My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
City Council Study Session Agenda and Packet 2010 07 13
PORTAL
>
CITY COUNCIL RECORDS
>
STUDY SESSIONS (45.010)
>
2010-2019 City Council Study Sessions
>
2010 City Council Study Sessions
>
City Council Study Session Agenda and Packet 2010 07 13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2019 11:40:51 AM
Creation date
7/15/2010 9:24:26 AM
Metadata
Fields
Template:
CITYWIDE
Original Hardcopy Storage
6E1
Supplemental fields
Test
SSAGPKT 2010 07 13
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Wall (Flush <br />Mounted) <br />• 1.25 SF per 1' of tenant frontage <br />Projection - 15" <br />Copy Area: Single line of copy: 24" max; Multiple lines <br />of copy: 32" max. <br />Height — Roof Line, or windowsill of the 2 story; <br />Length: Cannot exceed 70% of total wall length per <br />tenant space <br />• Signs should be positioned within architectural features such as the panels above storefronts, on the transom, or <br />flanking doorways <br />• Signs should align with others on a block to maintain established patterns <br />Projecting & <br />Hanging <br />Awning Signs <br />• 1 SF of sign area for every linear foot of awning length <br />• One awning sign per building <br />Projection - More than 15 ", up to 3' <br />Clearance - 8' min. <br />• Should be mounted to align with top edge of transom and fit the dimensions of an opening to emphasize <br />proportions. It should not obscure ornamental details <br />• Should align with others on the block <br />• Color should coordinate with the color scheme of entire building <br />Monument • Not allowed <br />Freestanding • Not allowed <br />Window • 4 SF, less than 25% of an architecturally significant window Height — 25' max. <br />Menu Box <br />• Allowed, not defined <br />Sandwich Board • Not allowed <br />Marquee <br />• 1.25 SF per 1' of tenant frontage <br />• Must be easily removable as determined by the building <br />department <br />Projection - More than 15 ", up to 3' <br />Copy Area: Single line of copy: 24" max; Multiple lines <br />of copy: 32" max. <br />Height — Roof Line, up to 25' <br />Length: Cannot exceed 70% of total wall length per <br />tenant space <br />• Signs should be positioned within architectural features such as the panels above storefronts, on the transom, or <br />flanking doorways <br />• Signs should align with others on a block to maintain established patterns <br />Vendor <br />Kiosk • Special review, public ownership only <br />Mural <br />Landmark Signs <br />• Not defined <br />• Continuation or restoration of nonconforming sign that has been damaged by fire, flood, wind or other calamity or act of God may be restored to its original condition <br />Design & <br />Materials <br />• Sign materials should be durable and easy to maintain <br />• Appropriate sign materials include painted or carved wood; carved wooden letters; epoxy letters; galvanized sheet metal; slate, marble, or sandstone; gold leaf; gilt, painted, stained, or sandblasted glass; clear and colored acrylic; neon; or <br />stained glass <br />Message <br />Size <br />• The lesser of 1 SF of sign area for each linear foot of frontage of <br />the building, or 18 SF per sign, with no face of the sign <br />exceeding 9 SF <br />• Allowed by special review, sign requirements not defined <br />• No considerations <br />Overview of Sign Code - Downtown Boulder <br />Placement Considerations <br />Projection - More than 15 ", up to 3' <br />Clearance - 8' min. <br />Height - 12' <br />Spacing - 25' min. (one per building face) <br />6 <br />• Any end panel on a projecting sign is considered a face of the sign and included in the area of that sign if the end <br />panel is 12 ", or more in width <br />• Signs projecting over private property may not project more than six feet from a wall of a building nor beyond the <br />minimum required building setback line and may not exceed 24 SF in total area, and no face of a sign shall exceed <br />12 SF <br />• No considerations <br />• Lettering styles should be proportioned, simple, and easy to read <br />• A simple typeface is preferred over a faddish or overly ornate type style <br />• The number of type styles should be limited to two per sign. As a general rule, the letter forms should occupy not more than 75% of the total sign panel <br />Illumination <br />• Signs that move, twinkle, rotate, pulsate or appear to have motion are prohibited <br />• Lighting external to the sign surface with illumination directed toward the sign is preferred <br />• Internally lit signs are prohibited <br />• The light level should not overpower the facade or other signs on the street <br />• The light source should be shielded from pedestrian view <br />• If the sign is illuminated by neon, it does not exceed four square feet in area <br />
The URL can be used to link to this page
Your browser does not support the video tag.