1 1 /2"R.-- <br />1 1/2" -y <br />._ <br />1'-0"--- <br />1 1/2"R.----- <br />1 <br />/2"R.--...1 1 /2"R. \ /- <br />2-0" <br />1 1 /2"R.--iN / <br />-- 4 1/2" <br />1 1/2"R. <br />�6. <br />t <br />12" <br />-- 4 1/2" <br />6" <br />12", <br />SEE NOTE 1. <br />1. AT THE LOW POINT(S) OF EACH MEDIAN, A 1"x4" BOARD SHALL BE USED TO <br />FORM A SLOT IN THE MEDIAN C. & G. THROUGH WHICH DRAINAGE CAN SEEP. <br />REVISIONS 1111 <br />MCITY OF LOUISVILLE <br />DATE BY ENGINEERING DEPARTMENT <br />STR9 <br />APPY DATE <br />STREET CURB & GUTTER <br />Design ✓L8 Drawn 18 <br />Checked JIB Checked ✓L8 <br />Date 10/04/04 <br />Job No. 1183 <br />0— 11831 <br />DRAWN BY: DATE <br />M.L. JAN. 94 <br />APPROVED DATE <br />BY:D.B. JAN. 94 <br />SH EET_6.Z_OF_$1__ J <br />6' VERT. C. & G.1 <br />1 1/2' <br />6'-1 <br />6' VERT. C. & G, <br />LB. <br />-- �1 <br />1/2' <br />[ 6° <br />2.0% <br />LENGTH (SEE TABLE SHEET 68) <br />MIN. 1.0% <br />SECTION A -A <br />FLOW FROM GUTTER <br />2.0% <br />2.0% <br />SLOPE <br />VARIES <br />SLOPE <br />_ VARIES <br />NO, 3 REBAR 6' LONG WELDED <br />TO PLATE AT 18' O.C. EACH <br />SIDE (1/2" ANCHOR BOLT MAY <br />BE USED.) <br />EXP. JOINT <br />E MIN. <br />SECTION A -A <br />FLOW TO GUTTER <br />b2' <br />NON–SLIP RAISED PATTERN <br />STEEL PLATE FOR THICK– <br />NESS, T.P., SEE CHART. <br />vY ///iii////////ii,r <br />J 1 3/8' <br />E=8' WHEN FLOW IS FROM GUTTER <br />6° WHEN FLOW IS TO GUTTER <br />EXP. JOINT <br />VARIES <br />WO <br />4' MIN. <br />2 E PLUS WIDTH OF OPENING <br />SECTION B -B <br />12' MIN. <br />MULTIPLE CHASE <br />WHEN OPENINGS ARE LARGER THAN 18' <br />REVISIONS az CITY OF LOUISVILLE <br />DATE BY ENGINEERING DEPARTMENT <br />2-95 M.L. <br />STR11 <br />SIDEWALK CHASE <br />CAP STONE —\ <br />ELEV PER PLAN <br />POND <br />FINISH. GRADE <br />PER PLAN <br />8" THICK REIFORCED <br />CONCRETE FOUNDATION <br />#4 ®12" EACH WAY <br />EXP. JOINT <br />W.O. T.P <br />WIDTH THICKNESS <br />OF OPENING OF PLATE <br />6" 3/8' <br />6"-12" 1/2' <br />12'-18' MAX. 9/16' <br />�I 4 <br />DRAWN BY: DATE <br />M.L. JAN. 94 <br />APPROVED DATE <br />BY:D.B. JAN. 94 <br />SHEET_ 69OF81_ <br />STREET <br />UNIT CORE FILL <br />(3/4" CRUSHED ROCK <br />OR STONE) <br />PERFORATED DRAIN <br />DISCHARGE INTO STORM <br />OUTLET <br />BASE LEVELING PAD NOTES: <br />1. THE LEVELING PAD IS TO BE CONSTRUCTED <br />OF CRUSHED STONE OR 2,000 PSI± <br />UNREINFORCED CONCRETE. <br />2. THE BASE FOUNDATION IS TO BE APPROVED <br />BY THE SITE GEOTECHNICAL ENGINEER PRIOR <br />TO PLACEMENT OF THE LEVELING PAD. <br />STANDARD UNIT <br />WIDTH: 18" <br />*DEPTH: 21" <br />HEIGHT: 8" <br />*WEIGHT: 115 LBS <br />SLOPE CUT <br />REVISIONS <br />DATE BY <br />JUN. 01 M.T.L. <br />STR13 <br />8" CAP UNIT <br />KEYSTONE STANDARD UNIT <br />FINISHED GRADE <br />LI <br />w <br />0 <br />z <br />SEE NOTES ON SHEET 70 OF81 <br />L CITY OF LOUISVILL <br />ENGINEERING DEPARTMENT <br />STANDARD RAMP DRIVE <br />64 <br />UNREINFORCED CONCRETE OR <br />CRUSHED STONE LEVELING PAD <br />MINI CAP UNIT <br />WIDTH: 18" <br />*DEPTH: 10" <br />HEIGHT: 