Fire Station 2 Amendment 2 PUD SRU Mylar
PORTAL
>
RECORDED PLATS (Mylars) and CITY MAPS
>
PUD (Planned Unit Developments)
>
F
>
Fire Station 2 Amendment 2 PUD SRU Mylar
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2019 1:55:44 PM
Creation date
3/8/2018 11:49:24 AM
Metadata
Fields
Template:
CITYWIDE
Doc Type
Mylar
Ord/Res - Year
2018
Ord/Res - Number
02
Recordation Number
3643182
Subdivision Name
Fire Station 2
Parcel Identification Number
157507301001
Cross-Reference
PC Res 2017-24
Record Series Code
40.180
Record Series Name
Maps Drawings Plats Plans
Quality Check
3/8/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Boulder County, CO 03643182 <br />EXISTING FOUNDATION WALL AND <br />BASEMENT AGGE55 STAIRS TO <br />REMAIN - INSTAI 1 NEW ROOF <br />OVER STAIR SECTION <br />NEW GONGRETE STEPS WITH - <br />PAINTED STEEL GUARDRAIL 8 <br />HANDRAIL <br />EXISTING TRANSFORMER TO <br />REMAIN <br />EXISTING POLE MOUNTED LIGHT <br />FIXTURE TO REMAIN <br />EXISTING GURB TO REMAIN <br />REMOVE EXISTING AG <br />CONDENSING UNIT <br />AND CONCRETE PAD <br />GENERATOR <br />NEW ROOF OVER <br />EGRESS DOOR, <br />EXISTING CONCRETE <br />SLAB ON GRADE <br />EXISTING <br />BUILDING <br />NEW VESTIBULE <br />ADDITION <br />NEW EGRESS <br />STAIR ADDITION <br />DEMO EXISTING AG UNIT <br />AND GONGRETE PAD <br />EXISTING WINDOW <br />WELL <br />REMOVE PORTION OF GONG PATIO <br />STONE MIXGH <br />❑ <br />REMOVE EXISTING AG <br />CONDENSING UNIT <br />AND CONCRETE PAD <br />EXISTING CONCRETE RETAINING <br />WALL TO REMAIN <br />\„I <br />DEMOLISH EXISTING <br />WAVING, LANDSCAPING, <br />AND OVERHANGING ROOF <br />TRUGTURE 'ND POSTS /\ <br />NEW WALL MOUNTED <br />LIGHT FIXTURE - RE: <br />PHOTOMETRIC PLAN <br />DEMO EXISTING WALL <br />MOUNTED LIGHT <br />FIXTURE <br />NEW WALL MOUNTED <br />LIGHT FIXTURE - RE: <br />PHOTOMETRIC PLAN <br />\,/ <br />f� NEN-EN1R i EMO PORTION OF <br />EXISTING CURB <br />SLOPE UP 2” <br />STONE MULCH <br />EXISTING CONCRETE SIDEWALK <br />IBENGH I <br />AnkL <br />'1 <br />r O' <br />GONGRETE PATIO TO REMAIN <br />EXISTING TIMBER RETAINING <br />WALL TO REMAIN <br />Large Scale Site & <br />Landscape Plan <br />- 1_0" <br />0111111 <br />IMMO <br />IRRIGATED TURF <br />NEW GMU TRASH ENCLOSURE WITH <br />GORRUGATED METAL GATES - <br />MATGH BUILDING EXTERIOR <br />FINISHES <br />PROPERTY LINE <br />GANG WALKWAY <br />G POLE EXISTING FLAGPOLE AND <br />UPLIGHT TO REMAIN <br />2 <br />SLOPE UP 4" <br />DEMO EXISTING TRASH <br />ENGLOSU <br />STONE MULCH <br />MINIM <br />EXISTING PARKING <br />STRIPING