My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Louisville Corporate Campus at CTC PUD Amendment 2 Mylar
PORTAL
>
RECORDED PLATS (Mylars) and CITY MAPS
>
PUD (Planned Unit Developments)
>
L
>
Louisville Corporate Campus at CTC PUD Amendment 2 Mylar
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2025 5:48:15 PM
Creation date
10/15/2025 5:25:48 PM
Metadata
Fields
Template:
CITYWIDE
Doc Type
Mylar
Ord/Res - Year
2025
Ord/Res - Number
47
Recordation Number
4105841
Subdivision Name
Louisville Corporate Campus at CTC
Signed Date
7/8/2025
Parties Involved
SREIT 600 Tech Court LLC
Record Series Code
40.180
Record Series Name
Maps Drawings Plats Plans
Quality Check
10/15/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Boulder Countv. CO <br />04105841 <br />Page 2 of 9 <br />LAST SAVED: 3/18/2025 <br />A <br />° <br />- 0 <br />0 <br />0 <br />0 <br />G) <br />< <br />= Z <br />0 <br />_J <br />0 <br />EX.-12" w/L (PUBLIC) <br />0 <br />0 <br />0 5 0 <br />G7 <br />t - <br />0 <br />= <br />h 0 41- <br />x <br />0 <br />w <br />z <br />(1) <br />0 X <br />0 <br />DILLON SELF STORAGE <br />EXISTING WALL <br />_ . . <br />7- EX. 6 W/L <br />& FH <br />10.0' DRAINAGE <br />I & UTILITY ESMT <br />L <br />TRAFFIC <br />SIGNAL CONDUIT <br />TYPE 13 , <br />COMBO INLET -N <br />UTILITY <br />ESMT. <br />12" W/▪ L <br />12W <br />12W <br />OFF -SITE <br />POND OUTFALL <br />(PRIVATE) <br />12W 12W <br />24" HDPEP (PRIVATE) <br />12" HDPEP <br />TRENCH GRATE <br />— <br />TYPE 13 <br />I COMBO INLET <br />7 <br />6" W/L <br />& FH <br />o <br />; g <br />— <br />(PUBLIC) 5' TYPE 'R' INLET <br />(Tr — 5' TYPE 'R' INLET <br />5' TYPE <br />INLET. <br />11rj <br />C 1" IRR. TAP ----Ia.] <br />12W (puBLIC) <br />I 12W <br />L <br />OUTLOT 18" RCP (PUBLIC) <br />6" WA <br />0 <br />oft <br />0 <br />x <br />0 <br />4 <br />0 <br />EX, 48"x76" HERCP <br />YE. <br />0 <br />& FH <br />10.0DRAINAGE Se] <br />UllUTY ESMT <br />k._10.0' DRAINAGE & <br />PTILITY ESMT <br />o_ <br />0: <br />CC <br />CO <br />SIGNAL <br />IN <br />CONDUIT <br />11 <br />5' TYPE <br />'R' INLET <br />TYPE 13 <br />COMBO INLET <br />L <br />12" HDPEP <br />HDPEP <br />TYPE 13 <br />COMBO INLET <br />6" W/L & FH (PRIVATE) <br />1-4 <br />1 g <br />EX. 24" <br />F.E.S. <br />EX, 15' TYPE <br />'R' INLET <br />1, X <br />I <br />--- 5' TYPE <br />LOT 5 <br />OFF -SITE <br />DETENTION <br />Q100=4.6 CFS <br />Ed2- <br />LOT 6 <br />10.0' DRAINAGE <br />& U11LJTY ESMT <br />6" W/L & FH <br />12W <br />N <br />2" IRRIGATION METER <br />2" DOMESTIC METER <br />18" HDPEP <br />8" F/S o_ <br />-11 I <br />TRENCH GRATE <br />I I <br />LOUISVILLE CORPORATE CAMPUS AT CTC <br />PLANNED UNIT DEVELOPMENT <br />LOCATED IN THE SOUTHEAST QUARTER OF SECTION 16, <br />TOWNSHIP 1 