My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Louisville Corporate Campus at CTC PUD Amendment 2 Mylar
PORTAL
>
RECORDED PLATS (Mylars) and CITY MAPS
>
PUD (Planned Unit Developments)
>
L
>
Louisville Corporate Campus at CTC PUD Amendment 2 Mylar
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2025 5:48:15 PM
Creation date
10/15/2025 5:25:48 PM
Metadata
Fields
Template:
CITYWIDE
Doc Type
Mylar
Ord/Res - Year
2025
Ord/Res - Number
47
Recordation Number
4105841
Subdivision Name
Louisville Corporate Campus at CTC
Signed Date
7/8/2025
Parties Involved
SREIT 600 Tech Court LLC
Record Series Code
40.180
Record Series Name
Maps Drawings Plats Plans
Quality Check
10/15/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
041 341 10/15/2025 03.35 PM <br />RF: $43_ 00 Page 1 of 9 <br />Electronically recorded in Boulder County Colorado. Recorded as received. <br />PROJECT SUMMARY <br />TOTAL LAND AREA: <br />BUILDING AREA: <br />TOTAL LOT 2 AREA COVERAGE <br />OF PROPOSED CARPORTS: <br />STORAGE TANK HEIGHT: <br />CARPORT CANOPY HEIGHT: <br />LOT 2, BUILDING C SETBACKS <br />AFFECTED BY AMENDMENT: <br />LOT 2, BUILDING C PARKING: <br />GENERAL NOTES <br />1. <br />NO CHANGES PROPOSED <br />NO CHANGES PROPOSED <br />33,489 SF CARPORT COVERAGE (APPDX. 197 SPACES COVERED) <br />45.00 FEET <br />28.00 FEET <br />REAR YARD ABUTTING A SIMILAR ZONE DISTRICT <br />ALLOWABLE: 15 FEET <br />PROPOSED: 70 FEET <br />EXISTING TO REMAIN: <br />STANDARD: <br />HANDICAP: <br />TOTAL <br />EXISTING PARKING TO <br />STANDARD: <br />HANDICAP: <br />TOTAL <br />THE PROPERTY IS ZONED I -INDUSTRIAL. <br />318 SPACES <br />9 SPACES <br />327 SPACES <br />BE COVERED BY SOLAR CARPORTS: <br />93 SPACES <br />6 SPACES <br />99 SPACES <br />2. ALL SETBACKS AND LAND USE REQUIREMENTS SHALL CONFORM TO THE CITY <br />OF LOUISVILLE, COLORADO ZONING AND LAND USE REGULATIONS IN EFFECT <br />AS OF THE DATE OF APPROVAL OF THIS PLANNED UNIT DEVELOPMENT BY THE <br />CITY OF LOUISVILLE, COLORADO. <br />3. THE CITY OF LOUISVILLE IS NOT RESPONSIBLE FOR DAMAGE TO OR REPAIR OF <br />MONUMENT SIGNS DUE TO UTILITY MAINTENANCE. <br />4. THE CITY OF LOUISVILLE IS NOT RESPONSIBLE FOR DAMAGE TO PAVEMENT <br />SURFACES OR LANDSCAPING CAUSED DURING REPAIR OR MAINTENANCE <br />ACTIVITIES OF UTILITIES LOCATED WITHIN PUBLIC UTILITY EASEMENTS. <br />5. SIGNS FOR THIS LOT HAVE BEEN APPROVED BY ALL OWNERS TO FOLLOW <br />SIGN CODE. <br />LOUISVILLE CORPORATE CAMPUS AT CTC <br />PLANNED UNIT DEVELOPMENT AMENDMENT #2 <br />LOCATED IN THE SOUTHEAST QUARTER OF SECTION 16, <br />TOWNSHIP 1 SOUTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO <br />SHEET INDEX <br />1 OF 9 COVER SHEET <br />2 OF 9 UTILITY PLAN <br />3 OF 9 GRADING PLAN <br />4 OF 9 BUILDING "C" FLOOR PLAN <br />5 OF 9 BUILDING "C" SOUTH ELEVATION <br />6 OF 9 BUILDING "C" WEST & EAST ELEVATIONS <br />7 OF 9 BUILDING "C" NORTH ELEVATION <br />8 OF 9 LANDSCAPE PLAN <br />9 OF 9 LANDSCAPE PLAN <br />LEGAL DESCRIPTION: <br />LOT 1, 2 & 3 OF THE LOUISVILLE CORPORATE CAMPUS AT CTC, REPLAT A._ <br />AMENDMENT PROJECT DESCRIPTION: <br />THIS AMENDMENT