4" <br />*WEIGHT: 45 LBS <br />CRUSHED ROCK OR <br />UNREINFORCED CONCRETE <br />LEVELING PAD <br />STANDARD UNIT/BASE PAD ISOMETRIC VIEW <br />MODULAR BLOCK WALL <br />12' GRID LENGTH <br />REINFORCED <br />BACKFILLL <br />UNIT CORE FILL <br />(3/4" CRUSHED <br />ROCK OR STONE) <br />PERFORATED DRAIN PIPE <br />DAYLIGHT ON SITE <br />NON -DETENTION POND WALE NOTES: <br />1. INSTALL GEO GRID BEGINNING AT 1' ABOVE BASE AT <br />2' INTERVALS TO WITHIN 1' OF TOP OF WALL <br />2. OBTAIN APPROVAL FROM ARCHITECT OR OWNER FOR TYPE <br />AND COLOR OF MODULAR UNIT <br />N <br />0W <br />W J <br />m0 <br />z r i— <br />wcaW <br />W Z m <br />(n Q V) <br />MONOLITHIC POUR <br />DRAWN BY: DATE <br />M.L. JAN. 94 <br />APPROVED DATE <br />BY:D.B. JAN. 94 <br />SHEET_71 _OF_81 _ <br />3. ALL CAP STONES SHALL BE SECURELY FASTENED TO THE WALL UNIT <br />USING MANUFACTURERS APPROVED ADHESIVE <br />4. PERFORATED DRAIN PIPE SHALL BE 4" EXTERIOR CORRUGATED HDPE <br />WITH FABRIC WRAP INSTALLED BY MANUFACTURER <br />SECTION A -A <br />APPROXIMATE <br />EXCAVATION LINE <br />5. ALL BACKFILL, OTHER THAN THE CORE FILL ZONE BEHIND THE WALL <br />SHALL BE ON SITE MATERIALS FREE OF ORGANICS OR STONES <br />LARGER THAN 2" DIAMETER. COMPACTION SHALL BE IN ACCORDANCE <br />WITH THE SOILS REPORT FOR THE SITE. <br />GENERAL NOTES: <br />1. STONE COLOR TO BE SELECTED BY OWNER OR ARCHITECT. <br />2. ALTERNATE VERTICAL JOINTS BY OFFSETTING BLOCK 1/2 OF LOWER <br />BLOCK. <br />3. PROVIDE EXPANSION JOINTS EVERY 25' MAXIMUM AND AT ANGLE <br />POINTS. <br />4. CAP STONE SHALL BE 1" WIDER THAN MASONRY STONE. ELEVATION <br />SHOWN ON PLANS INDICATES TOP OF CAPSTONE ELEVATION. <br />5. GROUT EVERY CELL AND PROVIDE #4 REBAR VERTICALLY TO <br />BOTTOM OF CAP STONE. TIE REBAR INTO BASE STEEL. <br />6. SYSTEM SHALL BE ENGINEERED BY SUPPLIER OR THEIR AGENT FOR <br />THE GIVEN DESIGN PARAMETERS AND SOIL CONDITIONS. <br />7. USE GEOWESTERN BY AMA STONE, LITTLETON COLORADO, OR <br />APPROVED EQUAL. <br />918 ELDORADO LANE <br />LOUISVILLE, COLORADO 80027 <br />PHONE: 303.604.1634 <br />FAX: 303.604.1674 <br />Civil Engineers <br />1 <br />TOP OF BANK <br />AS NOTED ON PLAN <br />MAX WS PER PLAN <br />1 L` <br />4 (MIN) <br />BOTTOM OF SLOPE / '— FLOW LINE OR <br />AS NOTED ON PLAN <br />TRICKLE CHANNEL <br />GRASS LINED POND <br />WITH LANDSCAPE FEATURES <br />GENERAL POND MINIMUM SECTION <br />DETENTION POND GRADING <br />DETAILS <br />LOT 1, BLOCK 1, BUSINESS CENTER AT CTC <br />NE CORNER OF ARTHUR AVENUE AND CHERRY STREET <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO <br />11 <br />4 (MIN) <br />CITY OF LOUISVILLE <br />APPROVAL <br />By <br />Date: <br />Document Approval Expires: <br />This document was reviewed for conformance with City of <br />Louisville Design and Construction Standards. City approval <br />does not relieve owners, design engineer, or controactor of <br />responsibility to correct errors or ommissioins relating to <br />this document. <br />SHEET <br />DET 1 <br />OF 1 SHEETS <br />©COPYRIGHT JIB ENGINEERING CONSULTANTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.