sou-n-t, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, <br />CITY OF LOUISVILLE, COUNTY OF BOULDER, STATE OF COLORADO -re— \c <br />(PRIVATE) <br />12W 12W 12W <br />36" HDPEP (PRIVATE) <br />I I I I I I = <br />TRENCH GRATE <br />LOT 1 <br />(725 TECH COURT) <br />BLDG. B <br />v, <br />z <br />.7c-c <br />• <br />- cc <br />›- (./) <br />"co <br />5' TYPE <br />'R' INLET VI <br />- 3" DOMESTIC & — <br />C <br />2" IRRIGATION vs..1 <br />* <br />(PUBLIC) <br />12W 12W 12W 12W <br />TECH CT. 18" RCP (PUBLIC) <br />'R' INLET 7.0 <br />TYPE 13 <br />INLET <br />(PRIVATE) <br />8W 8W <br />18" HDPEP ' -1:.4 <br />TYPE 13 COMBO INLET -\443 <br />ILKi 12 HDPEP <br />II - <br />TYPE 13 INLET -/ <br />EXISTING <br />BUILDING <br />CONCRETE <br />8W <br />CLEANOUT <br />5' TYPE <br />'R' INLET <br />18" HDPEP <br />:EX. 6" WA <br />& FH <br />2W <br />8SAN <br />• • di <br />3" DOMESTIC & T <br />2" LANDSCAPE STUBS --r— <br />"co <br />12" HDPEP <br />5' TYPE 'R' INLET <br />10.0' DRAINAGE <br />& ESMT' <br />12W <br />36" HDPEP (PRIVATE) <br />4-4 <br />• 'NS: 4.. <br />‘-`• <br />.2.022020.42.0 <br />-co <br />0 Lo <br />12W 12Vi <br />6" W/L <br />& FH <br />co 7 <br />29"x45" HERCP <br />3 (PRIVATE) <br />-31J <br />a_ <br />co <br />.,] <br />-- <br />t <br />co <br />▪ 422aior <br />TYPE 13 <br />COMBO INLET <br />it <br />FOUNDATION 8c <br />CANOPY DRAIN <br />OUTFALLS <br />51 TYPE 'R' INLET <br />(PRIVATE) <br />18" PLUG <br />ri HDPEP (PRIVATE) <br />12W 12W 12W (PUBLIC)12W <br />sAC 8.7sAN 78.1AN EtS*1 <br />18" RCP (PUBLIC) <br />1 8'' RCP <br />1111 ..1111 .1 —1111 IIIIII1 II 1111 III <br />5' TYPE 'R' INLET (PUBLIC) =‘,7 <br />14"x23" HERCP <br />5' TYPE 'R' INLL <br />TYPE 13 <br />COMBO INLET <br />-2" IRRIGATION METER <br />-2" DOMESTIC METER <br />LOT 3 <br />(700 TECH COURT) <br />BLDG. A <br />8" FIRE <br />SERVICE <br />6" WA <br />& FH <br />8W 8W <br />18" HDPEP <br />TYPE 13 <br />COMBO INLET <br />SELF JOEL A <br />UNPLATTED <br />EX. 10' UTILITY EASMENT <br />8W <br />8W <br />CONCRETE <br />24" <br />(PUBLIC <br />8W <br />HDPEP <br />I—. <br />Li <br />• II I MN! I <br />12W <br />8SAN <br />18" RCP <br />(PUBLIC) <br />co <br />5' TYPE IR' INLET (PUBLIC) -11 <br />TYPE 13 COMBO INLET <br />1. DOUBLE <br />TYPE 13 <br />COMBO <br />INLET <br />6" WA 8c FH <br />(PRIVATE) <br />5' TYPE 'R' <br />INLET (PUBLIC) <br />24" RCP <br />•(PUBLIC) <br />.. I ....II II . .... I . .IIII.