Laserfiche WebLink
Heated slab on grade <br />R-15 for 4 ft + R-5 under full <br />slab <br />Fenestration U-Factor <br />.30 <br />Fenestration SHGC <br />.33 <br />Skylight U-Factor <br />.50 <br />Skylight SHGC <br />.40 <br />61. Section R406.3.1 On -site renewables are not included, is deleted in its <br />entirety. <br />62. Section R406.3.2 On -site renewables are included, is deleted in its <br />entirety. <br />63. Section R406.3.2 Tropical Climate Region Compliance Path, is deleted <br />in its entirety. <br />64. Section R505.1 General, is hereby amended to read as follows: <br />Section R505.1 General. <br />65. Section R505.1.1 Unconditioned space, is hereby deleted and replaced <br />with the following: <br />R505.1.1 Unconditioned space. Any unconditioned or low -energy space <br />that is altered to become a conditioned space shall comply with £eetien <br />Section R503. <br />Sec.15.18.040. — Design criteria. <br />All new heated commercial and residential heated structures shall meet the <br />following design criteria: <br />Snow load: 30 pounds per square foot. <br />18 <br />