My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Planning Commission Minutes 2017 06 08
PORTAL
>
BOARDS COMMISSIONS COMMITTEES RECORDS (20.000)
>
PLANNING COMMISSION
>
2000-2019 Planning Commission
>
2017 Planning Commission Agendas Packets Minutes
>
Planning Commission Minutes 2017 06 08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/9/2020 1:29:07 PM
Creation date
7/9/2020 11:46:11 AM
Metadata
Fields
Template:
City Council Records
Meeting Date
6/8/2017
Doc Type
Boards Commissions Committees Records
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Planning Commission <br />Meeting Minutes <br />June 8, 2017 <br />Page 7 of 27 <br />o Vehicular <br />■ Nighthawk Circle (minor access) <br />■ Two main accesses off Via Appia <br />■ Maintain alignment <br />o Pedestrian <br />■ Trail connections from the south and west <br />■ Sidewalk off Via Appia <br />■ Maintain and redo the connections <br />■ Staff adding Condition to add new sidewalk along tennis courts, retaining walls <br />may be necessary as well as railings to get connection <br />PARKING <br />o No parking standards in the CDDSG, reviewing based on like facilities <br />o Parking expansion to the south and east, challenging topography <br />o Existing parking — 197 Spaces <br />0 3 spaces/1,000 sq. ft. <br />o Proposed expanded parking — 290 Spaces <br />0 2.9 spaces/1,000 sq. ft. <br />BICYCLES <br />o Existing parking — 35 Spaces <br />o Proposed parking — 68 Spaces <br />PATIO AND POOLS <br />o Outdoor pools versus indoor pools, pool will open up to patio <br />o Relocate playground equipment <br />o Grading will require significant retaining walls on south and east <br />o CDDSG states anything over 30" needs to be tiered and landscape hedges or <br />railings, meet all standards <br />o Multiple tiers as high as 5' with significant landscaping to buffer the walls <br />DUMPSTER ENCLOSURE <br />o New dumpster enclosure with proposed landscaping screening compliant with <br />CDDSG <br />• LIGHTING <br />o Replace and reduce light pole height <br />o Full cut off fixtures <br />o Back shields on south side/screen with evergreen trees <br />o Dim lights after hours <br />o Internal lights off after hours <br />Height <br />• Maximum allowed height: 35' to roofline/42' to mechanical screen <br />• Proposed height: 344" to roofline/36' to mechanical screen <br />Building Setbacks <br />• Minimum setbacks: 50' to north property line and 25' from other property lines <br />• Proposed setback (new building):116' minimum <br />• Existing structure non -conforming: 32' setback from north property line <br />Waiver Requests <br />• Street Tree and Shrub Requirement — 1 tree/40' between sidewalk and street: 20 <br />required <br />o Proposal is to maintain current condition — 4 trees at east end of lot <br />• Landscape Medians — landscape median every other bay: 2 required <br />o Proposal is to provide one island between bays <br />...the development plan contains areas allocated for usable open space in common park area in <br />excess of public use dedication requirements or that the modification or waiver is warranted by <br />the design and amenities incorporated in the development plan.... <br />Plat <br />
The URL can be used to link to this page
Your browser does not support the video tag.