• . . ...I.I. I ' I., III. ..1 1 <br />c 18" HDPEP <br />II — I., <br />8W (PRIVATE) <br />8W 8W <br />TYPE 13 <br />COMBO INLET <br />EX. 30" RCP STUB <br />EX. UTILITY EASMENT <br />30" RCP (PUBLIC) <br />LOT 1 <br />LOT 2 <br />COLORADO TECHNOLOGICAL CENTER <br />FILING NO. 2 <br />EX. 36" RCP (PUBLIC) <br />'4 1 <br />24" HDPEP <br />TYPE 13 <br />COMBO INLET <br />6" WA <br />8c FH <br />30" <br />TYPE 13 <br />COMBO INLET <br />OUTFALL STRUCTURE <br />LOT 7 LOT 8 <br />FIRST FILING BLOCK 4 <br />COLORADO TECHNOLOGICAL CENTER <br />(PRIVATE) <br />12W 12W <br />10 <br />6" WA & FR:4' <br />8" HDPEP <br />LOT 2 <br />(600 TECH COURT) <br />BLDG. C <br />2" DOMESTIC METER <br />3" W/S <br />2" IRRIGATION METER <br />• 3" DOMESTIC 8c <br />2" LANDSCAPE STUBS <br />34"x53" HERCP <br />10.0' SURFACE <br />MAItITENACE ESMT <br />12" HDPEP <br />I 1 1 <br />TYPE 13 <br />COMBO <br />INLET <br />(PRIVATE) <br />36" F.E.S. <br />20.01 UTILJTY EASEMENT <br />.30 RCP (PUBLIC) <br />EX. 8" WA (PRIVATE) <br />12" WA <br />(PUBLIC) <br />42" F.E.S. <br />3 FT CONCRETE PAN <br />LOT 9 <br />10.0' DRAINAGE & UTILITY EASEMENT <br />EX. UTILITY <br />EASEMENT <br />CANOPY DRAIN & <br />• FOUNDATION DRAIN <br />OUTLETS <br />10.0' SURFACE <br />MAINTENANCE ESMT <br />-30.0' UTILITY ESMT <br />55.0' TEMP. ACCESS ESMT <br />6" W/L & <br />(PRIVATE) <br />TRACT A <br />DETENTION POND <br />LOT 4 <br />LOT 3 <br />EX. 8" WA (PRIVATE) <br />6" W/L <br />8c FH <br />70.6 <br />LOT 10 <br />•1=1111/ <br />LOT 11 <br />LEGEND <br />- 6w <br />- 8W <br />— 12W — <br />8SAN <br />Proposed 6" Waterline <br />Proposed 8" Waterline <br />Proposed 12" Waterline <br />Existing Waterline <br />Proposed 8" Sewerline <br />Existing Sewerline <br />Stormline <br />Water Service <br />SS Sewer Service <br />FS Fire Service <br />X— G --X- Existing Gas Line <br />- E --x- Ex. Underground Electric <br />- OHE Ex. Overhead Electric <br />FO Existing Fiber Optic <br />X T --X- Existing Telephone Line <br />- TV--X- Existing Cable TV Line <br />A Thrust Block <br />Water Valve <br />Fire Hydrant <br />Plug <br />Manhole <br />Type 'R' Inlet <br />Existing Contours <br />Proposed Contours <br />Street Light <br />Install Handicap Ramp <br />LOT 12 <br />F7RST PILING BLOCK 4 <br />COLORADO TECHNOLOGICAL CENTER <br />_El <br />36" HDPEP (PRIVATE) <br />6" WA & FH (PRIVATE) <br />EX. 12" WA (PUBLIC) <br />CO <br />0 <br />51.5' UTILITY ESMT <br />LOT 13 <br />LOT 15 <br />LOT 14 <br />0 60' 120' <br />SCALE: 1" = 60' <br />EX. 8" S/L (PUBLIC) <br />__ <br />_____ <br />LOT 16 EX. 12" W/L <br />• <br />4c <br />—EX. 20' UTILITY EASMENT <br />SCALE VERIFICATION <br />BAR IS ONE INCH <br />ON ORIGINAL DRAWING <br />11111.11.11111111111011 <br />IF NOT ONE INCH ON THIS SHEET <br />ADJUST SCALES ACCORDINGLY <br />03 <br />NO. <br />ADD TREES, REMOVE BASKETBALL & VOLLEYBALL DETAILS <br />Va" <br />00 <br />ADD SOLAR PANELS OVER PARKING & EQUIPMENT AT <br />BACK OF <br />LSD <br />CZ) <br />co <br />C:3 <br />JOS NUMER: <br />2601-2 <br />DATE <br />05/20/2025 <br />SCALE.: <br />1"=60' <br />SHEET NO: <br />2 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.