My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Building Code Board of Appeals Agenda and Packet 2021 09 08
PORTAL
>
BOARDS COMMISSIONS COMMITTEES RECORDS (20.000)
>
BUILDING CODE BOARD OF APPEALS
>
2021 Building Code Board of Appeals Agendas and Packets
>
Building Code Board of Appeals Agenda and Packet 2021 09 08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/9/2021 5:09:24 PM
Creation date
9/9/2021 9:57:40 AM
Metadata
Fields
Template:
City Council Records
Meeting Date
9/8/2021
Doc Type
Boards Commissions Committees Records
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2. <br />Wind speed: <br />a. 145 miles per hour three second gust ASCE-7-10; <br />b. ASTM D3161 test with Class F Application. <br />3. <br />Wind exposure: "C", unless in the opinion of the Chief Building <br />Official greater <br />restrictions are needed to protect public safety. <br />4. <br />Seismic zone: B. <br />5. <br />Frost line depth: 36 inches below finished grade. <br />6. <br />Weathering: Severe — Climate Zone 5B. <br />7. <br />Termite: Slight. <br />8. <br />Decay: Slight. <br />9. <br />Winter design temperature: one degree. <br />10. <br />Anticipated snow: six inches. <br />11. <br />Ice and water shield: required on all shingled roofs — eaves only. <br />Shields must extend from the lowest edges to a point at least 24 inches inside the <br />exterior wall <br />line of the building. <br />12. <br />Drip edge: required on both eaves and rakes of roof. <br />13. <br />Air freezing index: less than 1000. <br />14. <br />Mean annual temperature: 47 degrees. <br />15. <br />Elevation: 5,337 feet above sea level. <br />16. <br />Sump pumps: <br />a. Cannot drain into sanitary or storm sewer; <br />b. Must daylight into lawn away from foundation; <br />C. Perimeter foundation systems must drain into sump pit and <br />then sump pump, and sump pump must drain into lawn. <br />19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.