Within the Hospital Parcel, the applicant <br />proposes the establishment of three building <br />height zones with minimum setbacks and <br />building massing design standards. The three <br />height zones are for three-story, four-story, and <br />five -story buildings. The standards include <br />different maximum heights for the buildings, the <br />parapets, and mechanical screen structures as <br />noted in Figure 9 below. Due to some of the <br />unique requirements for hospital and medical <br />office developments, the proposed maximum <br />heights are taller than what would be expected <br />in non -medical office buildings. <br />The proposed building massing design <br />standards would require building step -backs of <br />15 feet for building elements above 45' and <br />limit the footprint of building elements above <br />45' to 5013/0 of the lower building footprint. This <br />is intended to moderate the visual impacts of <br />the building massing for taller buildings. The <br />proposed standards also include allowances for architectural projections and "defining <br />architectural elements," including requirements for depth variations for these elements. <br />Rooftop enclosures would need to be set back an additional 10' from the edge of the <br />buildings. <br />Figure 9: Proposed Height and Massing Standards <br />Figure 8: Hospital Parcel Height Zones <br />., <br />•• PROPERTY LINE <br />• <br />• <br />• <br />▪ • <br />•• SECONDARY <br />•• ENTRY <br />4. # POURSTORr <br />HOSPITAL t I zoNF <br />PARCEL <br />• <br />Illlllf/f►!!l,,$• !ram <br />:CEL ENERGY ��, <br />•UBSTATION <br />THREE <br />STORY <br />ZONE <br />FINE STORY <br />ZONE <br />I►rNnnu <br />ENTRY <br />CITY OF LOUJ ILLE <br />CITY & COUNTY OF BROOMFIELD <br />HOSPITAL PARCEL <br />FOR THE HOSPITAL PARCEL {LOT 1, BLOCK 1) BUILDING HEIGHTS ARE EXPECTED TO RANGE FROM THREE TO FIVE OCCUPIABLE STORIES. RANGING IN HEIGHT FROM 50' TO EC. <br />UNOCCUPIEDMECHANICAL SCREENING OF UP TO 20' WOULD BE ABOVE THE 5 STORIES, THE HOSPITAL PARCEL WILL DE ZONED TO SUPPORT LOWER THREE-STORY BUILDING HEIGHTS <br />TOWARDS THE NORTH. EAST, AND WEST PROPERTY BOUNDARIES CONCENTRATING THE 5•STORY STRUCTURES CENTRALLY WITHIN THE SITE. REFER TO THE GRAPHIC FOR PARCEL <br />HEIGHT ZONES. <br />BUILDINGHEIGHT ZONING: <br />THREE STORY ZONE: <br />45'-0- MAXIMUM BUILDING HEIGHT <br />60'u• PARAPET HEIGHT <br />65'-0' MECHANICAL PENTHOUSE HEIGHT' <br />FOUR STORY ZONE, <br />60'-0• MAXIMUM BUILDING HEIGHT <br />65'•0• PARAPET HEIGHT <br />B0'-0• MECHANICAL PENTHOUSE HEIGHT' <br />FIVE STORY ZONE,. <br />65'-0• MAXIMUM BUILDING HEIGHT <br />80'-0- PARAPET HEIGHT <br />105'-0• MECHANICAL PENTHOUSE HEIGHT' <br />'ROOF ACCESS AND ELEVATOR OVERUN 15 EXCLUDED FROM THE BUILDING HEIGHT <br />BUILDING MASSING DESIGN PARAMETERS, <br />FOR BUILDING FACADES EXCEEDING 100 FEET IN LENGTH AND MORE THAN 45 FT N HEIGHT. A RELIEF IN THE BUILDING MASSING 15 REQUIRED TO REDUCE VISUAL MONOTONY AND <br />ENHANCE ARCHITECTURAL INTEREST, <br />• A MAXIMUM HEIGHT OF 45 FEET IS PERMITTED BEFORE A MINIMUM HORIZONTAL SETBACK OF 15 FEET 15 REOUIRED FROM THE PRIMARY BUILDING FACE. <br />• A PROJECTED RELIEF ELEMENT MAY EXTEND OUTWARD FROM THE MAIN BUILDING MASS BY A MINIMUM OF 2 FEET. PROVIDED IT CONTRIBUTES <br />TO THE OVERALL ARTICULATION AND DESIGN OF THE FACADE. <br />•THE FOOTPRINT OF EACH FLOOR ABOVE 45 FEET SHALL NOT EXCEED 52% OF THE FOOTPRINT OF THE BUILDING AT OR BELOW 45 FEET. <br />• ANY ROOFTOP ENCLOSURE IE. G.. MECHANICAL PENTHOUSES) MUST BE SET BACK A MINIMUM OF 10 FEET FROM THE EDGE OF THE BUILDING MASS. UNLESS IT 15 <br />ARCHITECTURALLY INTEGRATED INTO THE OVERALL DESIGN OF THE BUILDING. <br />•EXCEPTION: A DEFINING ARCHITECTURAL ELEMENT OR DISTINCT BUILDING FORM WITH A TOTAL WIDTH OF LESS THAN 100 FEET IS EXEMPT FROM THE ABOVE SETBACK AND <br />RELIEF REQUIREMENTS. A MINIMUM 2-FOOT DEPTH VARIATION FROM THE ADJACENT PRIMARY FACADE PLANE MUST STILL BE PROVIDED TO ENSURE VISUAL ARTICULATION. <br />DEFINING ARCHITECTURAL ELEMENTS MAY INCLUDE. BUT ARE NOT LIMITED TO: <br />-VERTICAL CIRCULATION TOWERS (E.G., STAIR OR ELEVATOR CORES) <br />-ENTRY PAVILIONS OR LOBBIES <br />-ARCHITECTURAL EYEBROWS OR RODE OVERHANGS <br />-BRANDED OR SCULPTURAL FACADE FEATURES <br />-CORNER ELEMENTS OR TURRETS <br />-ATRIUM VOLUMES OR LIGHT WELLS <br />-DISTINCTIVE ROOF FORMS <br />9 <br />