Laserfiche WebLink
34. <br /> <br />35. <br /> <br />36. <br /> <br />to function independently in case of mechanical failure except that <br />single-family residential occupancies may have single pump if an <br />approved sensor and alarm system is installed." <br /> <br />Section 712.4.1 is amended by the deletion of the exception set <br />forth in such section. <br /> <br />Section 714 is deleted in its entirety. <br /> <br />Section 802 is amended by addition of a new final sentence to <br />read as follows: "Standpipe traps shall not be located below the <br />floor." <br /> <br />38. Section 904.1 is amended by the deletion of the brackets and <br /> insertion of "6 inches and 152.4 mm". <br /> <br />39. Section 904.6 is deleted in its entirety. <br /> <br />40. Section 905.1 is amended by the deletion of the exception set <br /> forth in such section. <br /> <br />41. Section 905.6 is amended to read as follows: <br /> 905.6 Side inlet quarter bends are prohibited. <br /> <br />42. Table 906.1 is amended to read as follows: <br /> <br /> Table 906.1 <br /> Horizontal Distance of Trap Arms <br /> (Except for water closets and similar fixtures)* <br /> <br /> DISTANCE <br />TRAP ARM TRAP TO VENT <br />Inches Feet Inches <br />1-1/4 2 6 <br />1-1/2 3 6 <br />2 5 0 <br />3 6 0 <br />4&larger 10 0 <br /> <br />Slope one-fourth (1/4) inch per foot. <br /> <br />*The developed length between the trap of a water closet or similar fixture (measured from the top of the closet ring [closet <br />flange] to the inner edge of the vent) and its vent shall not exceed six (6) feet. <br /> <br /> 43. Section 910 is deleted in its entirety. <br /> <br /> 44. Table 910.4 is deleted in its entirety. <br /> <br /> <br />