TO REMAIN <br />TYP <br />• <br />EXISTING CURB AND GUTTER <br />-EXISTING CURB AND GUTTER <br />EXISTING POLE MOUNTED LIGHT <br />FIXTURE TO REMAIN <br />EXISTING FIRE HYDRANT <br />Tfl BE REMOVED <br />EXISTING WATER <br />MANHOLE TO REMAIN <br />-EXISTING PARKING <br />STRIPING TO REMAIN <br />EXISTING CURB AND GL -TER <br />EXISTING TIMBER RETAINING <br />WALL AND CURB TO REMAIN <br />EXISTING LIGHT <br />FIXTURE TO REMAIN <br />EXISTING G ARB AND GUTTER <br />• <br />• <br />EXISTING LIGHT <br />FIXTURE TO REMAIN <br />General Landscape Plan Notes <br />I. ALL EXISTING LANDSCAPE MATERIALS TO REMAIN EXGEPT A5 <br />SPEC IFIGALLY REMOVED BY DEMOLITION OR NEW GONSTRUCTION. <br />2. PROTEGT ALL EXISTING LANDSCAPE MATERIALS BY FENGING OFF <br />AREAS OF THE SITE THAT SUPPORT EXISTING PLANT MATERIAL <br />3. ALL NEW TREES TO BE PLANTED WITH ROOT BALL SET AT FINAL <br />GRADE ELEVATION, AND WITH IRRIGATION "BASIN" IN AREAS THAT <br />RECEIVE DRIP IRRIGATION ONLY. PLANT ROOT BALL 3" HIGHER <br />THAN SURROUNDING GRADE IN AREAS THAT RECEIVE SPRAY <br />IRRIGATION. <br />4. SET ROOT BALL ON UNDISTURBED NATURAL SOIL AT BOTTOM OF <br />PLANT WELL. <br />5. MULGH TREES TO DRIPLINE IN TURF AREAS. <br />6. WRAP ALL NEW TREE TRUNKS FOR ONE SEASON - FROM FINISHED <br />GRADE TO 6' ABOVE GRADE OR TO FIRST BRANGH - ONLY FOR <br />TREES PLANTED IN THE FALL. <br />1. ALL NEW PLANTINGS TO BE ZONE 5, 6 HARDY <br />8. ALL NEW PLANTINGS TO RECEIVE DRIP IRRIGATION SYSTEM <br />q. EXISTING IRRIGATION SYSTEM VALVES AND CONTROLS TO BE <br />RELOGATED, TESTED TO PROVIDE SUITABLE COVERAGE FOR THE <br />HEALTH OF THE PLANTINGS AND FOR WATER CONSERVATION. <br />Planting schedule <br />A NOT USED <br />B <br />c <br />D <br />E <br />F <br />G <br />JAPANESE RED MAPLE <br />AGER PALMATUM ATROPURPUREUM <br />HANGOGK GORALBERRY <br />SYMPHORAGARPOS GHENAULTI' <br />GOMPAGT BURNING BUSH <br />EUONYMUS ALATUS GOMPAGTA <br />NOT USED <br />SPECIES <br />QTY QTY SIZE <br />TEXAS BLUEBELLS <br />EUSTOMA EXALTUM 55P. 'RUSSELLIANUM <br />FIRE KING GROGOSMIA <br />GROGOSMIA X GROGOSMIIFLORA ' FIRE KING' <br />H FIREFLY GORAL BELLS <br />1 HEUGHERA SANGUINEA 'FIREFLY' <br />1 1 SNOW IN SUMMER <br />GERASTIUM TOMENTOSUM <br />0 <br />2 I" DBH <br />3 5 gal <br />5 5 gaI <br />6 I gaI <br />6 BULBS <br />5 I GAL <br />-1 IGAL <br />EXISTING TREE TO REMAIN - PROTECT FROM DAMAGE <br />EXISTING TIMBER <br />RETAINING WALL TO <br />REMAIN <br />Trash And Rec.ycliig <br />i.' <br />PIPE BOLLARr <br />8'-8" <br />Trash Enclosure <br />1/4" - I'-0" <br />F <br />4" SOLID