My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Building Code Board of Appeals Agenda and Packet 1999
PORTAL
>
BOARDS COMMISSIONS COMMITTEES RECORDS (20.000)
>
BUILDING CODE BOARD OF APPEALS
>
1996-1999 Building Code Board of Appeals Agendas and Packets
>
1999 Building Code Board of Appeals Agendas and Packets
>
Building Code Board of Appeals Agenda and Packet 1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 2:01:12 PM
Creation date
10/4/2018 10:44:05 AM
Metadata
Fields
Template:
City Council Records
Doc Type
Boards Commissions Committees Records
Supplemental fields
Test
BCBOAPKT 1999
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
final sentence to read as follows : <br /> Standpipe traps shall not be located below <br /> the floor. <br /> 38 . Section 901 . 6 is deleted in its entirety. <br /> 39 Section 904 . 1 is amended by the deletion of <br /> the brackets and insertion of 6 inches and <br /> 152 .4 mm4 . <br /> 40 . Section 904. 6 is deleted in its entirety. <br /> 41 Section 905. 1 is amended by the deletion of <br /> the exception set forth in such section <br /> 42 . Section 905 6 is amended to read as follows <br /> 905 . 6 Side inlet quarter bends are <br /> prohibited. <br /> 43 Table 906 1 is amended to read as follows . <br /> Table 906.1 <br /> Horizontal Distance of Trap Arms <br /> (Except for water closets and similar fixtures) * <br /> DISTANCE <br /> TRAP ARM TRAP TO VENT <br /> Inches Feet Inches <br /> 1-1/4 2 6 <br /> 1-1/2 3 6 <br /> 2 5 0 <br /> 3 6 0 <br /> 4&larger 10 0 <br /> Slope one-fourth (1/4) inch per foot <br /> *The developed length between the trap of a water closet or similar fixture (measured <br /> from the top of the closet ring [closet flange] to the inner edge of the vent) and its <br /> vent shall not exceed six (6) feet <br /> 44 . Section 910 is deleted in its entirety. <br /> 45 Table 910. 4 is deleted in its entirety <br /> 46 Section 911 is deleted in its entirety <br /> 47 Section 912 is deleted in its entirety. <br /> 48 . Table 912.3 is deleted in its entirety. <br /> 49 . Section 913 .2 is amended by addition of a <br /> new final sentence to read as follows : A <br /> foot vent with a cleanout shall be installed <br /> immediately above the junction of the island <br /> fixture vent and drain. <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.