INCLUDES THE FOLLOWING CHANGES FROM THE <br />APPROVED PUD: <br />1. LOT 2 - CONSTRUCT PARKING SPACE SHADE/SOLAR SHELTERS. <br />2. LOT 2 - EXPANDING EXISTING SCREENED EQUIPMENT YARDS. <br />3. LOT 2 - INSTALLATION OF EXTERIOR 45 FOOT HEIGHT WHITE <br />CYLINDRICAL STORAGE TANKS IN SCREENED EQUIPMENT <br />YARDS. <br />4. LOT 2 - UPDATE AND INSTALL NEW SIGNAGE FOR FULL BUILDING <br />TENANT. <br />WAIVER REQUESTS: <br />1. REQUEST FOR THE HEIGHT OF TWO STORAGE TANKS TO BE 45 <br />FEET TALL. <br />2. REQUEST FOR WALL SIGN TO BE 4 FEET TALL, EXCEEDING THE <br />MAXIMUM HEIGHT OF 3 FEET IN THE SIGN CODE. <br />3. REQUEST TO EXCEED ACCESSORY STRUCTURE HEIGHT OF <br />25 FEET FOR REAR SOLAR CANOPIES. <br />4. REQUEST TO ALLOW ACCESSORY STRUCTURE FRONT SETBACK <br />TO 10 FEET INSTEAD OF 30 FEET. <br />LOUISVILLE <br />STATE HIGHWAY42 <br />TAYLOR AVE. <br />PRAIRIE WAYQ <br />S. 96TH ST. <br />DILLON ROAD <br />VICINITY MAP <br />CHERRY ST. <br />S. 104TH ST. <br />SITE <br />NORTH <br />71QINTERGROUP <br />ARCHIMCTS <br />112000 West Littleton Blvd. Littleton, CO 80120 <br />■ P. 303.738.8877 ■ F. 303.738.2294 • igarch.com <br />OWNERSHIP SIGNATURE BLOCK: <br />BY SIGNING THIS ANAL PUD, THE OWNER ACKNOWLEDGES AND ACCEPTS ALL THE <br />REQUIREMENTS AND INTENT SET FORTH IN THIS FINAL PUD. WITNESS MY HAND <br />AND SEAL THIS DAY OF , 20_. <br />OWNER: <br />site 1S (ontt TE'C-N Co.) a.T, .*,c <br />3 <br />BY: �il� G /! 5 /z <br />PICIGE z R ex TOLCH (N DATE <br />MANAGER Avi-Hoe2St61 °IT " <br />CHERYL MERIL 1 <br />COMM. # 2499164 <br />SAN FRANCISCO COUNTY <br />NOTARY PUBLIC-CAL1FOR IAZ <br />MY COMMISSION EXPIRES h <br />OCTOB£R 03. 2028 <br />V er. <br />NOTARY NAME (PRINT) <br />LA/ <br />IS, D.S. <br />NOTARY SIGNATURE \ DATE <br />WITNESS MY HAND AND OFFICIAL SEAL <br />MY COMMISSION EXPIRES ICl/A %o1 rCl <br />PLANNING COMMISION CERTIFICATE: <br />RECOMMENDED APPROVAL THIS 1 2th DAY OF June <br />COMMISSION OF THE CITY OF LOUISVILLE, COLORADO. <br />RESOLUTION NO. 9 SERIES 2025 <br />CITY COUNCIL CERTIFICATE: <br />APPROVED THIS 8th DAY OF July <br />CITY OF LOUISVILLE, COLORADO. <br />RESOLUTINO. 47 SERIES 2025 <br />, 2025EY THE PLANNING <br />, 2025 BY THE CITY COUNCIL OF THE <br />PUD DATE APPROVED <br />LOUISVILLE CORPORATE CAMPUS PUD NOV. 17, 2015 <br />ALTERNATIVE #1 <br />LOUISVILLE CORPORATE CAMPUS PUD NOV. 17, 2015 <br />ALTERNATIVE #2 <br />LOUISVILLE CORPORATE CAMPUS PUD FEB. 18, 2019 <br />ALTERNATIVE #1, AMENDMENT #1 <br />LOUISVILLE CORPORATE CAMPUS PUD-------- <br />ALTERNATIVE #1, AMENDMENT#2 <br />DATE: <br />11.12.2024 P.U.D. AMEND <br />NOTE <br />THIE SITE BEING <br />DEVELOPED UNDER <br />THIS PUD <br />THE SITE IS NOT <br />DEVELOPED UNDER <br />THIS PUD <br />MINOR CHANGES <br />TO ARCHITECTURE, <br />PARKING, <br />LANDSCAPING AND <br />SITE DESIGN <br />BLDG C - PARKING <br />SHADE/SOLAR <br />STRUCT., <br />EXPANSION OF <br />EQUIP. YARD <br />ALTERNATIVE #1 <br />COVER SHEET <br />SHEET 1 OF 9 <br />SCALE: 1" = 2000'-0" <br />J <br />
The URL can be used to link to this page
Your browser does not support the video tag.