GMU GAP <br />8" REINF. GMU <br />HALL (RE: STRUGT) <br />CONCRETE ENCLOSURE PAD <br />(RE: STRUCTURAL) <br />8'-0" <br />General Site Plan Notes <br />I. GGTV CAMERA LOCATIONS TO BE DETERMINED, WITH GGTV <br />TERMINAL UNITS BEING MOUNTED IN VISUALLY UNOBTRUSIVE <br />POSITIONS AND PHYSICALLY INAGGE55IBLE <br />2. SITE UTILITIES TO BE DESIGNED AND DETAILED PER SEPARATE <br />GIVIL ENGINEERING. <br />3. ALL NEW EXTERIOR CONCRETE WALKWAYS TO BE 4"t., MILDLY <br />REINFORCED W/ #3 © 24" EA. WAY, AND WITH CONTROL JOINTS AT <br />4' OG MAXIMUM. <br />4. ALL WALKWAYS TO SLOPE AT A MAXIMUM PITCH OF 1:20. <br />5. NEW DRIVEWAY CONCRETE TO MATGH EXISTING DRIVEWAY <br />CONCRETE, SAVE FOR THE GRAGKS. <br />6. PAINTED STEEL BOLLARDS AS NEGESSARY TO REDUCE THE <br />POTENTIAL FOR BUILDING DAMAGE RESULTING FROM VEHICLE <br />IMPACT. <br />1. EXISTING TREES AND OTHER LANDSCAPE AND HARDSGAPE <br />FEATURES ARE TO REMAIN UNLESS NOTED OTHERWISE. <br />8. ALL NEW PLANTING BEDS TO REGEIVE ORGANIC SOIL AMENDMENTS <br />PRIOR TO PLANTING AT A RATE OF I GY ORGANIC MATERIAL PER <br />100 SF OF PLANTING BED SURFAGE AREA. <br />1. ALL EXISTING MATERIALS AND EQUIPMENT THAT ARE <br />SALVAGEABLE ARE TO BE DELIVERED TO SALVAGE YARD FOR <br />RESALE. <br />10. ALL REGYGLEABLE MATERIALS (LUMBER GUTTINGS, ETAL, <br />CARDBOARD) TO BE SEPARATELY COLLECTED AND DELIVERED <br />TO RESOURCE RECLAMATION 51TE. <br />II. ALL NEW EXTERIOR SITE AND BUILDING LIGHTING TO BE DOWNGAST <br />12. NEN EXTERIOR FINISHES TO MATCH EXISTING EXTERIOR FINISHES <br />AS APPROPRIATE (ES - SPLIT FACED GONGRETE BLOCK). <br />CONCRETE MASONRY <br />UNITS WITH SOLID CAP <br />❑2 CORRUGATED METAL SIDING <br />TO MATCH PORTION OF <br />MAIN BUILDING, IN WELDED <br />STEEL ANGLE FRAME <br />42"h. PAINTED STEEL <br />CONCRETE FILLED <br />BOLLARDS <br />® SOLID, SCORED <br />CONCRETE <br />MASONRY CAP <br />PIPE BOLLARD <br />SLOPE <br />-4 <br />ENCLOSURE PAD" <br />(RE:STRUCTURAL) <br />d <br />it <br />GONG. DRIVE/APRON <br />SLAB PER PLAN <br />Typical CMU <br />Enclosure Section <br />1/4" - I'-0" <br />Kyle <br />Callahan 6, <br />Associates <br />Architecture <br />0 <br />~� N <br />0 <br />0 <br />N <br />0 <br />.4:71O o <br />c� c <br />NiczEc�ki) <br />(.) O <br />N <br />Q <br />IMOMMINIa <br />vJ � <br />0 <br />Issue Date <br />Purpose <br />08/03/17 Initial Submission <br />12/06/2017 Revised per City of <br />Louisville comments <br /><> 02/13/2018 Final SRU <br />C <br />Sheet Content <br />LARGE SCALE REVISED <br />SITE PLAN AND NEW <br />LANDSCAPING PLAN <br />